{"id":7652,"date":"2025-08-27T07:22:35","date_gmt":"2025-08-27T07:22:35","guid":{"rendered":"https:\/\/www.omch.com\/?p=7652"},"modified":"2025-11-14T09:02:49","modified_gmt":"2025-11-14T09:02:49","slug":"the-power-supply-in-a-small-plc-is-often","status":"publish","type":"post","link":"https:\/\/www.omch.com\/es\/the-power-supply-in-a-small-plc-is-often\/","title":{"rendered":"Por qu\u00e9 la fuente de alimentaci\u00f3n de un PLC peque\u00f1o suele ser de 24 V CC"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-full is-resized\"><img alt=\"\" fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often1.webp\" class=\"wp-image-7659\" style=\"object-fit:cover;width:512px;height:384px\" srcset=\"https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often1.webp 1024w, https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often1-300x225.webp 300w, https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often1-768x576.webp 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u00bfQu\u00e9 es una peque\u00f1a sociedad an\u00f3nima?<\/h2>\n\n\n\n<p>Los microprocesadores o aut\u00f3matas programables de tipo ladrillo son peque\u00f1os controladores de automatizaci\u00f3n adecuados para ejecutar aplicaciones de control b\u00e1sicas. Su naturaleza simplista, su bajo precio y la comodidad de instalarlos en espacios potencialmente limitados los hacen muy populares. Los PLC peque\u00f1os se suministran normalmente con configuraciones predeterminadas de entrada\/salida (E\/S) y componentes integrados, como la CPU, los terminales de E\/S y, en la mayor\u00eda de los casos, la fuente de alimentaci\u00f3n.<\/p>\n\n\n\n<p>Estas unidades de peque\u00f1o tama\u00f1o son habituales en m\u00e1quinas de envasado, cintas transportadoras, sistemas HVAC y peque\u00f1as aplicaciones basadas en entornos de control de procesos. Entre las denotaciones con requisitos m\u00ednimos para las operaciones l\u00f3gicas y en las que las restricciones medioambientales desempe\u00f1an un papel esencial se incluyen estos escenarios. Esto crea un controlador peque\u00f1o y fiable con una instalaci\u00f3n plug-and-play.<\/p>\n\n\n\n<p>Los PLC peque\u00f1os tienen como rasgo definitivo la caracter\u00edstica de \"todo en uno\". Esta integraci\u00f3n no s\u00f3lo facilita la conexi\u00f3n, sino que ahorra tiempo de cableado, as\u00ed como espacio en el panel, una consideraci\u00f3n especialmente importante para OEM y fabricantes de maquinaria que desean maximizar la eficiencia de sus procesos de fabricaci\u00f3n. El factor de forma reducido no impide la funcionalidad Incluso los PLC peque\u00f1os siguen disponiendo de funciones sofisticadas, como control PID, puertos de comunicaci\u00f3n (RS-232\/RS-485, Ethernet) e incluso capacidad limitada de conexi\u00f3n en red.<\/p>\n\n\n\n<p>Antes de continuar con el tema de las potencias, es necesario comprender la estructura y el caso de uso de los PLC peque\u00f1os. Dado que esta familia de controladores se ha dise\u00f1ado para utilizarse en un entorno con una fuente de alimentaci\u00f3n reducida, la forma, el voltaje y la integraci\u00f3n de la fuente de alimentaci\u00f3n se convierten en factores cr\u00edticos. La mayor\u00eda de los PLC peque\u00f1os tienen las unidades de alimentaci\u00f3n internas que se adhieren a la norma de 24V DC, y la siguiente discusi\u00f3n se encuentra en la siguiente secci\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Por qu\u00e9 se ha impuesto la corriente continua de 24 V<\/h2>\n\n\n\n<p>No es casualidad que la fuente de alimentaci\u00f3n est\u00e1ndar de los peque\u00f1os PLC se est\u00e9 convirtiendo en 24 V CC; el resultado de a\u00f1os de convergencia en la automatizaci\u00f3n industrial en los \u00e1mbitos de la seguridad, la compatibilidad y la practicidad.