{"id":12063,"date":"2026-07-16T03:31:56","date_gmt":"2026-07-16T03:31:56","guid":{"rendered":"https:\/\/www.omch.com\/?p=12063"},"modified":"2026-07-16T03:31:58","modified_gmt":"2026-07-16T03:31:58","slug":"standard-din-rail-size","status":"publish","type":"post","link":"https:\/\/www.omch.com\/tr\/standard-din-rail-size\/","title":{"rendered":"Standart DIN Ray\u0131 Boyut K\u0131lavuzu \u2014 Tam Boyutlar, T\u00fcrler ve Se\u00e7im Tablosu"},"content":{"rendered":"<!DOCTYPE html>\n<html><head>\n  <meta charset=\"utf-8\">\n  <meta name=\"viewport\" content=\"width=device-width, initial-scale=1\">\n  <title>Standart DIN Ray\u0131 Boyut K\u0131lavuzu \u2014 Tam Boyutlar, T\u00fcrler ve Se\u00e7im Tablosu<\/title>\n<\/head>\n<body>\n<!-- \u2193\u2193\u2193 The deployable fragment begins here. \u2193\u2193\u2193 -->\n<div class=\"bd-post\">\n  <style>\n    @import url('https:\/\/fonts.googleapis.com\/css2?family=Manrope:wght@400;600;700&family=Roboto:wght@600;700&display=swap');\n\n    .bd-post {\n      --prose-width: 720px;\n      --gap-attach: 16px;\n      --gap-normal: 32px;\n      --gap-section: 48px;\n      --pad-compact: 16px;\n      --pad-standard: 24px;\n      \/* Color palette \u2014 all solid, from design-plan.md *\/\n      --body-bg: #FFFFFF;\n      --text-primary: #333333;\n      --text-secondary: #6E6E6E;\n      --text-accent: #1D6FB5;\n      --heading: #000000;\n      --inverse-bg: #1E1E1E;\n      --inverse-text: #FFFFFF;\n      --inverse-text-secondary: #B0B0B0;\n      --inverse-text-accent: #479DE2;\n      --accent: #479DE2;\n      --accent-text: #1D6FB5;\n      --accent-hot: #FD9649;\n      --card-fill: #EDF4FA;\n      --card-border: #E0E0E0;\n      --card-text: #333333;\n      --card-text-secondary: #6E6E6E;\n      --card-text-accent: #1D6FB5;\n      --panel-fill: #FAFAFA;\n      --table-th-bg: #C4D5E5;\n      --table-border: #D3D3D3;\n      --btn-white: #FFFFFF;\n      --btn-ink: #1E1E1E;\n\n      font-family: \"Manrope\", sans-serif;\n      font-size: 16px;\n      font-weight: 400;\n      line-height: 1.6;\n      color: var(--text-primary);\n      background: var(--body-bg);\n      padding: 40px;\n      max-width: 100%;\n      box-sizing: border-box;\n    }\n    .bd-post a { overflow-wrap: anywhere; word-break: break-word; }\n    .bd-post p a, .bd-post li a, .bd-post blockquote a, .bd-post td a {\n      color: var(--text-accent); text-decoration: underline;\n    }\n    .bd-post p, .bd-post li { overflow-wrap: break-word; }\n    .bd-post .bd-post-article { max-width: var(--prose-width); margin: 0 auto; }\n\n    \/* Prose spacing *\/\n    .bd-post p  { margin: 0 0 1em; }\n    .bd-post h1 { font-family: \"Roboto\", sans-serif; font-weight: 600; font-size: 34px; line-height: 1.2; color: var(--heading); margin: 0 0 16px; }\n    .bd-post h2 { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 34px; line-height: 1.2; color: var(--heading); margin: 48px 0 16px; }\n    .bd-post h3 { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 24px; line-height: 1.25; color: var(--heading); margin: 32px 0 12px; }\n    .bd-post ul, .bd-post ol { margin: 0 0 1em; padding-left: 1.5em; }\n    .bd-post li { margin-bottom: 0.5em; }\n    .bd-post strong { font-weight: 700; }\n    .bd-post ul ::marker { color: var(--accent); }\n\n    \/* Tables *\/\n    .bd-post .table-wrapper { overflow-x: auto; margin: 0 0 1em; }\n    .bd-post table { width: 100%; border-collapse: collapse; font-size: 14px; }\n    .bd-post th { background: var(--table-th-bg); color: var(--text-primary); font-family: \"Roboto\", sans-serif; font-weight: 600; padding: 10px 12px; text-align: left; }\n    .bd-post td { padding: 8px 12px; border-bottom: 1px solid var(--table-border); }\n    .bd-post tr:hover td { background: var(--card-fill); }\n\n    \/* Blockquote *\/\n    .bd-post blockquote { border-left: 4px solid var(--accent); margin: 0 0 1em; padding: 8px 0 8px 20px; font-style: italic; color: var(--text-primary); }\n\n    \/* box-sizing reset *\/\n    .bd-post [class*=\"bp-\"] { box-sizing: border-box; }\n\n    \/* BP outer margins \u2014 direct children only *\/\n    .bd-post .bd-post-article > .bp-stat-callout { margin: var(--gap-attach) 0 var(--gap-normal); }\n    .bd-post .bd-post-article > .bp-material-card { margin: var(--gap-normal) 0; }\n    .bd-post .bd-post-article > .bp-checklist-card { margin: var(--gap-normal) 0; }\n    .bd-post .bd-post-article > .bp-cta-end { margin: var(--gap-section) 0 0; }\n\n    \/* BP-1: Stat Callout (low, attach-prev, compact) *\/\n    .bd-post .bp-stat-callout {\n      background: var(--card-fill);\n      border: 1px solid var(--card-border);\n      border-left: 4px solid var(--accent);\n      padding: var(--pad-compact);\n      display: flex;\n      align-items: center;\n      gap: 12px;\n    }\n    .bd-post .bp-stat-icon { flex: 0 0 auto; color: var(--accent-text); }\n    .bd-post .bp-stat-icon svg { display: block; }\n    .bd-post .bp-stat-numeral { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 28px; color: var(--heading); line-height: 1; }\n    .bd-post .bp-stat-label { font-size: 14px; color: var(--text-secondary); }\n\n    \/* BP-2: Material Selection Card (medium, standalone, standard) *\/\n    .bd-post .bp-material-card {\n      background: var(--card-fill);\n      border: 1px solid var(--card-border);\n      padding: var(--pad-standard);\n      display: flex;\n      flex-direction: column;\n      gap: 0;\n    }\n    .bd-post .bp-material-title {\n      display: flex;\n      align-items: center;\n      gap: 8px;\n      font-family: \"Roboto\", sans-serif;\n      font-weight: 600;\n      font-size: 15px;\n      color: var(--heading);\n      padding-bottom: 12px;\n      margin-bottom: 4px;\n    }\n    .bd-post .bp-material-title svg { color: var(--accent-text); flex: 0 0 auto; }\n    .bd-post .bp-material-row {\n      display: flex;\n      align-items: center;\n      gap: 10px;\n      padding: 10px 