{"id":7652,"date":"2025-08-27T07:22:35","date_gmt":"2025-08-27T07:22:35","guid":{"rendered":"https:\/\/www.omch.com\/?p=7652"},"modified":"2025-11-14T09:02:49","modified_gmt":"2025-11-14T09:02:49","slug":"the-power-supply-in-a-small-plc-is-often","status":"publish","type":"post","link":"https:\/\/www.omch.com\/fr\/the-power-supply-in-a-small-plc-is-often\/","title":{"rendered":"Pourquoi l'alimentation d'un petit automate est souvent de 24 V CC ?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-full is-resized\"><img alt=\"\" fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often1.webp\" class=\"wp-image-7659\" style=\"object-fit:cover;width:512px;height:384px\" srcset=\"https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often1.webp 1024w, https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often1-300x225.webp 300w, https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often1-768x576.webp 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Qu'est-ce qu'une petite API ?<\/h2>\n\n\n\n<p>Les micro-automates ou les automates programmables de type \"brique\" sont de petits contr\u00f4leurs d'automatisation qui conviennent pour ex\u00e9cuter des applications de contr\u00f4le de base. Ils sont tr\u00e8s populaires en raison de leur simplicit\u00e9, de leur faible co\u00fbt et de la facilit\u00e9 avec laquelle ils peuvent \u00eatre install\u00e9s dans des espaces potentiellement limit\u00e9s. Les petits API sont normalement fournis avec des configurations d'entr\u00e9es\/sorties (E\/S) pr\u00e9d\u00e9termin\u00e9es et des composants int\u00e9gr\u00e9s, tels que l'unit\u00e9 centrale, les bornes d'E\/S et, le plus souvent, le bloc d'alimentation.<\/p>\n\n\n\n<p>Ces petites unit\u00e9s sont courantes dans les machines d'emballage, les bandes transporteuses, les syst\u00e8mes de chauffage, de ventilation et de climatisation et les petites applications bas\u00e9es sur l'environnement de contr\u00f4le des processus. Les d\u00e9notations avec l'exigence minimale pour les op\u00e9rations logiques et o\u00f9 les contraintes environnementales jouent un r\u00f4le essentiel incluent de tels sc\u00e9narios. Cela permet de cr\u00e9er un contr\u00f4leur petit et fiable avec une installation \"plug-and-play\".<\/p>\n\n\n\n<p>Les petits automates programmables ont la particularit\u00e9 d'\u00eatre tout-en-un. Cette int\u00e9gration facilite non seulement la connexion, mais permet \u00e9galement d'\u00e9conomiser du temps de c\u00e2blage et de l'espace sur le panneau, ce qui est particuli\u00e8rement important pour les OEM et les constructeurs de machines qui souhaitent maximiser l'efficacit\u00e9 de leurs processus de fabrication. M\u00eame les petits automates continuent d'\u00eatre dot\u00e9s de fonctions sophistiqu\u00e9es, telles que le contr\u00f4le PID, les ports de communication (RS-232\/RS-485, Ethernet) et m\u00eame une capacit\u00e9 limit\u00e9e de mise en r\u00e9seau.<\/p>\n\n\n\n<p>Avant d'aborder le sujet des puissances, il est n\u00e9cessaire de comprendre la structure et le cas d'utilisation des petits automates programmables. Cette famille de contr\u00f4leurs \u00e9tant con\u00e7ue pour \u00eatre d\u00e9ploy\u00e9e dans un environnement \u00e0 alimentation \u00e9troite, la forme, la tension et l'int\u00e9gration de l'alimentation\/du bloc d'alimentation deviennent des facteurs critiques. La plupart des petits automates ont des unit\u00e9s d'alimentation internes qui respectent la norme de 24V DC, et la discussion suivante se trouve dans la section suivante.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pourquoi le 24V DC est devenu la norme<\/h2>\n\n\n\n<p>Ce n'est pas une co\u00efncidence si l'alimentation standard des petits PLC devient 24V DC, r\u00e9sultat d'ann\u00e9es de convergence dans l'automatisation industrielle dans les domaines de la s\u00e9curit\u00e9, de la compatibilit\u00e9 et de la praticit\u00e9.<\/p>\n\n\n\n<p><strong>S\u00e9curit\u00e9<\/strong><strong> Premi\u00e8rement :<\/strong> N\/a Classifie comme 24V DC est __24V DC est dans la cat\u00e9gorie Safety Extra-Low Voltage (SELV). Elle est beaucoup moins dangereuse en termes de choc \u00e9lectrique ou de risque d'incendie que les syst\u00e8mes \u00e0 tension plus \u00e9lev\u00e9e du courant alternatif. Cette cat\u00e9gorie est particuli\u00e8rement bien adapt\u00e9e \u00e0 tout environnement exposant le personnel \u00e0 des panneaux de contr\u00f4le ou \u00e0 des op\u00e9rations de maintenance.