<\/p>\n\n\n\n<p><strong>Seguridad<\/strong><strong> Primero:<\/strong> N\/a Clasifica como 24V DC es __24V DC est\u00e1 bajo la categor\u00eda Safety Extra-Low Voltage (SELV). Es mucho menos peligrosa en t\u00e9rminos de descarga el\u00e9ctrica o peligro de incendio que los sistemas con tensiones m\u00e1s altas de la CA. Es especialmente adecuado para cualquier entorno que exponga al personal a paneles de control o mantenimiento.<\/p>\n\n\n\n<p><strong>Industria <\/strong><strong>Compatibilidad<\/strong><strong>:<\/strong> Los sensores, actuadores, rel\u00e9s y dem\u00e1s dispositivos auxiliares est\u00e1ndar del sector funcionan a 24 V CC. Comentario: funcionar con la misma tensi\u00f3n garantizar\u00e1 una integraci\u00f3n sin problemas, un menor uso de m\u00f3dulos para convertir la tensi\u00f3n hacia abajo o hacia arriba y la simplificaci\u00f3n de la arquitectura del sistema.<\/p>\n\n\n\n<p><strong>Normalizaci\u00f3n y fiabilidad:<\/strong> La corriente continua de 24 V se ha convertido en una especificaci\u00f3n de facto utilizada en la industria de la automatizaci\u00f3n y los fabricantes de componentes ya han perfeccionado sus dise\u00f1os a 24 V CC. Garantiza un suministro mejorado, una adquisici\u00f3n simplificada y un rendimiento eficaz sobre el terreno.<\/p>\n\n\n\n<p><strong>Evoluci\u00f3n hist\u00f3rica:<\/strong> Los PLC se dise\u00f1aron originalmente para funcionar con distintos voltajes: PLC de 5 V, PLC de 12 V, PLC de 24 V, \u00a1incluso de 110 V! Sin embargo, el est\u00e1ndar de 24V CC se convirti\u00f3 en el compromiso m\u00e1s conveniente entre la adecuaci\u00f3n de la potencia y la seguridad de funcionamiento. Suministra corriente suficiente para hacer funcionar las cargas l\u00f3gicas y de E\/S sin el aislamiento y la protecci\u00f3n que de otro modo ser\u00edan necesarios.<\/p>\n\n\n\n<p><strong>Simplificaci\u00f3n de la distribuci\u00f3n de energ\u00eda:<\/strong> El uso de barras colectoras para la distribuci\u00f3n de energ\u00eda a los requisitos de potencia en los armarios se ha centralizado a 24 V CC. Esto disminuye la complejidad del cableado, ya que una distribuci\u00f3n de potencia uniforme puede ser compartida por muchos componentes de control en el mismo nivel de potencia.<\/p>\n\n\n\n<p>En pocas palabras, la justificaci\u00f3n de la adopci\u00f3n de 24 V CC es producto del proceso hist\u00f3rico de evoluci\u00f3n del sistema que equilibra eficacia, interoperabilidad y seguridad, cualidades esenciales descritas en los actuales sistemas de automatizaci\u00f3n industrial.