0;\n      border-bottom: 1px solid var(--card-border);\n    }\n    .bd-post .bp-material-row:last-child { border-bottom: none; padding-bottom: 0; }\n    .bd-post .bp-material-row-icon { flex: 0 0 auto; color: var(--accent-text); }\n    .bd-post .bp-material-row-icon svg { display: block; }\n    .bd-post .bp-material-row-name { font-family: \"Roboto\", sans-serif; font-weight: 600; font-size: 15px; color: var(--heading); min-width: 170px; }\n    .bd-post .bp-material-row-use { font-size: 13px; color: var(--text-secondary); }\n\n    \/* BP-3: Procurement Checklist Card (medium, standalone, standard) *\/\n    .bd-post .bp-checklist-card {\n      background: var(--card-fill);\n      border: 1px solid var(--card-border);\n      padding: var(--pad-standard);\n      display: flex;\n      flex-direction: column;\n      gap: 14px;\n    }\n    .bd-post .bp-checklist-title {\n      display: flex;\n      align-items: center;\n      gap: 8px;\n      font-family: \"Roboto\", sans-serif;\n      font-weight: 600;\n      font-size: 16px;\n      color: var(--heading);\n      padding-bottom: 2px;\n    }\n    .bd-post .bp-checklist-title svg { color: var(--accent-text); flex: 0 0 auto; }\n    .bd-post .bp-checklist-item {\n      display: flex;\n      align-items: flex-start;\n      gap: 10px;\n    }\n    .bd-post .bp-checklist-num {\n      flex: 0 0 auto;\n      width: 24px; height: 24px;\n      border-radius: 50%;\n      background: var(--accent);\n      color: var(--btn-white);\n      font-family: \"Roboto\", sans-serif;\n      font-weight: 700;\n      font-size: 13px;\n      line-height: 24px;\n      text-align: center;\n    }\n    .bd-post .bp-checklist-body { flex: 1; min-width: 0; }\n    .bd-post .bp-checklist-label { font-family: \"Roboto\", sans-serif; font-weight: 600; font-size: 14px; color: var(--heading); }\n    .bd-post .bp-checklist-detail { font-size: 13px; color: var(--text-secondary); margin-top: 2px; }\n\n    \/* BP-cta-end: End CTA Panel (high, section, standard) *\/\n    .bd-post .bp-cta-end {\n      margin: var(--gap-section) 0 0;\n      background: var(--inverse-bg);\n      padding: var(--pad-standard);\n      display: flex;\n      align-items: center;\n      gap: 24px;\n      justify-content: space-between;\n    }\n    .bd-post .bp-cta-end-left { display: flex; align-items: flex-start; gap: 14px; flex: 1; min-width: 0; }\n    .bd-post .bp-cta-end-icon { flex: 0 0 auto; color: var(--inverse-text-accent); }\n    .bd-post .bp-cta-end-icon svg { display: block; }\n    .bd-post .bp-cta-end-body { flex: 1; min-width: 0; }\n    .bd-post .bp-cta-end-title { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 22px; color: var(--inverse-text); line-height: 1.25; }\n    .bd-post .bp-cta-end-subtitle { font-size: 15px; color: var(--inverse-text-secondary); margin-top: 4px; }\n    .bd-post .bp-cta-end-btn {\n      flex: 0 0 auto;\n      display: inline-block;\n      background: var(--accent-hot);\n      color: var(--btn-ink);\n      font-family: \"Roboto\", sans-serif;\n      font-weight: 600;\n      font-size: 15px;\n      padding: 12px 28px;\n      border-radius: 4px;\n      text-decoration: none;\n      white-space: nowrap;\n    }\n    .bd-post .bp-cta-end-btn:hover { color: var(--btn-ink); background: var(--accent-hot); }\n\n    \/* Motion *\/\n    @media (prefers-reduced-motion: no-preference) {\n      @supports (animation-timeline: view()) {\n        .bd-post .bd-reveal { animation: bd-fade-in linear both; animation-timeline: view(); animation-range: entry 0% entry 35%; }\n        @keyframes bd-fade-in { from { opacity: 0; } to { opacity: 1; } }\n      }\n      .bd-post h2 { transition: color .2s ease-out, transform .2s ease-out; transform-origin: left; }\n      .bd-post h2:hover { color: var(--text-accent); transform: scale(1.02); }\n      .bd-post .bp-material-card { transition: transform .2s ease-out, box-shadow .2s ease-out; }\n      .bd-post .bp-material-card:hover { transform: translateY(-2px); box-shadow: 0 6px 18px rgba(0,0,0,0.08); }\n      .bd-post .bp-checklist-card { transition: transform .2s ease-out, box-shadow .2s ease-out; }\n      .bd-post .bp-checklist-card:hover { transform: translateY(-2px); box-shadow: 0 6px 18px rgba(0,0,0,0.08); }\n      .bd-post .bp-cta-end-btn { transition: transform .2s ease-out, box-shadow .2s ease-out; }\n      .bd-post .bp-cta-end-btn:hover { transform: translateY(-1px); box-shadow: 0 4px 14px rgba(0,0,0,0.35); }\n      .bd-post .bp-material-row-icon { transition: color .2s ease-out; }\n      .bd-post .bp-material-row:hover .bp-material-row-icon { color: var(--accent-hot); }\n      .bd-post .bp-checklist-num { transition: transform .2s ease-out; }\n      .bd-post .bp-checklist-item:hover .bp-checklist-num { transform: scale(1.08); }\n      .bd-post .bd-post-article p a,\n      .bd-post .bd-post-article li a,\n      .bd-post .bd-post-article blockquote a,\n      .bd-post .bd-post-article td a { transition: color .15s ease-out; }\n      .bd-post .bd-post-article p a:hover,\n      .bd-post .bd-post-article li a:hover,\n      .bd-post .bd-post-article blockquote a:hover,\n      .bd-post .bd-post-article td a:hover { color: var(--accent-hot); }\n    }\n\n    \/* Mobile *\/\n    @media (max-width: 768px) {\n      .bd-post { padding: 16px; }\n      .bd-post h2 { font-size: 26px; margin-top: 32px; }\n      .bd-post h3 { font-size: 20px; margin-top: 24px; }\n      .bd-post .bp-stat-numeral { font-size: 24px; }\n      .bd-post .bp-material-row { flex-wrap: wrap; }\n      .bd-post .bp-material-row-name { min-width: 0; flex: 1; }\n      .bd-post .bp-cta-end { flex-direction: column; align-items: stretch; gap: 16px; }\n      .bd-post .bp-cta-end-btn { text-align: center; }\n      .bd-post .bp-cta-end-title { font-size: 20px; }\n    }\n  <\/style>\n\n  <article class=\"bd-post-article\">\n\n    <h1><\/h1>\n\n    <h2>DIN Ray\u0131 Nedir? Standard\u0131 Anlamak<\/h2>\n\n    <p>\u0130ster panel \u00fcreticileri i\u00e7in elektrik bile\u015fenleri stokluyor olun, ister kendi projeleriniz i\u00e7in par\u00e7alar belirliyor olun, s\u00fcrekli olarak tek bir donan\u0131m par\u00e7as\u0131yla u\u011fra\u015f\u0131rs\u0131n\u0131z: terminal bloklar\u0131n\u0131n, devre kesicilerin, r\u00f6lelerin ve g\u00fc\u00e7 kaynaklar\u0131n\u0131n hepsinin d\u00fczg\u00fcn s\u0131ralar halinde tak\u0131ld\u0131\u011f\u0131, arka plaka boyunca uzanan metal ray. Bu ray, bir DIN ray\u0131d\u0131r. Ve boyutlar\u0131 rastgele belirlenmi\u015f de\u011fildir \u2014 bu boyutlar\u0131 do\u011fru belirlemek, hizmet verdi\u011finiz her m\u00fc\u015fteri i\u00e7in \u00f6nemlidir.