<\/p>\n\n\n\n<p><strong>L'industrie <\/strong><strong>Compatibilit\u00e9<\/strong><strong>:<\/strong> Les capteurs, actionneurs, relais et autres dispositifs auxiliaires standard de l'industrie fonctionnent \u00e0 24 V CC. Commentaire : le fait de fonctionner \u00e0 la m\u00eame tension assure une int\u00e9gration harmonieuse, r\u00e9duit l'utilisation de modules pour convertir la tension vers le bas ou vers le haut et simplifie l'architecture du syst\u00e8me.<\/p>\n\n\n\n<p><strong>Normalisation et fiabilit\u00e9 :<\/strong> Le 24V DC est devenu une sp\u00e9cification de facto utilis\u00e9e dans l'industrie de l'automatisation et les fabricants de composants ont maintenant affin\u00e9 leurs conceptions en fonction du 24V DC. Cela garantit une meilleure alimentation, une acquisition simplifi\u00e9e et des performances efficaces sur le terrain.<\/p>\n\n\n\n<p><strong>\u00c9volution historique :<\/strong> Les automates programmables ont \u00e9t\u00e9 con\u00e7us \u00e0 l'origine pour fonctionner sous diff\u00e9rentes tensions : 5V, 12V, 24V et m\u00eame 110V ! N\u00e9anmoins, la norme 24V DC est devenue le compromis le plus pratique entre l'ad\u00e9quation de la puissance et la s\u00e9curit\u00e9 de fonctionnement. Elle fournit un courant suffisant pour faire fonctionner les charges logiques et d'E\/S sans l'isolation et la protection qu'elles n\u00e9cessiteraient autrement.<\/p>\n\n\n\n<p><strong>Simplification de la distribution de l'\u00e9nergie :<\/strong> L'utilisation d'un jeu de barres pour la distribution de l'\u00e9nergie dans les armoires a \u00e9t\u00e9 centralis\u00e9e \u00e0 24V DC. Cela r\u00e9duit la complexit\u00e9 du c\u00e2blage, car une distribution d'\u00e9nergie uniforme peut \u00eatre partag\u00e9e par de nombreux composants de contr\u00f4le au m\u00eame niveau de puissance.<\/p>\n\n\n\n<p>En bref, la raison d'\u00eatre de l'adoption du 24V DC est un produit du processus historique de l'\u00e9volution du syst\u00e8me qui \u00e9quilibre l'efficacit\u00e9, l'interop\u00e9rabilit\u00e9 et la s\u00e9curit\u00e9, qui sont toutes des qualit\u00e9s essentielles des syst\u00e8mes d'automatisation industrielle actuels.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img alt=\"\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often2.webp\" class=\"wp-image-7660\" style=\"object-fit:cover;width:512px;height:384px\" srcset=\"https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often2.webp 1024w, https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often2-300x225.webp 300w, https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often2-768x576.webp 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Puissance int\u00e9gr\u00e9e : espace et simplicit\u00e9<\/h2>\n\n\n\n<p>Une autre caract\u00e9ristique majeure d'un petit automate est que l'alimentation \u00e9lectrique est incluse dans le bo\u00eetier. Il s'agit d'un m\u00e9canisme int\u00e9gr\u00e9 dont les principales motivations sont le gain de place et la simplification du processus d'installation.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Complexit\u00e9 de c\u00e2blage r\u00e9duite :<\/strong> Gr\u00e2ce au bloc d'alimentation int\u00e9gr\u00e9, les utilisateurs n'ont pas besoin de connecter un bloc d'alimentation externe. Cela r\u00e9duit les erreurs de connexion et acc\u00e9l\u00e8re le processus d'installation.<\/li>\n\n\n\n<li><strong>Panneau compact :<\/strong> Les petits automates sont souvent utilis\u00e9s dans le cadre d'une conception d'armoire de commande peu encombrante. Une unit\u00e9 d'alimentation int\u00e9gr\u00e9e permet de r\u00e9duire l'espace total du panneau.<\/li>\n\n\n\n<li><strong>Co\u00fbt inf\u00e9rieur :<\/strong> Les composants int\u00e9gr\u00e9s \u00e0 l'industrie r\u00e9duisent la nomenclature, les activit\u00e9s d'approvisionnement et le suivi des stocks.