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img alt=\"\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often2.webp\" class=\"wp-image-7660\" style=\"object-fit:cover;width:512px;height:384px\" srcset=\"https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often2.webp 1024w, https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often2-300x225.webp 300w, https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/the-power-supply-in-a-small-plc-is-often2-768x576.webp 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Potencia integrada: espacio y sencillez<\/h2>\n\n\n\n<p>Otra de las caracter\u00edsticas m\u00e1s destacadas de un PLC peque\u00f1o es que tiene la fuente de alimentaci\u00f3n incluida en la carcasa. Se trata de un mecanismo incorporado entre cuyos principales motivos figuran el ahorro de espacio y la simplificaci\u00f3n del proceso de instalaci\u00f3n.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Menor complejidad del cableado:<\/strong> Con la fuente de alimentaci\u00f3n integrada, los usuarios no necesitan conectar una fuente de alimentaci\u00f3n externa. Esto reduce los errores de conexi\u00f3n y acelera el proceso de configuraci\u00f3n.<\/li>\n\n\n\n<li><strong>Dise\u00f1o de panel compacto:<\/strong> El uso de PLC peque\u00f1os suele obedecer a un dise\u00f1o de armario de control que ahorra espacio. Una unidad de potencia incorporada ayudar\u00e1 a disminuir todo el espacio del panel.<\/li>\n\n\n\n<li><strong>Menor coste:<\/strong> Los componentes integrados en la industria reducen la lista de materiales, la actividad de aprovisionamiento y el seguimiento del inventario.<\/li>\n<\/ul>\n\n\n\n<p>Un PLC en miniatura t\u00edpico tomar\u00eda una amplia gama de tensiones de alimentaci\u00f3n de CA, por ejemplo 100-240 V CA, y la convertir\u00eda internamente en 24 V CC para hacer funcionar los circuitos l\u00f3gicos y de E\/S. Esta transformaci\u00f3n interna se realiza mediante una fuente de alimentaci\u00f3n conmutada compacta integrada en la m\u00e1quina. De esta transformaci\u00f3n interna se encarga una fuente de alimentaci\u00f3n conmutada compacta integrada en la m\u00e1quina.<\/p>\n\n\n\n<p>Este dise\u00f1o tambi\u00e9n beneficia a los fabricantes. Al utilizar fuentes de alimentaci\u00f3n integradas, pueden estandarizar sus envolventes de PLC al tener menos conexiones externas y son m\u00e1s f\u00e1ciles de usar desde el primer momento. Desde el punto de vista t\u00e9cnico, esto tambi\u00e9n significa que hay menos posibilidades de que se produzcan fallos y se facilita el diagn\u00f3stico.<\/p>\n\n\n\n<p>Se trata de una opci\u00f3n arquitect\u00f3nica que favorece la tendencia general hacia la automatizaci\u00f3n modular y distribuida. Las unidades \"plug-and-play\" permiten configurar, poner en servicio y realizar el mantenimiento de los sistemas de automatizaci\u00f3n con mayor rapidez que en el pasado, algo esencial en aplicaciones de automatizaci\u00f3n sensibles a los costes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">De CA a CC: la conversi\u00f3n por dentro<\/h2>\n\n\n\n<p>Aunque los PLC peque\u00f1os suelen funcionar internamente con 24 V CC, muchos modelos aceptan alimentaci\u00f3n de CA como entrada. Esto requiere un robusto sistema interno de conversi\u00f3n de CA a CC, que suele estar integrado en la carcasa.<\/p>\n\n\n\n<svg width=\"1000\" height=\"400\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n  <!-- \u80cc\u666f -->\n  <rect width=\"1000\" height=\"400\" fill=\"#f8f9fa\" stroke=\"#e9ecef\" stroke-width=\"2\"\/>\n  \n  <!