<\/p>\n\n    <p>DIN ray\u0131, 1928 y\u0131l\u0131na kadar uzan\u0131r; o d\u00f6nemde Alman elektrik \u015firketi RWE, ekipman muhafazalar\u0131n\u0131n i\u00e7ine bile\u015fenleri monte etmek i\u00e7in standartla\u015ft\u0131r\u0131lm\u0131\u015f bir y\u00f6nteme ihtiya\u00e7 duymu\u015ftu. Bu konsept daha sonra Phoenix Contact taraf\u0131ndan ticarile\u015ftirildi ve orijinal Alman DIN 46277-3 standard\u0131ndan ba\u015flayarak, Avrupa EN 50022 standard\u0131 \u00fczerinden g\u00fcn\u00fcm\u00fcz\u00fcn uluslararas\u0131 standartlar\u0131na kadar geli\u015fen bir dizi standartta kodland\u0131. <strong>Uluslararas\u0131 Elektroteknik Komisyonu 60715<\/strong> (g\u00fcncel bask\u0131: 2017, S\u00fcr\u00fcm 2.0). Almanya\u2019da buna kar\u015f\u0131l\u0131k gelen ulusal standart DIN EN 60715 \/ VDE 0660-520:2018-07\u2019dir.<\/p>\n\n    <p>\u201cDIN ray\u0131\u201d, tek bir boyutu ifade etmez. IEC 60715 standard\u0131, her biri milimetre cinsinden geni\u015flik ve y\u00fckseklik olmak \u00fczere iki say\u0131 ile tan\u0131mlanan d\u00f6rt standart profil belirler. 35 mm geni\u015fli\u011findeki TS35 serisi, k\u00fcresel kurulumlar\u0131n %\u2019sinden fazlas\u0131n\u0131 olu\u015fturur. Ancak TS35 serisi i\u00e7inde bile, iki farkl\u0131 derinlik varyant\u0131 \u00e7ok farkl\u0131 ama\u00e7lara hizmet eder.<\/p>\n\n    <p>DIN ray\u0131n\u0131 bir LEGO taban plakas\u0131 gibi d\u00fc\u015f\u00fcn\u00fcn: farkl\u0131 \u00fcreticilere ait bile\u015fenlerin \u2014 bir Schneider MCB, bir Weidm\u00fcller terminal blo\u011fu, bir Siemens PLC mod\u00fcl\u00fc \u2014 hepsinin ayn\u0131 montaj sistemine tak\u0131lmas\u0131n\u0131 sa\u011flayan evrensel bir mekanik aray\u00fczd\u00fcr.<\/p>\n\n    <!-- BP-1: Key Stat Callout -->\n    <div class=\"bp-stat-callout bd-reveal\">\n      <span class=\"bp-stat-icon\"><svg width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M3 3v18h18\"\/><path d=\"M7 16l4-8 4 4 4-6\"\/><\/svg><\/span>\n      <span class=\"bp-stat-numeral\">90%<\/span>\n      <span class=\"bp-stat-label\">D\u00fcnya \u00e7ap\u0131ndaki DIN ray\u0131 kurulumlar\u0131n\u0131n %'si TS35 \u00d7 7,5 kullanmaktad\u0131r<\/span>\n    <\/div>\n\n    <h2>T\u00fcre G\u00f6re Standart DIN Ray\u0131 Boyutlar\u0131<\/h2>\n\n    <p>IEC 60715 standard\u0131, her biri kendine \u00f6zg\u00fc bir geni\u015flik \u00d7 y\u00fckseklik kombinasyonuyla tan\u0131mlanan d\u00f6rt standart DIN ray\u0131 profilini tan\u0131mlamaktad\u0131r. TS35 serisi, modern kurulumlarda yayg\u0131n olarak kullan\u0131lmaktad\u0131r; TS15 ve TS32 serileri ise belirli ni\u015f uygulamalara y\u00f6neliktir. A\u015fa\u011f\u0131da, her bir tipin kesin boyutlar\u0131, toleranslar\u0131 ve tipik kullan\u0131m \u00f6rnekleri ayr\u0131nt\u0131l\u0131 olarak a\u00e7\u0131klanmaktad\u0131r.<\/p>\n\n    <h3>TS35 \u00d7 7,5 \u2014 K\u00fcresel Standart \u015eapka Ray\u0131<\/h3>\n\n    <p>Bir m\u00fchendis, herhangi bir a\u00e7\u0131klama yapmadan \u201cDIN ray\u0131\u201d dedi\u011finde, TS35 \u00d7 7,5\u2019i kasteder. Bu, evrensel standartt\u0131r. D\u00fcnya \u00e7ap\u0131nda hemen hemen her kontrol paneli, da\u011f\u0131t\u0131m panosu ve otomasyon kabininde bu ray\u0131 g\u00f6rebilirsiniz.<\/p>\n\n    <p><strong>Kesin boyutlar:<\/strong><\/p>\n    <ul>\n      <li>Geni\u015flik: 35 mm (IEC 60715 standard\u0131na g\u00f6re \u00b10,3 mm tolerans)<\/li>\n      <li>Y\u00fckseklik: 7,5 mm (+0 \/ \u22120,4 mm tolerans)<\/li>\n      <li>Malzeme kal\u0131nl\u0131\u011f\u0131: 1,0 mm (so\u011fuk haddelenmi\u015f \u00e7elik DC01, EN 10130 standard\u0131na g\u00f6re)<\/li>\n      <li>A\u011f\u0131rl\u0131k: metre ba\u015f\u0131na yakla\u015f\u0131k 0,30\u20130,35 kg (\u00e7inko kapl\u0131 \u00e7elik)<\/li>\n    <\/ul>\n\n    <p><strong>Tipik kullan\u0131m alanlar\u0131:<\/strong><\/p>\n    <ul>\n      <li>Minyat\u00fcr devre kesiciler (MCB\u2019ler): 18 mm geni\u015fli\u011findeki standart tek kutuplu bir MCB, TS35\u2019e do\u011frudan tak\u0131l\u0131r<\/li>\n      <li>Terminal bloklar\u0131: Vidal\u0131 ve yayl\u0131 klemplere sahip terminallerin b\u00fcy\u00fck \u00e7o\u011funlu\u011fu TS35 ile uyumludur<\/li>\n      <li>PLC G\/\u00c7 mod\u00fclleri, sinyal d\u00fczenleyiciler ve k\u00fc\u00e7\u00fck r\u00f6leler<\/li>\n    <\/ul>\n\n    <p>Delikli TS35 raylar\u0131n\u0131n \u00e7o\u011funda, merkezler aras\u0131 mesafesi 25 mm olan 6,2 mm \u00d7 15 mm boyutlar\u0131nda dikd\u00f6rtgen montaj yuvalar\u0131 bulunur. Bu delik d\u00fczeni, sekt\u00f6rde fiilen kabul g\u00f6rm\u00fc\u015f bir standartt\u0131r. IEC 60715 standard\u0131 bunu a\u00e7\u0131k\u00e7a zorunlu k\u0131lmamaktad\u0131r, ancak neredeyse t\u00fcm \u00fcreticiler bu standarda uymaktad\u0131r. Standart tedarik uzunluklar\u0131 1 metre ve 2 metredir; ayr\u0131ca \u00e7o\u011fu tedarik\u00e7iden \u00f6zel kesim se\u00e7enekleri de temin edilebilir.<\/p>\n\n    <p>H\u0131zl\u0131 ba\u015fvuru i\u00e7in: Bir metrelik TS35 \u00d7 7,5, yakla\u015f\u0131k 10\u201312 adet standart tek kutuplu MCB\u2019ye (her biri 18 mm) veya yakla\u015f\u0131k 150\u2013200 adet kompakt terminal blo\u011funa (her biri 5\u20136 mm) yer sa\u011flar.