<\/li>\n<\/ul>\n\n\n\n<p>Un automate miniature typique utilise une large gamme de tensions secteur, par exemple 100-240 V CA, et la convertit en interne en 24 V CC pour faire fonctionner les circuits logiques et d'E\/S. Cette transformation interne est prise en charge par une alimentation \u00e0 d\u00e9coupage compacte int\u00e9gr\u00e9e \u00e0 la machine. Cette transformation interne est assur\u00e9e par une alimentation \u00e0 d\u00e9coupage compacte int\u00e9gr\u00e9e \u00e0 la machine.<\/p>\n\n\n\n<p>Cette conception profite \u00e9galement aux fabricants. En utilisant des alimentations int\u00e9gr\u00e9es, ils peuvent standardiser les bo\u00eetiers de leurs automates en r\u00e9duisant le nombre de connexions externes et en facilitant l'utilisation des produits pr\u00eats \u00e0 l'emploi. D'un point de vue technique, cela signifie \u00e9galement qu'il y a moins de risques de d\u00e9faillance et que le diagnostic est facilit\u00e9.<\/p>\n\n\n\n<p>Il s'agit d'un choix architectural en faveur de la tendance g\u00e9n\u00e9rale \u00e0 l'automatisation modulaire et distribu\u00e9e. Les unit\u00e9s \"plug-and-play\" permettent de configurer, de mettre en service et d'entretenir les syst\u00e8mes d'automatisation plus rapidement que par le pass\u00e9, ce qui est essentiel dans les applications d'automatisation sensibles aux co\u00fbts.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Du courant alternatif au courant continu : les dessous de la conversion<\/h2>\n\n\n\n<p>Bien que les petits automates programmables fonctionnent g\u00e9n\u00e9ralement sur 24 V CC en interne, de nombreux mod\u00e8les acceptent l'alimentation en courant alternatif en entr\u00e9e. Cela n\u00e9cessite un syst\u00e8me interne robuste de conversion de courant alternatif en courant continu, qui est g\u00e9n\u00e9ralement int\u00e9gr\u00e9 dans le bo\u00eetier.<\/p>\n\n\n\n<svg width=\"1000\" height=\"400\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n  <!-- \u80cc\u666f -->\n  <rect width=\"1000\" height=\"400\" fill=\"#f8f9fa\" stroke=\"#e9ecef\" stroke-width=\"2\"\/>\n  \n  <!-- \u6807\u9898 -->\n  <text x=\"500\" y=\"30\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"24\" font-weight=\"bold\" fill=\"#2c3e50\">AC\u8f6cDC\u7535\u6e90\u8f6c\u6362\u6d41\u7a0b\u56fe<\/text>\n  \n  <!-- AC Input -->\n  <g>\n    <!-- \u8f93\u5165\u6846 -->\n    <rect x=\"50\" y=\"80\" width=\"140\" height=\"80\" fill=\"#e3f2fd\" stroke=\"#1976d2\" stroke-width=\"2\" rx=\"5\"\/>\n    <text x=\"120\" y=\"105\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#1976d2\">AC\u8f93\u5165<\/text>\n    <text x=\"120\" y=\"125\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">100-240V<\/text>\n    <text x=\"120\" y=\"140\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">50\/60Hz<\/text>\n    \n    <!-- \u6b63\u5f26\u6ce2\u7b26\u53f7 -->\n    <path d=\"M 70 150 Q 80 145 90 150 T 110 150 Q 120 155 130 150 T 150 150 Q 160 145 170 150\" \n          stroke=\"#1976d2\" stroke-width=\"2\" fill=\"none\"\/>\n  <\/g>\n  \n  <!-- \u7bad\u59341 -->\n  <path d=\"M 200 120 L 240 120\" stroke=\"#666\" stroke-width=\"2\" marker-end=\"url(#arrowhead)\"\/>\n  \n  <!-- Rectification -->\n  <g>\n    <rect x=\"250\" y=\"80\" width=\"140\" height=\"80\" fill=\"#fff3e0\" stroke=\"#f57c00\" stroke-width=\"2\" rx=\"5\"\/>\n    <text x=\"320\" y=\"105\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#f57c00\">\u6574\u6d41 (Rectification)<\/text>\n    <text x=\"320\" y=\"125\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">\u6865\u5f0f\u6574\u6d41\u5668<\/text>\n    <text x=\"320\" y=\"140\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">\u4e8c\u6781\u7ba1\u6865<\/text>\n    \n    <!-- \u4e8c\u6781\u7ba1\u7b26\u53f7 -->\n    <g transform=\"translate(300, 150)\">\n      <polygon points=\"0,0 10,5 0,10\" fill=\"#f57c00\"\/>\n      <line x1=\"10\" y1=\"0\" x2=\"10\" y2=\"10\" stroke=\"#f57c00\" stroke-width=\"2\"\/>\n      <polygon points=\"20,0 30,5 20,10\" fill=\"#f57c00\"\/>\n      <line x1=\"30\" y1=\"0\" x2=\"30\" y2=\"10\" stroke=\"#f57c00\" stroke-width=\"2\"\/>\n    <\/g>\n  <\/g>\n  \n  <!-- \u7bad\u59342 -->\n  <path d=\"M 400 120 L 440 120\" stroke=\"#666\" stroke-width=\"2\" marker-end=\"url(#arrowhead)\"\/>\n  \n  <!