-- \u6807\u9898 -->\n  <text x=\"500\" y=\"30\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"24\" font-weight=\"bold\" fill=\"#2c3e50\">AC\u8f6cDC\u7535\u6e90\u8f6c\u6362\u6d41\u7a0b\u56fe<\/text>\n  \n  <!-- AC Input -->\n  <g>\n    <!-- \u8f93\u5165\u6846 -->\n    <rect x=\"50\" y=\"80\" width=\"140\" height=\"80\" fill=\"#e3f2fd\" stroke=\"#1976d2\" stroke-width=\"2\" rx=\"5\"\/>\n    <text x=\"120\" y=\"105\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#1976d2\">AC8F93\u21a9\u5165<\/text>\n    <text x=\"120\" y=\"125\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">100-240V<\/text>\n    <text x=\"120\" y=\"140\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">50\/60 Hz<\/text>\n    \n    <!-- \u6b63\u5f26\u6ce2\u7b26\u53f7 -->\n    <path d=\"M 70 150 Q 80 145 90 150 T 110 150 Q 120 155 130 150 T 150 150 Q 160 145 170 150\" \n          stroke=\"#1976d2\" stroke-width=\"2\" fill=\"none\"\/>\n  <\/g>\n  \n  <!-- \u7bad\u59341 -->\n  <path d=\"M 200 120 L 240 120\" stroke=\"#666\" stroke-width=\"2\" marker-end=\"url(#arrowhead)\"\/>\n  \n  <!-- Rectification -->\n  <g>\n    <rect x=\"250\" y=\"80\" width=\"140\" height=\"80\" fill=\"#fff3e0\" stroke=\"#f57c00\" stroke-width=\"2\" rx=\"5\"\/>\n    <text x=\"320\" y=\"105\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#f57c00\">\u6574\u6d41 (Rectificaci\u00f3n)<\/text>\n    <text x=\"320\" y=\"125\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">\u6865\u5f0f\u6574\u6d41\u5668<\/text>\n    <text x=\"320\" y=\"140\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">\u4e8c\u6781\u7ba1\u6865<\/text>\n    \n    <!-- \u4e8c\u6781\u7ba1\u7b26\u53f7 -->\n    <g transform=\"translate(300, 150)\">\n      <polygon points=\"0,0 10,5 0,10\" fill=\"#f57c00\"\/>\n      <line x1=\"10\" y1=\"0\" x2=\"10\" y2=\"10\" stroke=\"#f57c00\" stroke-width=\"2\"\/>\n      <polygon points=\"20,0 30,5 20,10\" fill=\"#f57c00\"\/>\n      <line x1=\"30\" y1=\"0\" x2=\"30\" y2=\"10\" stroke=\"#f57c00\" stroke-width=\"2\"\/>\n    <\/g>\n  <\/g>\n  \n  <!-- \u7bad\u59342 -->\n  <path d=\"M 400 120 L 440 120\" stroke=\"#666\" stroke-width=\"2\" marker-end=\"url(#arrowhead)\"\/>\n  \n  <!-- Filtering -->\n  <g>\n    <rect x=\"450\" y=\"80\" width=\"140\" height=\"80\" fill=\"#f3e5f5\" stroke=\"#7b1fa2\" stroke-width=\"2\" rx=\"5\"\/>\n    <text x=\"520\" y=\"105\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#7b1fa2\">\u6ee4\u6ce2 (Filtrado)<\/text>\n    <text x=\"520\" y=\"125\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">\u7535\u5bb9\u6ee4\u6ce2<\/text>\n    <text x=\"520\" y=\"140\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">\u5e73\u6ed1\u7eb9\u6ce2<\/text>\n    \n    <!-- \u7535\u5bb9\u7b26\u53f7 -->\n    <g transform=\"translate(500, 150)\">\n      <line x1=\"0\" y1=\"0\" x2=\"0\" y2=\"12\" stroke=\"#7b1fa2\" stroke-width=\"2\"\/>\n      <line x1=\"5\" y1=\"0\" x2=\"5\" y2=\"12\" stroke=\"#7b1fa2\" stroke-width=\"2\"\/>\n      <line x1=\"15\" y1=\"0\" x2=\"15\" y2=\"12\" stroke=\"#7b1fa2\" stroke-width=\"2\"\/>\n      <line x1=\"20\" y1=\"0\" x2=\"20\" y2=\"12\" stroke=\"#7b1fa2\" stroke-width=\"2\"\/>\n      <line x1=\"25\" y1=\"0\" x2=\"25\" y2=\"12\" stroke=\"#7b1fa2\" stroke-width=\"2\"\/>\n      <line x1=\"30\" y1=\"0\" x2=\"30\" y2=\"12\" stroke=\"#7b1fa2\" stroke-width=\"2\"\/>\n    <\/g>\n  <\/g>\n  \n  <!