<\/p>\n\n    <h3>TS35 \u00d7 15 \u2014 A\u011f\u0131r Hizmet Uygulamalar\u0131 i\u00e7in Derin Silindir Ba\u015fl\u0131kl\u0131 Vida<\/h3>\n\n    <p>Ayn\u0131 35 mm geni\u015flik, iki kat\u0131 derinlik \u2014 ve sertlik a\u00e7\u0131s\u0131ndan iki kat\u0131ndan da \u00f6nemli \u00f6l\u00e7\u00fcde fazla.<\/p>\n\n    <p><strong>Kesin boyutlar:<\/strong><\/p>\n    <ul>\n      <li>Geni\u015flik: 35 mm<\/li>\n      <li>Y\u00fckseklik: 15 mm<\/li>\n      <li>Malzeme kal\u0131nl\u0131\u011f\u0131: 1,5 mm (baz\u0131 \u00fcreticiler 2,0\u20132,3 mm kal\u0131nl\u0131\u011f\u0131nda takviyeli versiyonlar sunmaktad\u0131r)<\/li>\n      <li>A\u011f\u0131rl\u0131k: metre ba\u015f\u0131na yakla\u015f\u0131k 0,62\u20130,65 kg<\/li>\n    <\/ul>\n\n    <p>Aradaki temel fark yap\u0131sald\u0131r. 15 mm derinli\u011findeki profil, 7,5 mm\u2019lik versiyonun kesit mod\u00fcl\u00fcn\u00fcn yakla\u015f\u0131k 3\u20134 kat\u0131na sahiptir; bu sayede a\u011f\u0131r y\u00fckler alt\u0131nda e\u011filmeye kar\u015f\u0131 \u00e7ok daha iyi diren\u00e7 g\u00f6sterir. Titre\u015fime maruz kalan ortamlarda \u2014 fabrika zeminlerindeki makine kontrol dolaplar\u0131, hareketli ekipmanlar\u0131n i\u00e7indeki paneller \u2014 TS35 \u00d7 15 standart tercihtir.<\/p>\n\n    <p><strong>TS35 \u00d7 7,5 yerine TS35 \u00d7 15 ne zaman kullan\u0131lmal\u0131d\u0131r:<\/strong><\/p>\n    <ul>\n      <li>A\u011f\u0131r g\u00fc\u00e7 kaynaklar\u0131n\u0131n (200 W ve \u00fczeri) montaj\u0131<\/li>\n      <li>B\u00fcy\u00fck kontakt\u00f6rler ve motor devreye al\u0131c\u0131lar\u0131<\/li>\n      <li>Tek ba\u015f\u0131na a\u011f\u0131rl\u0131\u011f\u0131 2\u20133 kg\u2019dan fazla olan herhangi bir bile\u015fen<\/li>\n      <li>S\u00fcrekli mekanik titre\u015fimin oldu\u011fu ortamlar<\/li>\n      <li>Montaj vidalar\u0131n\u0131n aral\u0131\u011f\u0131 400 mm\u2019yi a\u015ft\u0131\u011f\u0131nda: daha derin profil, sarkma olmadan daha uzun a\u00e7\u0131kl\u0131klar\u0131 k\u00f6pr\u00fcler<\/li>\n    <\/ul>\n\n    <p>Pratik bir kural: Bir elinizle kald\u0131rd\u0131\u011f\u0131n\u0131zda par\u00e7an\u0131n a\u011f\u0131rl\u0131\u011f\u0131n\u0131 hissediyorsan\u0131z, onu TS35 \u00d7 15 \u00fczerine monte edin.<\/p>\n\n    <h3>TS15 \u2014 Dar Alanlar \u0130\u00e7in Minyat\u00fcr Ray<\/h3>\n\n    <p>TS15, k\u00fc\u00e7\u00fclt\u00fclm\u00fc\u015f versiyonudur. Ayn\u0131 \u015fapka geometrisine sahiptir, ancak 15 mm geni\u015fli\u011finde ve sadece 5,5 mm y\u00fcksekli\u011findedir.<\/p>\n\n    <p><strong>Kesin boyutlar:<\/strong><\/p>\n    <ul>\n      <li>Geni\u015flik: 15 mm (\u00b10,15 mm \u2014 TS35'ten daha s\u0131k\u0131 tolerans)<\/li>\n      <li>Y\u00fckseklik: 5,5 mm (\u00b10,1 mm)<\/li>\n      <li>Malzeme kal\u0131nl\u0131\u011f\u0131: 1,0 mm<\/li>\n      <li>A\u011f\u0131rl\u0131k: metre ba\u015f\u0131na yakla\u015f\u0131k 0,14 kg<\/li>\n      <li>Uygulanacak standart: EN 50045 (EN 50022 de\u011fil)<\/li>\n    <\/ul>\n\n    <p>TS15, tam boy 35 mm'lik bir ray\u0131n de\u011ferli muhafaza alan\u0131n\u0131 bo\u015fa harcayaca\u011f\u0131 durumlarda kompakt ba\u011flant\u0131 kutular\u0131, bina otomasyon kontrol\u00f6rleri ve minyat\u00fcr r\u00f6le mod\u00fclleri i\u00e7in kullan\u0131l\u0131r. Ayr\u0131ca, HVAC kontrol panellerinde ve ayd\u0131nlatma kontrol sistemlerinde de yayg\u0131n olarak kullan\u0131l\u0131r.<\/p>\n\n    <p><strong>\u00d6nemli uyumluluk notu:<\/strong> TS15'e monte edilen bile\u015fenler, TS35 ray\u0131na do\u011frudan tak\u0131lamaz. Ayn\u0131 panelde TS15 ve TS35 cihazlar\u0131n\u0131 bir arada kullanman\u0131z gerekiyorsa, adapt\u00f6r braketlerine veya ayr\u0131 ray b\u00f6l\u00fcmlerine ihtiyac\u0131n\u0131z olacakt\u0131r.<\/p>\n\n    <h3>TS32 (G-Kesiti) \u2014 Legacy A\u011f\u0131r Hizmet Demiryolu<\/h3>\n\n    <p>TS32, IEC \u00f6ncesi d\u00f6neme dayanan ve halen aktif olarak kullan\u0131lan en eski profildir. Simetrik \u015fapka \u015feklinden farkl\u0131 olarak, TS32 asimetrik G \u015feklinde bir kesite sahiptir.<\/p>\n\n    <p><strong>Kesin boyutlar:<\/strong><\/p>\n    <ul>\n      <li>Geni\u015flik: 32 mm<\/li>\n      <li>Y\u00fckseklik: 15 mm<\/li>\n      <li>Malzeme kal\u0131nl\u0131\u011f\u0131: 1,5 mm<\/li>\n      <li>\u0130lgili standart: EN 50035<\/li>\n    <\/ul>\n\n    <p>Asimetrik G profili, beklenmedik bir avantaj sa\u011flar: Bile\u015fenler yaln\u0131zca tek bir y\u00f6nden tak\u0131labilir, bu da do\u011fal bir polarite korumas\u0131 olu\u015fturur. Bir cihaz\u0131 ters olarak takmak fiziksel olarak imk\u00e2ns\u0131zd\u0131r. Bu \u00f6zellik, TS32\u2019yi eski Avrupa tesisatlar\u0131ndaki a\u011f\u0131r hizmet kontakt\u00f6rleri, b\u00fcy\u00fck transformat\u00f6rler ve motor \u00e7al\u0131\u015ft\u0131r\u0131c\u0131lar\u0131 i\u00e7in pop\u00fcler hale getirmi\u015ftir.<\/p>\n\n    <p>G\u00fcn\u00fcm\u00fczde TS32 uygulamalar\u0131n\u0131n \u00e7o\u011fu TS35 \u00d7 15 standard\u0131na ge\u00e7mi\u015ftir. Bununla birlikte, \u00f6zellikle Almanya, Avusturya ve Do\u011fu Avrupa\u2019da eski ekipmanlar\u0131n yenilenmesi \u00e7al\u0131\u015fmalar\u0131nda TS32 h\u00e2l\u00e2 kullan\u0131lmaktad\u0131r. Ayr\u0131ca, esas olarak Avustralya standard\u0131 AS 2756-1997\u2019nin ge\u00e7erli oldu\u011fu pazarlarda, C kesitli bir varyant (C20, C30, C40, C50 \u2014 y\u00fcksekli\u011fe g\u00f6re mm cinsinden adland\u0131r\u0131l\u0131r) da mevcuttur.<\/p>\n\n    <p>Yeni tasar\u0131mlarda, TS32\u2019nin yerine neredeyse her durumda TS35 \u00d7 15\u2019in kullan\u0131lmas\u0131 \u00f6nerilir.<\/p>\n\n    <h2>DIN Ray\u0131 Boyut Kar\u015f\u0131la\u015ft\u0131rmas\u0131 Bir Bak\u0131\u015fta<\/h2>\n<img decoding=\"async\" src=\"https:\/\/www.omch.com\/wp-content\/uploads\/2026\/07\/Gemini_Generated_Image_p0ish3p0ish3p0is.webp\" alt=\"A\u00e7\u0131klama metni\" class=\"bd-post-image\" loading=\"lazy\">\n\n    <p>DIN ray\u0131 boyutlar\u0131n\u0131 do\u011frulamak i\u00e7in tek bir kaynak ar\u0131yorsan\u0131z, i\u015fte bu kaynak tam da arad\u0131\u011f\u0131n\u0131z \u015fey.