-- Filtering -->\n  <g>\n    <rect x=\"450\" y=\"80\" width=\"140\" height=\"80\" fill=\"#f3e5f5\" stroke=\"#7b1fa2\" stroke-width=\"2\" rx=\"5\"\/>\n    <text x=\"520\" y=\"105\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#7b1fa2\">\u6ee4\u6ce2 (Filtrage)<\/text>\n    <text x=\"520\" y=\"125\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">\u7535\u5bb9\u6ee4\u6ce2<\/text>\n    <text x=\"520\" y=\"140\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">\u5e73\u6ed1\u7eb9\u6ce2<\/text>\n    \n    <!-- \u7535\u5bb9\u7b26\u53f7 -->\n    <g transform=\"translate(500, 150)\">\n      <line x1=\"0\" y1=\"0\" x2=\"0\" y2=\"12\" stroke=\"#7b1fa2\" stroke-width=\"2\"\/>\n      <line x1=\"5\" y1=\"0\" x2=\"5\" y2=\"12\" stroke=\"#7b1fa2\" stroke-width=\"2\"\/>\n      <line x1=\"15\" y1=\"0\" x2=\"15\" y2=\"12\" stroke=\"#7b1fa2\" stroke-width=\"2\"\/>\n      <line x1=\"20\" y1=\"0\" x2=\"20\" y2=\"12\" stroke=\"#7b1fa2\" stroke-width=\"2\"\/>\n      <line x1=\"25\" y1=\"0\" x2=\"25\" y2=\"12\" stroke=\"#7b1fa2\" stroke-width=\"2\"\/>\n      <line x1=\"30\" y1=\"0\" x2=\"30\" y2=\"12\" stroke=\"#7b1fa2\" stroke-width=\"2\"\/>\n    <\/g>\n  <\/g>\n  \n  <!-- \u7bad\u59343 -->\n  <path d=\"M 600 120 L 640 120\" stroke=\"#666\" stroke-width=\"2\" marker-end=\"url(#arrowhead)\"\/>\n  \n  <!-- Regulation -->\n  <g>\n    <rect x=\"650\" y=\"80\" width=\"140\" height=\"80\" fill=\"#e8f5e8\" stroke=\"#388e3c\" stroke-width=\"2\" rx=\"5\"\/>\n    <text x=\"720\" y=\"105\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#388e3c\">\u7a33\u538b (R\u00e8glement)<\/text>\n    <text x=\"720\" y=\"125\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">\u7ebf\u6027\/\u5f00\u5173\u7a33\u538b<\/text>\n    <text x=\"720\" y=\"140\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">\u7535\u538b\u8c03\u8282<\/text>\n    \n    <!-- \u7a33\u538b\u5668\u7b26\u53f7 -->\n    <g transform=\"translate(690, 150)\">\n      <rect x=\"0\" y=\"0\" width=\"20\" height=\"12\" fill=\"none\" stroke=\"#388e3c\" stroke-width=\"1\"\/>\n      <text x=\"10\" y=\"8\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"8\" fill=\"#388e3c\">REG<\/text>\n      <rect x=\"25\" y=\"0\" width=\"20\" height=\"12\" fill=\"none\" stroke=\"#388e3c\" stroke-width=\"1\"\/>\n      <text x=\"35\" y=\"8\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"8\" fill=\"#388e3c\">24V<\/text>\n    <\/g>\n  <\/g>\n  \n  <!-- \u7bad\u59344 -->\n  <path d=\"M 800 120 L 840 120\" stroke=\"#666\" stroke-width=\"2\" marker-end=\"url(#arrowhead)\"\/>\n  \n  <!-- DC Output -->\n  <g>\n    <rect x=\"850\" y=\"80\" width=\"140\" height=\"80\" fill=\"#ffebee\" stroke=\"#d32f2f\" stroke-width=\"2\" rx=\"5\"\/>\n    <text x=\"920\" y=\"105\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#d32f2f\">\u7a33\u5b9aDC\u8f93\u51fa<\/text>\n    <text x=\"920\" y=\"125\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">24V DC<\/text>\n    <text x=\"920\" y=\"140\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">\u7eb9\u6ce2 &lt; 1%<\/text>\n    \n    <!-- \u76f4\u6d41\u7b26\u53f7 -->\n    <g transform=\"translate(900, 150)\">\n      <line x1=\"0\" y1=\"6\" x2=\"40\" y2=\"6\" stroke=\"#d32f2f\" stroke-width=\"2\"\/>\n      <text x=\"20\" y=\"4\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"8\" fill=\"#d32f2f\">-<\/text>\n      <text x=\"10\" y=\"16\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"8\" fill=\"#d32f2f\">+<\/text>\n      <text x=\"30\" y=\"16\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"8\" fill=\"#d32f2f\">&#8211;<\/text>\n    <\/g>\n  <\/g>\n  \n  <!-- \u6ce2\u5f62\u793a\u610f\u56fe -->\n  <g transform=\"translate(50, 220)\">\n    <text x=\"0\" y=\"20\" font-family=\"Arial, sans-serif\" font-size=\"14\" font-weight=\"bold\" fill=\"#333\">\u5404\u9636\u6bb5\u6ce2\u5f62\u793a\u610f\uff1a<\/text>\n    \n    <!-- AC\u8f93\u5165\u6ce2\u5f62 -->\n    <g transform=\"translate(0, 40)\">\n      <text x=\"0\" y=\"0\" font-family=\"Arial, sans-serif\" font-size=\"10\" fill=\"#1976d2\">AC\u8f93\u5165<\/text>\n      <path d=\"M 0 15 Q 20 5 40 15 T 80 15 Q 100 25 120 15 T 160 15\" stroke=\"#1976d2\" stroke-width=\"1.5\" fill=\"none\"\/>\n    <\/g>\n    \n    <!