-- \u7bad\u59343 -->\n  <path d=\"M 600 120 L 640 120\" stroke=\"#666\" stroke-width=\"2\" marker-end=\"url(#arrowhead)\"\/>\n  \n  <!-- Regulation -->\n  <g>\n    <rect x=\"650\" y=\"80\" width=\"140\" height=\"80\" fill=\"#e8f5e8\" stroke=\"#388e3c\" stroke-width=\"2\" rx=\"5\"\/>\n    <text x=\"720\" y=\"105\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#388e3c\">\u7a33\u538b (Reglamento)<\/text>\n    <text x=\"720\" y=\"125\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">\u7ebf\u6027\/\u5f00\u5173\u7a33\u538b<\/text>\n    <text x=\"720\" y=\"140\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">\u7535\u538b\u8c03\u8282<\/text>\n    \n    <!-- \u7a33\u538b\u5668\u7b26\u53f7 -->\n    <g transform=\"translate(690, 150)\">\n      <rect x=\"0\" y=\"0\" width=\"20\" height=\"12\" fill=\"none\" stroke=\"#388e3c\" stroke-width=\"1\"\/>\n      <text x=\"10\" y=\"8\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"8\" fill=\"#388e3c\">REG<\/text>\n      <rect x=\"25\" y=\"0\" width=\"20\" height=\"12\" fill=\"none\" stroke=\"#388e3c\" stroke-width=\"1\"\/>\n      <text x=\"35\" y=\"8\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"8\" fill=\"#388e3c\">24V<\/text>\n    <\/g>\n  <\/g>\n  \n  <!-- \u7bad\u59344 -->\n  <path d=\"M 800 120 L 840 120\" stroke=\"#666\" stroke-width=\"2\" marker-end=\"url(#arrowhead)\"\/>\n  \n  <!-- DC Output -->\n  <g>\n    <rect x=\"850\" y=\"80\" width=\"140\" height=\"80\" fill=\"#ffebee\" stroke=\"#d32f2f\" stroke-width=\"2\" rx=\"5\"\/>\n    <text x=\"920\" y=\"105\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#d32f2f\">\u7a33\u5b9aDC\u8f93\u51fa<\/text>\n    <text x=\"920\" y=\"125\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">24 V CC<\/text>\n    <text x=\"920\" y=\"140\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#333\">\u7eb9\u6ce2 &lt; 1%<\/text>\n    \n    <!-- \u76f4\u6d41\u7b26\u53f7 -->\n    <g transform=\"translate(900, 150)\">\n      <line x1=\"0\" y1=\"6\" x2=\"40\" y2=\"6\" stroke=\"#d32f2f\" stroke-width=\"2\"\/>\n      <text x=\"20\" y=\"4\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"8\" fill=\"#d32f2f\">-<\/text>\n      <text x=\"10\" y=\"16\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"8\" fill=\"#d32f2f\">+<\/text>\n      <text x=\"30\" y=\"16\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"8\" fill=\"#d32f2f\">&#8211;<\/text>\n    <\/g>\n  <\/g>\n  \n  <!-- \u6ce2\u5f62\u793a\u610f\u56fe -->\n  <g transform=\"translate(50, 220)\">\n    <text x=\"0\" y=\"20\" font-family=\"Arial, sans-serif\" font-size=\"14\" font-weight=\"bold\" fill=\"#333\">\u5404\u9636\u6bb5\u6ce2\u5f62\u793a\u610f\uff1a<\/text>\n    \n    <!-- AC\u8f93\u5165\u6ce2\u5f62 -->\n    <g transform=\"translate(0, 40)\">\n      <text x=\"0\" y=\"0\" font-family=\"Arial, sans-serif\" font-size=\"10\" fill=\"#1976d2\">AC8F93\u21a9\u5165<\/text>\n      <path d=\"M 0 15 Q 20 5 40 15 T 80 15 Q 100 25 120 15 T 160 15\" stroke=\"#1976d2\" stroke-width=\"1.5\" fill=\"none\"\/>\n    <\/g>\n    \n    <!-- \u6574\u6d41\u540e\u6ce2\u5f62 -->\n    <g transform=\"translate(200, 40)\">\n      <text x=\"0\" y=\"0\" font-family=\"Arial, sans-serif\" font-size=\"10\" fill=\"#f57c00\">\u6574\u6d41\u540e<\/text>\n      <path d=\"M 0 15 Q 20 5 40 15 L 40 15 Q 60 5 80 15 L 80 15 Q 100 5 120 15 L 120 15 Q 140 5 160 15\" stroke=\"#f57c00\" stroke-width=\"1.5\" fill=\"none\"\/>\n    <\/g>\n    \n    <!