<\/p>\n\n    <div class=\"table-wrapper\">\n    <table>\n      <thead><tr><th>Tip<\/th><th>Geni\u015flik<\/th><th>Y\u00fckseklik<\/th><th>Kal\u0131nl\u0131k<\/th><th>A\u011f\u0131rl\u0131k (kg\/m)<\/th><th>\u0130\u00e7in En \u0130yisi<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td><strong>\u00dc\u00e7 bu\u00e7uk be\u015f<\/strong><\/td><td>35 mm<\/td><td>7,5 mm<\/td><td>1,0 mm<\/td><td>0,30\u20130,35<\/td><td>MCB\u2019ler, terminaller, r\u00f6leler, PLC\u2019ler<\/td><\/tr>\n        <tr><td><strong>\u00dc\u00e7 adet be\u015f \u00e7arp\u0131 on be\u015f<\/strong><\/td><td>35 mm<\/td><td>15 mm<\/td><td>1,5 mm<\/td><td>0,62\u20130,65<\/td><td>G\u00fc\u00e7 kaynaklar\u0131, kontakt\u00f6rler, a\u011f\u0131r y\u00fckler<\/td><\/tr>\n        <tr><td><strong>TS15<\/strong><\/td><td>15 mm<\/td><td>5,5 mm<\/td><td>1,0 mm<\/td><td>0.14<\/td><td>Kompakt kutular, minyat\u00fcr r\u00f6leler<\/td><\/tr>\n        <tr><td><strong>\u00dc\u00e7 y\u0131ld\u0131z (Alt\u0131n)<\/strong><\/td><td>32 mm<\/td><td>15 mm<\/td><td>1,5 mm<\/td><td>~0.58<\/td><td>Eski tip kontakt\u00f6rler, transformat\u00f6rler<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <\/div>\n\n    <p><strong>\u0130n\u00e7 cinsinden kar\u015f\u0131l\u0131klar\u0131<\/strong> (\u0130mperyal birimlerin belirtildi\u011fi pazarlar i\u00e7in):<\/p>\n    <ul>\n      <li>35 mm = 1,378\u2033<\/li>\n      <li>15 mm = 0,591\u2033<\/li>\n      <li>7,5 mm = 0,295 in\u00e7<\/li>\n      <li>5,5 mm = 0,217\u2033<\/li>\n      <li>32 mm = 1,260\u2033<\/li>\n    <\/ul>\n\n    <p><strong>Standart montaj deli\u011fi d\u00fczeni<\/strong> (delikli ray): 25 mm merkezler aras\u0131 aral\u0131kta 6,2 mm \u00d7 15 mm boyutlar\u0131nda dikd\u00f6rtgen yuvalar.<\/p>\n\n    <p><strong>Standart tedarik uzunluklar\u0131:<\/strong> 1 metre ve 2 metre. \u00c7o\u011fu \u00fcretici ve distrib\u00fct\u00f6rden \u00f6zel uzunluklarda temin edilebilir.<\/p>\n\n    <p><em>Not: IEC 60715 standard\u0131nda TH 75-25 profili (75 mm geni\u015flik \u00d7 25 mm y\u00fckseklik) de tan\u0131mlanmaktad\u0131r; ancak bu varyant\u0131n ticari kullan\u0131m alan\u0131 neredeyse hi\u00e7 yoktur ve yukar\u0131daki kar\u015f\u0131la\u015ft\u0131rmaya dahil edilmemi\u015ftir.<\/em><\/p>\n\n    <p>Bu tabloyu kaydedin veya ekran g\u00f6r\u00fcnt\u00fcs\u00fcn\u00fc al\u0131n. Bu tablo, sahada kar\u015f\u0131la\u015fabilece\u011finiz t\u00fcm standart DIN ray\u0131 boyutlar\u0131n\u0131 kapsamaktad\u0131r.<\/p>\n\n    <h2>Do\u011fru DIN Ray\u0131 Boyutu Nas\u0131l Se\u00e7ilir?<\/h2>\n\n    <p>Boyutlar\u0131 bilmek ilk ad\u0131md\u0131r. M\u00fc\u015fterilerinizin uygulamalar\u0131na en uygun profili se\u00e7melerine yard\u0131mc\u0131 olmak ikinci ad\u0131md\u0131r \u2014 ve bu bilgi sayesinde ger\u00e7ekten sat\u0131lan boyutlar\u0131 stokta bulundurabilirsiniz. Karar\u0131 etkileyen \u00fc\u00e7 fakt\u00f6r vard\u0131r: neyin monte edilece\u011fi, panelin yerle\u015ftirilece\u011fi yer ve hedef pazar\u0131n hangi standartlar\u0131 gerektirdi\u011fi.<\/p>\n\n    <h3>Y\u00fck A\u011f\u0131rl\u0131\u011f\u0131na ve Uygulama T\u00fcr\u00fcne G\u00f6re<\/h3>\n\n    <p>DIN ray\u0131 se\u00e7iminde yap\u0131lan en yayg\u0131n hata \u2014 ister m\u00fc\u015fteriniz paneli monte ediyor olsun, ister siz yeniden sat\u0131\u015f i\u00e7in stok olu\u015fturuyor olun \u2014 monte edilecek bile\u015fenlerin toplam a\u011f\u0131rl\u0131\u011f\u0131n\u0131 hafife almakt\u0131r.<\/p>\n\n    <p><strong>H\u0131zl\u0131 se\u00e7im k\u0131lavuzu:<\/strong><\/p>\n\n    <div class=\"table-wrapper\">\n    <table>\n      <thead><tr><th>Uygulama<\/th><th>\u00d6nerilen Ray<\/th><th>Notlar<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>Hafif y\u00fck: terminal bloklar\u0131, k\u00fc\u00e7\u00fck r\u00f6leler, sinyal d\u00fczenleyiciler<\/td><td>\u00dc\u00e7 bu\u00e7uk be\u015f<\/td><td>Her 400\u2013500 mm'de bir montaj vidalar\u0131 kullan\u0131labilir<\/td><\/tr>\n        <tr><td>Orta y\u00fck: MCB\u2019ler, kompakt PLC\u2019ler, k\u00fc\u00e7\u00fck g\u00fc\u00e7 kaynaklar\u0131 (\u2264120 W)<\/td><td>\u00dc\u00e7 bu\u00e7uk be\u015f<\/td><td>Vida aral\u0131\u011f\u0131n\u0131 250\u2013300 mm\u2019ye indirin<\/td><\/tr>\n        <tr><td>A\u011f\u0131r y\u00fck: b\u00fcy\u00fck g\u00fc\u00e7 kaynaklar\u0131 (200 W ve \u00fczeri), kontakt\u00f6rler, frekans d\u00f6n\u00fc\u015ft\u00fcr\u00fcc\u00fcler<\/td><td>\u00dc\u00e7 adet be\u015f \u00e7arp\u0131 on be\u015f<\/td><td>Vida aral\u0131\u011f\u0131 \u2264 200 mm; u\u00e7 kelep\u00e7eleri ekleyin<\/td><\/tr>\n        <tr><td>A\u015f\u0131r\u0131 y\u00fck\/titre\u015fim: transformat\u00f6r panelleri, denizcilik\/mobil ekipmanlar<\/td><td>TS35 \u00d7 15 (g\u00fc\u00e7lendirilmi\u015f)<\/td><td>Tutma kuvveti \u2265 50 N olan u\u00e7 durdurucular<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <\/div>\n\n    <p>Pratik bir referans olarak: 300 mm aral\u0131kl\u0131 destekler \u00fczerinde kullan\u0131lan TS35 \u00d7 7,5, statik ko\u015fullarda metre ba\u015f\u0131na yakla\u015f\u0131k 8\u201315 kg\u2019l\u0131k e\u015fit da\u011f\u0131lm\u0131\u015f y\u00fck\u00fc ta\u015f\u0131yabilir. Titre\u015fimli ortamlarda, y\u00fck kapasitesi 50% oran\u0131nda azalt\u0131lmal\u0131d\u0131r. Ayn\u0131 a\u00e7\u0131kl\u0131kta TS35 \u00d7 15 kullan\u0131ld\u0131\u011f\u0131nda g\u00fcvenli y\u00fck \u00fc\u00e7 kat\u0131na \u00e7\u0131kar.<\/p>\n\n    <p>A\u011f\u0131r kurulumlarda u\u00e7 durdurucular (u\u00e7 kelep\u00e7eleri) zorunludur. Standart bir u\u00e7 kelep\u00e7esi, en az 20 N\u2019luk yanal tutma kuvveti sa\u011flayarak, titre\u015fim alt\u0131nda bile\u015fenlerin ray boyunca kaymas\u0131n\u0131 \u00f6nler.<\/p>\n\n    <h3>Malzeme ve Ortam Ko\u015fullar\u0131na G\u00f6re<\/h3>\n\n    <p>Yanl\u0131\u015f malzemeden yap\u0131lm\u0131\u015f do\u011fru beden, yanl\u0131\u015f beden kadar kesin bir \u015fekilde ba\u015far\u0131s\u0131z olur.