-- \u6574\u6d41\u540e\u6ce2\u5f62 -->\n    <g transform=\"translate(200, 40)\">\n      <text x=\"0\" y=\"0\" font-family=\"Arial, sans-serif\" font-size=\"10\" fill=\"#f57c00\">\u6574\u6d41\u540e<\/text>\n      <path d=\"M 0 15 Q 20 5 40 15 L 40 15 Q 60 5 80 15 L 80 15 Q 100 5 120 15 L 120 15 Q 140 5 160 15\" stroke=\"#f57c00\" stroke-width=\"1.5\" fill=\"none\"\/>\n    <\/g>\n    \n    <!-- \u6ee4\u6ce2\u540e\u6ce2\u5f62 -->\n    <g transform=\"translate(400, 40)\">\n      <text x=\"0\" y=\"0\" font-family=\"Arial, sans-serif\" font-size=\"10\" fill=\"#7b1fa2\">\u6ee4\u6ce2\u540e<\/text>\n      <path d=\"M 0 8 Q 20 6 40 8 T 80 8 Q 100 10 120 8 T 160 8\" stroke=\"#7b1fa2\" stroke-width=\"1.5\" fill=\"none\"\/>\n    <\/g>\n    \n    <!-- \u7a33\u538b\u540e\u6ce2\u5f62 -->\n    <g transform=\"translate(600, 40)\">\n      <text x=\"0\" y=\"0\" font-family=\"Arial, sans-serif\" font-size=\"10\" fill=\"#d32f2f\">\u7a33\u538b\u540e<\/text>\n      <line x1=\"0\" y1=\"10\" x2=\"160\" y2=\"10\" stroke=\"#d32f2f\" stroke-width=\"2\"\/>\n      <text x=\"80\" y=\"6\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"8\" fill=\"#d32f2f\">24V DC<\/text>\n    <\/g>\n  <\/g>\n  \n  <!-- \u6280\u672f\u53c2\u6570\u8bf4\u660e -->\n  <g transform=\"translate(50, 320)\">\n    <text x=\"0\" y=\"0\" font-family=\"Arial, sans-serif\" font-size=\"14\" font-weight=\"bold\" fill=\"#333\">\u6280\u672f\u53c2\u6570\uff1a<\/text>\n    <text x=\"0\" y=\"20\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u8f93\u5165\u7535\u538b\uff1a100-240V AC, 50\/60Hz<\/text>\n    <text x=\"0\" y=\"35\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u8f93\u51fa\u7535\u538b\uff1a24V DC \u00b11%<\/text>\n    <text x=\"0\" y=\"50\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u7eb9\u6ce2\u7cfb\u6570\uff1a&lt; 1%<\/text>\n    \n    <text x=\"300\" y=\"20\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u8f6c\u6362\u6548\u7387\uff1a85-90%<\/text>\n    <text x=\"300\" y=\"35\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u8d1f\u8f7d\u8c03\u6574\u7387\uff1a&lt; 0.5%<\/text>\n    <text x=\"300\" y=\"50\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u7ebf\u6027\u8c03\u6574\u7387\uff1a&lt; 0.3%<\/text>\n    \n    <text x=\"600\" y=\"20\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u4fdd\u62a4\u529f\u80fd\uff1a\u8fc7\u538b\u3001\u8fc7\u6d41\u3001\u8fc7\u6e29\u4fdd\u62a4<\/text>\n    <text x=\"600\" y=\"35\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u5de5\u4f5c\u6e29\u5ea6\uff1a-10\u00b0C ~ +60\u00b0C<\/text>\n    <text x=\"600\" y=\"50\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u5b89\u5168\u6807\u51c6\uff1aCE, UL, FCC\u8ba4\u8bc1<\/text>\n  <\/g>\n  \n  <!-- \u7bad\u5934\u6807\u8bb0\u5b9a\u4e49 -->\n  <defs>\n    <marker id=\"arrowhead\" markerwidth=\"10\" markerheight=\"7\" refx=\"9\" refy=\"3.5\" orient=\"auto\">\n      <polygon points=\"0 0, 10 3.5, 0 7\" fill=\"#666\"\/>\n    <\/marker>\n  <\/defs>\n<\/svg>\n\n\n\n<h3 class=\"wp-block-heading\">Processus de conversion :<\/h3>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>Entr\u00e9e AC (100-240V) :<\/strong> L'appareil est connect\u00e9 \u00e0 une alimentation \u00e9lectrique standard.<\/li>\n\n\n\n<li><strong>Rectification :<\/strong> Le courant alternatif (CA) est converti en courant continu non r\u00e9gul\u00e9 \u00e0 l'aide d'un pont redresseur.<\/li>\n\n\n\n<li><strong>Filtrage :<\/strong> Les condensateurs lissent le signal redress\u00e9 pour r\u00e9duire l'ondulation.<\/li>\n\n\n\n<li><strong>R\u00e8glement :<\/strong> Un r\u00e9gulateur de tension assure une sortie stable de 24 V CC, quelles que soient les fluctuations de la charge.<\/li>\n<\/ol>\n\n\n\n<p>Les automates modernes utilisent des alimentations \u00e0 d\u00e9coupage au lieu de r\u00e9gulateurs lin\u00e9aires. Ces derniers sont plus compacts, plus efficaces et g\u00e9n\u00e8rent moins de chaleur, ce qui est essentiel pour les syst\u00e8mes ferm\u00e9s et sans ventilateur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Compatibilit\u00e9 double entr\u00e9e<\/h3>\n\n\n\n<p>D'autres types d'automates acceptent les entr\u00e9es en courant alternatif et en courant continu et offrent donc une plus grande flexibilit\u00e9 dans les diff\u00e9rents arrangements \u00e9lectriques. Dans ce cas, les circuits internes sont programm\u00e9s pour d\u00e9tecter automatiquement le type d'entr\u00e9e et s'y adapter, ce qui rend le processus d'utilisation transparent.