-- \u6ee4\u6ce2\u540e\u6ce2\u5f62 -->\n    <g transform=\"translate(400, 40)\">\n      <text x=\"0\" y=\"0\" font-family=\"Arial, sans-serif\" font-size=\"10\" fill=\"#7b1fa2\">\u6ee4\u6ce2\u540e<\/text>\n      <path d=\"M 0 8 Q 20 6 40 8 T 80 8 Q 100 10 120 8 T 160 8\" stroke=\"#7b1fa2\" stroke-width=\"1.5\" fill=\"none\"\/>\n    <\/g>\n    \n    <!-- \u7a33\u538b\u540e\u6ce2\u5f62 -->\n    <g transform=\"translate(600, 40)\">\n      <text x=\"0\" y=\"0\" font-family=\"Arial, sans-serif\" font-size=\"10\" fill=\"#d32f2f\">\u7a33\u538b\u540e<\/text>\n      <line x1=\"0\" y1=\"10\" x2=\"160\" y2=\"10\" stroke=\"#d32f2f\" stroke-width=\"2\"\/>\n      <text x=\"80\" y=\"6\" text-anchor=\"middle\" font-family=\"Arial, sans-serif\" font-size=\"8\" fill=\"#d32f2f\">24 V CC<\/text>\n    <\/g>\n  <\/g>\n  \n  <!-- \u6280\u672f\u53c2\u6570\u8bf4\u660e -->\n  <g transform=\"translate(50, 320)\">\n    <text x=\"0\" y=\"0\" font-family=\"Arial, sans-serif\" font-size=\"14\" font-weight=\"bold\" fill=\"#333\">\u6280\u672f\u53c2\u6570\uff1a<\/text>\n    <text x=\"0\" y=\"20\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u8f93\u5165\u7535\u538b\uff1a100-240V CA, 50\/60Hz<\/text>\n    <text x=\"0\" y=\"35\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u8f93\u51fa\u7535\u538b\uff1a24V CC \u00b11%<\/text>\n    <text x=\"0\" y=\"50\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u7eb9\u6ce2\u7cfb\u6570\uff1a&lt; 1%<\/text>\n    \n    <text x=\"300\" y=\"20\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u8f6c\u6362\u6548\u7387\uff1a85-90%<\/text>\n    <text x=\"300\" y=\"35\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u8d1f\u8f7d\u8c03\u6574\u7387\uff1a&lt; 0,5%<\/text>\n    <text x=\"300\" y=\"50\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u7ebf\u6027\u8c03\u6574\u7387\uff1a&lt; 0,3%<\/text>\n    \n    <text x=\"600\" y=\"20\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u4fdd\u62a4\u529f\u80fd\uff1a\u8fc7\u538b\u3001\u8fc7\u6d41\u3001\u8fc7\u6e29\u4fdd\u62a4<\/text>\n    <text x=\"600\" y=\"35\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u5de5\u4f5c\u6e29\u5ea6\uff1a-10\u00b0C ~ +60\u00b0C<\/text>\n    <text x=\"600\" y=\"50\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#666\">- \u5b89\u5168\u6807\u51c6\uff1aCE, UL, FCC\u8ba4\u8bc1<\/text>\n  <\/g>\n  \n  <!-- \u7bad\u5934\u6807\u8bb0\u5b9a\u4e49 -->\n  <defs>\n    <marker id=\"arrowhead\" markerwidth=\"10\" markerheight=\"7\" refx=\"9\" refy=\"3.5\" orient=\"auto\">\n      <polygon points=\"0 0, 10 3.5, 0 7\" fill=\"#666\"\/>\n    <\/marker>\n  <\/defs>\n<\/svg>\n\n\n\n<h3 class=\"wp-block-heading\">Proceso de conversi\u00f3n:<\/h3>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>Entrada de CA (100-240 V):<\/strong> La unidad se conecta a una fuente de alimentaci\u00f3n est\u00e1ndar.<\/li>\n\n\n\n<li><strong>Rectificaci\u00f3n:<\/strong> La corriente alterna (CA) se convierte en corriente continua no regulada mediante un puente rectificador.<\/li>\n\n\n\n<li><strong>Filtrado:<\/strong> Los condensadores suavizan la se\u00f1al rectificada para reducir el rizado.<\/li>\n\n\n\n<li><strong>Reglamento:<\/strong> Un regulador de tensi\u00f3n garantiza una salida estable de 24 V CC independientemente de la fluctuaci\u00f3n de la carga.