<\/p>\n\n    <div class=\"table-wrapper\">\n    <table>\n      <thead><tr><th>Malzeme<\/th><th>Korozyon Direnci<\/th><th>G\u00f6receli Maliyet<\/th><th>En \u0130yi \u00c7evre<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td><strong>\u00c7inko kapl\u0131 \u00e7elik<\/strong> (DC01)<\/td><td>Orta d\u00fczeyde<\/td><td>Ba\u015flang\u0131\u00e7 de\u011feri (1\u00d7)<\/td><td>Standart i\u00e7 mekan panelleri, iklim kontroll\u00fc odalar<\/td><\/tr>\n        <tr><td><strong>Al\u00fcminyum<\/strong><\/td><td>\u0130yi<\/td><td>~1,5\u00d7<\/td><td>Hafif uygulamalar, orta d\u00fczeyde nem<\/td><\/tr>\n        <tr><td><strong>304 paslanmaz \u00e7elik<\/strong><\/td><td>\u00c7ok iyi<\/td><td>~2,5\u20133 kat<\/td><td>G\u0131da i\u015fleme, ila\u00e7 sekt\u00f6r\u00fc, d\u0131\u015f mekan dolaplar\u0131<\/td><\/tr>\n        <tr><td><strong>316 paslanmaz \u00e7elik<\/strong><\/td><td>M\u00fckemmel<\/td><td>~3\u20134 kat<\/td><td>Denizcilik, kimya tesisleri, y\u00fcksek klor\u00fcr i\u00e7eren ortamlar<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <\/div>\n\n    <p>304 ve 316 paslanmaz \u00e7elik aras\u0131ndaki en \u00f6nemli fark \u015fudur: 316, 2\u20133% molibden i\u00e7erir ve bu da 304\u2019e k\u0131yasla klor\u00fcr \u00e7ukurla\u015fmas\u0131na kar\u015f\u0131 yakla\u015f\u0131k 3\u20135 kat daha fazla diren\u00e7 sa\u011flar. Panelin\u00fcz bir k\u0131y\u0131 \u015feridinden 5 km mesafe i\u00e7indeyse veya kimyasal temizlik maddelerinin kullan\u0131ld\u0131\u011f\u0131 herhangi bir tesiste bulunuyorsa, 316 daha g\u00fcvenli bir se\u00e7imdir.<\/p>\n\n    <p>\u00c7inko kaplamal\u0131 \u00e7elik, i\u00e7 mekan end\u00fcstriyel uygulamalar\u0131n b\u00fcy\u00fck \u00e7o\u011funlu\u011fu i\u00e7in h\u00e2l\u00e2 standart se\u00e7enek olmaya devam etmektedir. Standart \u00e7inko kaplama kal\u0131nl\u0131\u011f\u0131 en az 6 mikrondur (DIN 50960 standard\u0131na g\u00f6re, kaplama s\u0131n\u0131f\u0131 gal Zn 8c).<\/p>\n\n    <!-- BP-2: Material Selection Card -->\n    <div class=\"bp-material-card bd-reveal\">\n      <div class=\"bp-material-title\">\n        <svg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><circle cx=\"12\" cy=\"12\" r=\"3\"\/><path d=\"M19.4 15a1.65 1.65 0 0 0 .33 1.82l.06.06a2 2 0 0 1-2.83 2.83l-.06-.06a1.65 1.65 0 0 0-1.82-.33 1.65 1.65 0 0 0-1 1.51V21a2 2 0 0 1-4 0v-.09A1.65 1.65 0 0 0 9 19.4a1.65 1.65 0 0 0-1.82.33l-.06.06a2 2 0 0 1-2.83-2.83l.06-.06A1.65 1.65 0 0 0 4.68 15a1.65 1.65 0 0 0-1.51-1H3a2 2 0 0 1 0-4h.09A1.65 1.65 0 0 0 4.6 9a1.65 1.65 0 0 0-.33-1.82l-.06-.06a2 2 0 0 1 2.83-2.83l.06.06A1.65 1.65 0 0 0 9 4.68a1.65 1.65 0 0 0 1-1.51V3a2 2 0 0 1 4 0v.09a1.65 1.65 0 0 0 1 1.51 1.65 1.65 0 0 0 1.82-.33l.06-.06a2 2 0 0 1 2.83 2.83l-.06.06A1.65 1.65 0 0 0 19.4 9a1.65 1.65 0 0 0 1.51 1H21a2 2 0 0 1 0 4h-.09a1.65 1.65 0 0 0-1.51 1z\"\/><\/svg>\n        Malzeme Se\u00e7imi: Genel Bak\u0131\u015f\n      <\/div>\n      <div class=\"bp-material-row\">\n        <span class=\"bp-material-row-icon\"><svg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\/><path d=\"m9 12 2 2 4-4\"\/><\/svg><\/span>\n        <span class=\"bp-material-row-name\">\u00c7inko kapl\u0131 \u00e7elik<\/span>\n        <span class=\"bp-material-row-use\">Standart i\u00e7 mekan panelleri<\/span>\n      <\/div>\n      <div class=\"bp-material-row\">\n        <span class=\"bp-material-row-icon\"><svg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\/><path d=\"m9 12 2 2 4-4\"\/><\/svg><\/span>\n        <span class=\"bp-material-row-name\">304 paslanmaz \u00e7elik<\/span>\n        <span class=\"bp-material-row-use\">G\u0131da, ila\u00e7, d\u0131\u015f mekan dolaplar\u0131<\/span>\n      <\/div>\n      <div class=\"bp-material-row\">\n        <span class=\"bp-material-row-icon\"><svg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\/><path d=\"m9 12 2 2 4-4\"\/><\/svg><\/span>\n        <span class=\"bp-material-row-name\">316 paslanmaz \u00e7elik<\/span>\n        <span class=\"bp-material-row-use\">Denizcilik, kimya tesisleri<\/span>\n      <\/div>\n      <div class=\"bp-material-row\">\n        <span class=\"bp-material-row-icon\"><svg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\/><path d=\"m9 12 2 2 4-4\"\/><\/svg><\/span>\n        <span class=\"bp-material-row-name\">Al\u00fcminyum<\/span>\n        <span class=\"bp-material-row-use\">Hafif, orta d\u00fczeyde nem<\/span>\n      <\/div>\n    <\/div>\n\n    <h3>Uyum Standartlar\u0131 ve B\u00f6lgesel Gerekliliklere G\u00f6re<\/h3>\n\n    <p>Bu, \u00e7o\u011fu k\u0131lavuzun atlad\u0131\u011f\u0131 bir husustur. Ayn\u0131 zamanda ihracat projelerinde en pahal\u0131 s\u00fcrprizlere yol a\u00e7an husustur.<\/p>\n\n    <p>DIN ray\u0131 kendili\u011finden bir CE i\u015fareti ta\u015f\u0131maz. Bu bir bile\u015fendir, bitmi\u015f bir cihaz de\u011fildir. Ancak standartlara uygun olmayan bir ray kullan\u0131lmas\u0131, panel montaj\u0131n\u0131z\u0131n tamam\u0131n\u0131n hedef pazarda sertifikasyon s\u00fcrecinden ge\u00e7ememesine neden olabilir.<\/p>\n\n    <p><strong>Pazar baz\u0131nda standartlara ili\u015fkin referans:<\/strong><\/p>\n\n    <div class=\"table-wrapper\">\n    <table>\n      <thead><tr><th>Pazar<\/th><th>Uygulanacak Standart<\/th><th>Temel Fark<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>Avrupa Birli\u011fi<\/td><td>IEC\/EN 60715<\/td><td>Varsay\u0131lan k\u00fcresel standart<\/td><\/tr>\n        <tr><td>Kuzey Amerika<\/td><td>UL 60715<\/td><td>Teknik a\u00e7\u0131dan IEC 60715 standard\u0131yla ayn\u0131d\u0131r, ancak UL onay\u0131 ayr\u0131 bir sertifikasyondur. Ray tedarik\u00e7inizin UL onay\u0131 ald\u0131\u011f\u0131n\u0131 kontrol edin.<\/td><\/tr>\n        <tr><td>Birle\u015fik Krall\u0131k<\/td><td>BS 5584<\/td><td>Eski \u0130ngiliz standard\u0131; yeni tasar\u0131mlar i\u00e7in IEC 60715 kabul edilmi\u015ftir<\/td><\/tr>\n        <tr><td>Avustralya \/ Yeni Zelanda<\/td><td>AS 2756-1997<\/td><td>IEC 60715 standard\u0131n\u0131n kapsam\u0131na girmeyen C kesitli profiller (C20, C30) dahildir<\/td><\/tr>\n        <tr><td>Orta Do\u011fu \/ G\u00fcney Asya<\/td><td>IEC veya BS (projeye ba\u011fl\u0131 olarak)<\/td><td>Eski \u0130ngiliz kolonilerinde d\u00fczenlenen bir\u00e7ok ihale, h\u00e2l\u00e2 BS standartlar\u0131na at\u0131fta bulunmaktad\u0131r. \u015eartnamenin asl\u0131nda hangi standard\u0131 gerektirdi\u011fini do\u011frulay\u0131n.