<\/p>\n\n\n\n<p>Cette conception offrira une transition sophistiqu\u00e9e entre les solutions bas\u00e9es sur le courant alternatif et le courant continu du pass\u00e9 et les architectures de contr\u00f4le bas\u00e9es sur le courant continu de l'avenir. Cela signifie \u00e9galement que m\u00eame dans les installations o\u00f9 le 24V DC n'est pas normalement distribu\u00e9, les PLC peuvent \u00eatre install\u00e9s sans qu'il soit n\u00e9cessaire d'incorporer des alimentations externes s\u00e9par\u00e9es dans l'installation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Choisir la bonne capacit\u00e9 d'alimentation<\/h2>\n\n\n\n<p>Le choix d'un automate ayant une puissance nominale appropri\u00e9e est essentiel pour \u00e9viter les chutes de tension, les surcharges ou les performances insuffisantes. La charge totale du syst\u00e8me doit \u00eatre calcul\u00e9e en fonction du courant absorb\u00e9 par les circuits internes et les dispositifs externes aliment\u00e9s par l'automate.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Facteurs cl\u00e9s \u00e0 prendre en compte :<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Charge totale d'E\/S :<\/strong> Somme de tous les dispositifs d'entr\u00e9e et de sortie connect\u00e9s, y compris les relais, les sol\u00e9no\u00efdes, les capteurs, etc.<\/li>\n\n\n\n<li><strong>Courant d'appel au d\u00e9marrage :<\/strong> Les appareils tels que les \u00e9lectrovannes ou les moteurs peuvent tirer momentan\u00e9ment un courant plus \u00e9lev\u00e9 au d\u00e9marrage.<\/li>\n\n\n\n<li><strong>R\u00e9serve de marche :<\/strong> Il faut toujours pr\u00e9voir un tampon - 20% est courant - pour faire face \u00e0 une expansion future ou \u00e0 des fluctuations de puissance.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Exemple de tableau de budget \u00e9nerg\u00e9tique<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Type d'appareil<\/td><td>Quantit\u00e9<\/td><td>Courant par dispositif (mA)<\/td><td>Courant total (mA)<\/td><\/tr><tr><td>Capteurs de proximit\u00e9<\/td><td>4<\/td><td>15<\/td><td>60<\/td><\/tr><tr><td>Voyants lumineux<\/td><td>3<\/td><td>20<\/td><td>60<\/td><\/tr><tr><td>Sorties relais<\/td><td>6<\/td><td>40<\/td><td>240<\/td><\/tr><tr><td>Circuit logique PLC<\/td><td>1<\/td><td>150<\/td><td>150<\/td><\/tr><tr><td>Total<\/td><td><\/td><td><\/td><td>510<\/td><\/tr><tr><td>+20% Tampon<\/td><td><\/td><td><\/td><td>612 mA<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Dans cet exemple, un automate ayant au moins <strong>0,7A (700mA)<\/strong> de la capacit\u00e9 d'alimentation en courant continu de 24 V serait souhaitable.<\/p>\n\n\n\n<p>Certains petits automates permettent d'appliquer s\u00e9par\u00e9ment une alimentation externe de 24 V aux bornes d'E\/S, ce qui soulage l'alimentation interne. Conna\u00eetre son architecture permet d'\u00e9viter les sursp\u00e9cifications ou les contraintes sur les composants.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">D\u00e9pannage des probl\u00e8mes d'alimentation \u00e9lectrique<\/h2>\n\n\n\n<p>Malgr\u00e9 leur fiabilit\u00e9, les petits automates programmables peuvent rencontrer des probl\u00e8mes d'alimentation qui peuvent perturber les processus d'automatisation. Il est essentiel d'identifier et de r\u00e9soudre rapidement ces probl\u00e8mes afin de minimiser les temps d'arr\u00eat.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Sympt\u00f4mes courants :<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Le voyant d'alimentation n'est pas allum\u00e9 :<\/strong> Indique l'absence de tension d'alimentation ou une panne de courant interne<\/li>\n\n\n\n<li><strong>R\u00e9initialisations inattendues :<\/strong> Peut \u00eatre caus\u00e9 par une tension d'alimentation intermittente<\/li>\n\n\n\n<li><strong>D\u00e9fauts d'entr\u00e9e\/sortie :<\/strong> Peut se produire si la tension chute sous l'effet de la charge<\/li>\n\n\n\n<li><strong>Erreurs de communication :<\/strong> Une mauvaise r\u00e9gulation de la tension peut avoir un impact sur les bus internes<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Liste de contr\u00f4le pour le d\u00e9pannage :<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>V\u00e9rifier que la tension d'entr\u00e9e se situe dans la plage sp\u00e9cifi\u00e9e (par exemple, 100-240 V CA).