<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <\/div>\n\n    <p>\u0130hracat projeleri i\u00e7in pratik bir ipucu: Malzeme listesinde \u201cIEC 60715 uyumlu\u201d ifadesini belirtin. Bu, d\u00fcnya \u00e7ap\u0131nda en yayg\u0131n olarak kabul g\u00f6ren referanst\u0131r. Kuzey Amerika panelleri i\u00e7in, ray\u0131n UL Onayl\u0131 Bile\u015fen i\u015faretini ta\u015f\u0131d\u0131\u011f\u0131n\u0131 do\u011frulay\u0131n. Bu, IEC uyumlulu\u011fundan ayr\u0131 bir husustur ve UL 508A panel denetimleri s\u0131ras\u0131nda kontrol edilir.<\/p>\n\n    <h2>DIN Ray\u0131 Tedariki: Sat\u0131n Al\u0131rken Dikkat Edilmesi Gerekenler<\/h2>\n\n    <p>Boyut, malzeme ve uygunluk gerekliliklerini netle\u015ftirdikten sonra, tedarik a\u015famas\u0131 i\u00e7in de kendine \u00f6zg\u00fc bir kontrol listesi vard\u0131r. Bu be\u015f nokta, tedarik s\u00fcrecindeki en yayg\u0131n tuzaklardan ka\u00e7\u0131nman\u0131za yard\u0131mc\u0131 olacakt\u0131r.<\/p>\n\n    <p><strong>1. IEC 60715 standard\u0131na uygunluk belgelerini talep edin.<\/strong> Sayg\u0131n herhangi bir tedarik\u00e7i, talep \u00fczerine malzeme sertifikas\u0131 ve boyutsal uygunluk raporu sunmal\u0131d\u0131r. E\u011fer bunlar\u0131 sunamazlarsa, o tedarik\u00e7iden uzak durun. Flan\u015f kenar\u0131nda 0,5 mm kadar k\u00fc\u00e7\u00fck boyutsal sapmalar bile bile\u015fenlerin do\u011fru \u015fekilde oturmas\u0131n\u0131 engelleyebilir.<\/p>\n\n    <p><strong>2. Delme gerekliliklerini ba\u015ftan netle\u015ftirin.<\/strong> Delikli ray (\u00f6nceden delinmi\u015f montaj yuvalar\u0131 ile birlikte), \u00e7o\u011fu uygulama i\u00e7in varsay\u0131lan se\u00e7enektir. Deliksiz raya ihtiyac\u0131n\u0131z varsa \u2014 \u00f6rne\u011fin, \u00f6zel montaj delikleri a\u00e7may\u0131 planl\u0131yorsan\u0131z \u2014 sipari\u015f vermeden \u00f6nce bunu belirtin. Delik boyutlar\u0131n\u0131 (standart boyut 6,2 \u00d7 15 mm) ve merkezden merkeze mesafeyi (25 mm) teyit edin.<\/p>\n\n    <p><strong>3. Malzeme ve kaplama \u00f6zelliklerini kontrol edin.<\/strong> Malzeme tan\u0131m\u0131 olarak \u201c\u00e7elik\u201d ifadesini kabul etmeyin. Spesifik kaliteyi (EN 10130'a g\u00f6re DC01, so\u011fuk haddelenmi\u015f \u00e7elik i\u00e7in standartt\u0131r), \u00e7inko kaplama kal\u0131nl\u0131\u011f\u0131n\u0131 (en az 6 \u00b5m) ve pasivasyon i\u015flemini talep edin. Paslanmaz \u00e7elik sipari\u015flerinde, fabrika sertifikas\u0131nda kesin kalite belirtilmelidir: 304 i\u00e7in 1.4301, 316 i\u00e7in 1.4401\/1.4404.<\/p>\n\n    <p><strong>4. Tedarik uzunluklar\u0131n\u0131 ve minimum sipari\u015f miktarlar\u0131n\u0131 teyit edin.<\/strong> Standart uzunluklar 1 m ve 2 m\u2019dir. Tasar\u0131m\u0131n\u0131z standart d\u0131\u015f\u0131 uzunluklar gerektiriyorsa, kesim hizmetinin fiyata dahil olup olmad\u0131\u011f\u0131n\u0131 veya ayr\u0131 olarak \u00fccretlendirilip edilmedi\u011fini teyit edin. End\u00fcstriyel DIN raylar\u0131 i\u00e7in tipik minimum sipari\u015f miktarlar\u0131, tedarik\u00e7iye ve teknik \u00f6zelliklere ba\u011fl\u0131 olarak 100 ila 500 metre aras\u0131nda de\u011fi\u015fmektedir.<\/p>\n\n    <p><strong>5. Ambalaj\u0131 ve nakliye s\u0131ras\u0131nda sa\u011flanan korumay\u0131 kontrol edin.<\/strong> DIN ray\u0131 uzun ve incedir; nakliye s\u0131ras\u0131nda kolayca b\u00fck\u00fclebilir. Tedarik\u00e7inin sa\u011flam ambalaj kulland\u0131\u011f\u0131ndan emin olun \u2014 ideal olarak, 1 m\u2019den uzun raylar i\u00e7in ah\u015fap kasalar veya takviyeli karton borular kullan\u0131lmal\u0131d\u0131r. \u00c7\u0131plak g\u00f6zle bak\u0131ld\u0131\u011f\u0131nda sorunsuz g\u00f6r\u00fcnen b\u00fck\u00fclm\u00fc\u015f bir ray, bile\u015fenler tak\u0131ld\u0131ktan sonra montaj hatalar\u0131na neden olabilir.<\/p>\n\n    <!-- BP-3: Procurement Checklist Card -->\n    <div class=\"bp-checklist-card bd-reveal\">\n      <div class=\"bp-checklist-title\">\n        <svg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M11 18h2\"\/><path d=\"M11 14h4\"\/><path d=\"M11 10h4\"\/><path d=\"M7 6h1\"\/><path d=\"M5 2h14a2 2 0 0 1 2 2v16a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2V4a2 2 0 0 1 2-2z\"\/><\/svg>\n        Sipari\u015f Vermeden \u00d6nce\n      <\/div>\n      <div class=\"bp-checklist-item\">\n        <span class=\"bp-checklist-num\">1<\/span>\n        <div class=\"bp-checklist-body\">\n          <div class=\"bp-checklist-label\">IEC 60715 uyumluluk belgelerini talep edin<\/div>\n          <div class=\"bp-checklist-detail\">Malzeme sertifikas\u0131 + boyut uygunluk raporu<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"bp-checklist-item\">\n        <span class=\"bp-checklist-num\">2<\/span>\n        <div class=\"bp-checklist-body\">\n          <div class=\"bp-checklist-label\">Delme gerekliliklerini netle\u015ftirin<\/div>\n          <div class=\"bp-checklist-detail\">Delikli veya deliksiz; 25 mm aral\u0131klarla yerle\u015ftirilmi\u015f 6,2\u00d715 mm'lik yar\u0131klar\u0131n varl\u0131\u011f\u0131n\u0131 do\u011frulay\u0131n<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"bp-checklist-item\">\n        <span class=\"bp-checklist-num\">3<\/span>\n        <div class=\"bp-checklist-body\">\n          <div class=\"bp-checklist-label\">Malzeme s\u0131n\u0131f\u0131 teknik \u00f6zelliklerini do\u011frulay\u0131n<\/div>\n          <div class=\"bp-checklist-detail\">DC01 \u00e7eli\u011fi, \u00e7inko \u22656 \u00b5m, fabrika sertifikas\u0131nda belirtilen paslanmaz \u00e7elik s\u0131n\u0131f\u0131<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"bp-checklist-item\">\n        <span class=\"bp-checklist-num\">4<\/span>\n        <div class=\"bp-checklist-body\">\n          <div class=\"bp-checklist-label\">Uzunluklar\u0131 ve minimum sipari\u015f miktar\u0131n\u0131 teyit edin<\/div>\n          <div class=\"bp-checklist-detail\">Standart 1 m\/2 m; \u00f6zel kesim; tipik minimum sipari\u015f miktar\u0131 (MOQ) 100-500 m<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"bp-checklist-item\">\n        <span class=\"bp-checklist-num\">5<\/span>\n        <div class=\"bp-checklist-body\">\n          <div class=\"bp-checklist-label\">Ambalaj\u0131n koruyucu \u00f6zelli\u011fini kontrol edin<\/div>\n          <div class=\"bp-checklist-detail\">1 m'den uzun par\u00e7alar i\u00e7in sert ambalaj; b\u00fck\u00fclm\u00fc\u015f ray = montaj hatas\u0131<\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <p>End\u00fcstriyel da\u011f\u0131t\u0131m\u0131n ger\u00e7e\u011fi \u015fudur: DIN ray\u0131 ba\u015fl\u0131 ba\u015f\u0131na d\u00fc\u015f\u00fck k\u00e2r marjl\u0131 bir \u00fcr\u00fcnd\u00fcr. Ancak ray\u0131 bir tedarik\u00e7iden, terminal bloklar\u0131n\u0131 ba\u015fka bir tedarik\u00e7iden, r\u00f6leleri \u00fc\u00e7\u00fcnc\u00fc bir tedarik\u00e7iden ve g\u00fc\u00e7 kaynaklar\u0131n\u0131 d\u00f6rd\u00fcnc\u00fc bir tedarik\u00e7iden temin etmenin zaman maliyeti, k\u00e2r marj\u0131n\u0131z\u0131 h\u0131zla eritir. Ba\u015far\u0131l\u0131 olan distrib\u00fct\u00f6rler, konsolidasyonu ba\u015faranlard\u0131r \u2014 yani ray\u0131 ve \u00fczerine monte edilen her \u015feyi kapsayan tek bir tedarik\u00e7i ili\u015fkisi kuranlar. M\u00fc\u015fterileriniz tek bir sevkiyat ve tek bir fatura al\u0131rlar; siz de d\u00f6rt yerine tek bir tedarik\u00e7iyi y\u00f6netmekle yetinirsiniz.<\/p>\n\n    <p><em>Tedarik ortaklar\u0131n\u0131 de\u011ferlendiren distrib\u00fct\u00f6rler i\u00e7in OMCH, g\u00fc\u00e7 kaynaklar\u0131 ve MCB\u2019lerden r\u00f6lelere ve terminallere kadar DIN ray\u0131 uyumlu bile\u015fenleri kapsayan, 30\u2019dan fazla \u00fcr\u00fcn kategorisi ve 3.000\u2019den fazla SKU\u2019dan olu\u015fan bir katalog sunmaktad\u0131r. Bu, y\u00f6netmeniz gereken tedarik\u00e7i ili\u015fkilerinin say\u0131s\u0131n\u0131n azalmas\u0131 ve i\u015flemlerinizde daha fazla k\u00e2r marj\u0131 elde etmeniz anlam\u0131na gelir. \u00dcr\u00fcn yelpazesinin tamam\u0131n\u0131 \u015fu adresten inceleyin: <a href=\"https:\/\/www.omch.com\/tr\/\">www.omch.com<\/a>.<\/em><\/p>\n\n    <!-- BP-cta-end: End CTA Panel -->\n    <div class=\"bp-cta-end bd-reveal\">\n      <div class=\"bp-cta-end-left\">\n        <span class=\"bp-cta-end-icon\"><svg width=\"28\" height=\"28\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><rect x=\"2\" y=\"4\" width=\"20\" height=\"16\" rx=\"2\"\/><path d=\"m22 7-8.97 5.7a1.94 1.94 0 0 1-2.06 0L2 7\"\/><\/svg><\/span>\n        <div class=\"bp-cta-end-body\">\n          <div class=\"bp-cta-end-title\">Tedarik Zincirinizi Birle\u015ftirin<\/div>\n          <div class=\"bp-cta-end-subtitle\">Tek tedarik\u00e7i ili\u015fkisi. 30'dan fazla kategori. 3000'den fazla SKU. DIN ray\u0131 ve m\u00fc\u015fterilerinizin ihtiya\u00e7 duydu\u011fu her t\u00fcrl\u00fc bile\u015feni kar\u015f\u0131lay\u0131n \u2014 y\u00f6netmeniz gereken daha az sat\u0131n alma sipari\u015fiyle ve her i\u015flemde daha y\u00fcksek k\u00e2r marj\u0131yla.<\/div>\n        <\/div>\n      <\/div>\n      <a class=\"bp-cta-end-btn\" href=\"https:\/\/www.omch.com\/tr\/contact\/\" target=\"_self\">Fiyat Teklifi \u0130steyin <svg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" style=\"vertical-align:-3px;margin-left:4px;\"><path d=\"M5 12h14\"\/><path d=\"m12 5 7 7-7 7\"\/><\/svg><\/a>\n    <\/div>\n\n  <\/article>\n<\/div>\n<!-- \u2191\u2191\u2191 Fragment ends here. \u2191\u2191\u2191 -->\n<\/body><\/html>\n\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Standart DIN Ray\u0131 Boyut K\u0131lavuzu \u2014 Tam Boyutlar, T\u00fcrler ve Se\u00e7im Tablosu DIN Ray\u0131 Nedir? Standard\u0131 Anlamak \u0130ster panel \u00fcreticileri i\u00e7in elektrik bile\u015fenleri stokluyor olun, ister kendi projeleriniz i\u00e7in par\u00e7a se\u00e7imi yap\u0131yor olun, s\u00fcrekli olarak bir donan\u0131m par\u00e7as\u0131yla u\u011fra\u015f\u0131yorsunuz: terminal bloklar\u0131, devre kesiciler, [\u2026] gibi bile\u015fenlerin arka plakas\u0131 boyunca uzanan metal ray.<\/p>","protected":false},"author":4,"featured_media":12062,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"Standard DIN Rail Size Guide \u2014 Complete Dimensions, Types &amp; Selection Chart","_seopress_titles_desc":"Complete standard DIN rail size guide. Learn exact dimensions, tolerances, and use cases for TS35x7.5, TS35x15, TS15, and TS32 profiles per IEC 60715.","_seopress_robots_index":"","footnotes":""},"categories":[79],"tags":[],"class_list":["post-12063","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mmlblog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.omch.com\/tr\/wp-json\/wp\/v2\/posts\/12063","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.omch.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.omch.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.omch.com\/tr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.omch.com\/tr\/wp-json\/wp\/v2\/comments?post=12063"}],"version-history":[{"count":1,"href":"https:\/\/www.omch.com\/tr\/wp-json\/wp\/v2\/posts\/12063\/revisions"}],"predecessor-version":[{"id":12066,"href":"https:\/\/www.omch.com\/tr\/wp-json\/wp\/v2\/posts\/12063\/revisions\/12066"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.omch.com\/tr\/wp-json\/wp\/v2\/media\/12062"}],"wp:attachment":[{"href":"https:\/\/www.omch.com\/tr\/wp-json\/wp\/v2\/media?parent=12063"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.omch.com\/tr\/wp-json\/wp\/v2\/categories?post=12063"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.omch.com\/tr\/wp-json\/wp\/v2\/tags?post=12063"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}