<\/li>\n\n\n\n<li>Mesurer la tension de sortie en courant continu entre les bornes internes, si elles sont accessibles.<\/li>\n\n\n\n<li>V\u00e9rifier que les connexions des bornes ne sont pas desserr\u00e9es et qu'il n'y a pas de signes de corrosion.<\/li>\n\n\n\n<li>Confirmer que la mise \u00e0 la terre est s\u00fbre et correcte<\/li>\n\n\n\n<li>V\u00e9rifier la temp\u00e9rature ambiante - une surchauffe peut d\u00e9clencher un arr\u00eat de protection<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Meilleures pratiques de c\u00e2blage :<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Utiliser des fils de calibre appropri\u00e9 pour la puissance d'entr\u00e9e<\/li>\n\n\n\n<li>Mettez l'automate \u00e0 la terre conform\u00e9ment aux sp\u00e9cifications du fabricant.<\/li>\n\n\n\n<li>\u00c9viter d'acheminer les lignes d'alimentation et de signal en parall\u00e8le<\/li>\n<\/ul>\n\n\n\n<p>En maintenant une alimentation propre et r\u00e9gul\u00e9e et en respectant les proc\u00e9dures d'installation appropri\u00e9es, la plupart des probl\u00e8mes d'alimentation peuvent \u00eatre \u00e9vit\u00e9s. Consultez la documentation du fabricant pour obtenir des diagnostics d\u00e9taill\u00e9s et des proc\u00e9dures de remplacement.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Quand utiliser des modules d'alimentation externes<\/h2>\n\n\n\n<p>Si les alimentations int\u00e9gr\u00e9es sont id\u00e9ales pour les petits automates dans des sc\u00e9narios de charge faible \u00e0 moyenne, certaines applications exigent une plus grande flexibilit\u00e9 ou capacit\u00e9 - c'est l\u00e0 que les modules d'alimentation externes entrent en jeu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Quand les modules externes prennent tout leur sens :<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Haut <\/strong><strong>E\/S<\/strong><strong> Charge :<\/strong> Les syst\u00e8mes comportant des dizaines de sorties peuvent d\u00e9passer les limites de l'alimentation interne.<\/li>\n\n\n\n<li><strong>Exigences en mati\u00e8re de redondance :<\/strong> Les op\u00e9rations critiques utilisent souvent des entr\u00e9es d'alimentation doubles ou des alimentations rempla\u00e7ables \u00e0 chaud.<\/li>\n\n\n\n<li><strong>Architectures modulaires d'automates :<\/strong> Ceux-ci s\u00e9parent souvent l'unit\u00e9 centrale, les entr\u00e9es\/sorties et les unit\u00e9s d'alimentation pour une meilleure \u00e9volutivit\u00e9.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Avantages des alimentations externes :<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00c9volutif : Choisissez les modules d'alimentation qui correspondent exactement aux besoins du syst\u00e8me<\/li>\n\n\n\n<li>Isol\u00e9es : R\u00e9duit le bruit et les interf\u00e9rences dans les circuits sensibles<\/li>\n\n\n\n<li>R\u00e9alisable : Facile \u00e0 remplacer ou \u00e0 mettre \u00e0 niveau sans affecter le c\u0153ur de l'automate.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Compromis :<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Augmentation de la complexit\u00e9 et de la taille des panneaux<\/li>\n\n\n\n<li>N\u00e9cessite une planification et un c\u00e2blage suppl\u00e9mentaires<\/li>\n\n\n\n<li>Augmente le co\u00fbt total du syst\u00e8me<\/li>\n<\/ul>\n\n\n\n<p>Si votre application est complexe, implique des extensions fr\u00e9quentes ou fonctionne dans des conditions difficiles, il peut \u00eatre int\u00e9ressant d'explorer les options d'automates modulaires dot\u00e9s de capacit\u00e9s d'alimentation externe.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Composants d'automatisation de confiance d'OMCH<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img alt=\"\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/D-30-1.webp\" class=\"wp-image-7574\" style=\"object-fit:cover;width:512px;height:512px\" srcset=\"https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/D-30-1.webp 600w, https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/D-30-1-300x300.webp 300w, https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/D-30-1-150x150.webp 150w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure>\n\n\n\n<p>Avec plus de 30 ans d'exp\u00e9rience dans l'industrie, OMCH est un fournisseur fiable de composants d'automatisation depuis 1986. Des alimentations aux capteurs et aux \u00e9l\u00e9ments pneumatiques, notre gamme de produits prend en charge un large \u00e9ventail de syst\u00e8mes \u00e0 base d'automates programmables.<\/p>\n\n\n\n<p>Nos composants sont certifi\u00e9s ISO 9001, CE, CCC et RoHS, ce qui garantit leur conformit\u00e9 et leur fiabilit\u00e9 sur les march\u00e9s mondiaux. Pour les projets n\u00e9cessitant des conceptions personnalis\u00e9es ou des solutions OEM, OMCH propose une fabrication flexible pour r\u00e9pondre aux besoins techniques et d'int\u00e9gration sp\u00e9cifiques.<\/p>\n\n\n\n<p>Que vous recherchiez des modules d'alimentation compacts ou que vous planifiez un syst\u00e8me de contr\u00f4le \u00e9volutif, OMCH vous offre une qualit\u00e9 constante et une assistance fiable.<\/p>\n\n\n\n<p>Pour en savoir plus <strong><a href=\"https:\/\/www.omch.com\/fr\/\">omch.com<\/a><\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p>L'objectif de l'utilisation du 24V DC se situe entre la s\u00e9curit\u00e9, la standardisation et la simplicit\u00e9 du syst\u00e8me. Il est toujours important d'utiliser des alimentations int\u00e9gr\u00e9es et une optimisation efficace de la capacit\u00e9 afin que ces contr\u00f4leurs compacts puissent rester la pierre angulaire d'une automatisation efficace et fiable.<\/p>\n\n\n\n<p>Pour l'ing\u00e9nieur ou l'int\u00e9grateur, la connaissance de l'architecture de puissance d'un automate est plus qu'une sp\u00e9cification ; elle est fondamentale pour la stabilit\u00e9, l'\u00e9volutivit\u00e9 et la s\u00e9curit\u00e9 du syst\u00e8me. Et lorsque toutes les pi\u00e8ces comptent, il est judicieux de faire appel \u00e0 des fabricants de confiance, tels qu'OMCH.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Qu'est-ce qu'un petit automate programmable ? Les micro-automates programmables ou les automates programmables de type \"brique\" sont de petits contr\u00f4leurs d'automatisation qui conviennent pour ex\u00e9cuter des applications de contr\u00f4le de base. Ils sont tr\u00e8s populaires en raison de leur simplicit\u00e9, de leur faible co\u00fbt et de la facilit\u00e9 avec laquelle ils peuvent \u00eatre install\u00e9s dans des espaces potentiellement limit\u00e9s. Les petits automates sont normalement fournis avec des configurations d'entr\u00e9es\/sorties (E\/S) pr\u00e9d\u00e9termin\u00e9es et des composants int\u00e9gr\u00e9s, tels que [...]<\/p>","protected":false},"author":4,"featured_media":7659,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"Why the Power Supply in a Small PLC Is Often 24V DC","_seopress_titles_desc":"Discover why the power supply in a small PLC is often 24V DC. Our blog explores its benefits and applications in automation systems.","_seopress_robots_index":"","footnotes":""},"categories":[44],"tags":[],"class_list":["post-7652","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-supply"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.omch.com\/fr\/wp-json\/wp\/v2\/posts\/7652","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.omch.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.omch.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.omch.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.omch.com\/fr\/wp-json\/wp\/v2\/comments?post=7652"}],"version-history":[{"count":3,"href":"https:\/\/www.omch.com\/fr\/wp-json\/wp\/v2\/posts\/7652\/revisions"}],"predecessor-version":[{"id":8786,"href":"https:\/\/www.omch.com\/fr\/wp-json\/wp\/v2\/posts\/7652\/revisions\/8786"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.omch.com\/fr\/wp-json\/wp\/v2\/media\/7659"}],"wp:attachment":[{"href":"https:\/\/www.omch.com\/fr\/wp-json\/wp\/v2\/media?parent=7652"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.omch.com\/fr\/wp-json\/wp\/v2\/categories?post=7652"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.omch.com\/fr\/wp-json\/wp\/v2\/tags?post=7652"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}