<\/li>\n<\/ol>\n\n\n\n<p>Los PLC modernos emplean fuentes de alimentaci\u00f3n conmutadas en lugar de reguladores lineales. Son m\u00e1s compactas, eficientes y generan menos calor, requisitos clave para los sistemas cerrados y sin ventilador.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Compatibilidad con doble entrada<\/h3>\n\n\n\n<p>Otros tipos de PLC aceptan tanto entradas de CA como de CC y, por tanto, ofrecen m\u00e1s flexibilidad en las distintas disposiciones el\u00e9ctricas. En este caso, los circuitos internos est\u00e1n programados para autodetectar y ajustarse al tipo de entrada, por lo que el proceso de utilizaci\u00f3n es perfecto.<\/p>\n\n\n\n<p>Este dise\u00f1o ofrecer\u00e1 una sofisticada transici\u00f3n entre las soluciones basadas en CA y CC del pasado y las arquitecturas de control basadas en CC del futuro. Tambi\u00e9n significa que incluso en instalaciones en las que normalmente no se distribuyen 24 V CC se pueden instalar PLC sin que sea necesario incorporar fuentes de alimentaci\u00f3n externas independientes en la instalaci\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Selecci\u00f3n de la potencia adecuada<\/h2>\n\n\n\n<p>Seleccionar un PLC con la potencia nominal adecuada es fundamental para evitar ca\u00eddas de tensi\u00f3n, sobrecargas o bajo rendimiento. La carga total del sistema debe calcularse en funci\u00f3n del consumo de corriente tanto de los circuitos internos como de los dispositivos externos alimentados por el PLC.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Factores clave a tener en cuenta:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Carga total de E\/S:<\/strong> Suma de todos los dispositivos de entrada y salida conectados, incluidos rel\u00e9s, solenoides, sensores, etc.<\/li>\n\n\n\n<li><strong>Corriente de arranque:<\/strong> Los dispositivos como las electrov\u00e1lvulas o los motores pueden consumir una corriente m\u00e1s alta moment\u00e1neamente al arrancar.<\/li>\n\n\n\n<li><strong>Reserva de marcha:<\/strong> Incluye siempre un buffer - 20% es habitual - para acomodar futuras expansiones o fluctuaciones de potencia.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Ejemplo de tabla de presupuesto de energ\u00eda<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Tipo de dispositivo<\/td><td>Cantidad<\/td><td>Corriente por dispositivo (mA)<\/td><td>Corriente total (mA)<\/td><\/tr><tr><td>Sensores de proximidad<\/td><td>4<\/td><td>15<\/td><td>60<\/td><\/tr><tr><td>Indicadores luminosos<\/td><td>3<\/td><td>20<\/td><td>60<\/td><\/tr><tr><td>Salidas de rel\u00e9<\/td><td>6<\/td><td>40<\/td><td>240<\/td><\/tr><tr><td>Circuito l\u00f3gico PLC<\/td><td>1<\/td><td>150<\/td><td>150<\/td><\/tr><tr><td>Total<\/td><td><\/td><td><\/td><td>510<\/td><\/tr><tr><td>+20% Buffer<\/td><td><\/td><td><\/td><td>612 mA<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>En este ejemplo, un PLC con al menos <strong>0,7 A (700 mA)<\/strong> de la capacidad de alimentaci\u00f3n de 24 V CC disponible.<\/p>\n\n\n\n<p>Algunos PLC peque\u00f1os permiten aplicar alimentaci\u00f3n externa de 24 V por separado a los terminales de E\/S, aliviando la fuente de alimentaci\u00f3n interna. Conocer la arquitectura ayuda a evitar sobreespecificaciones o tensiones en los componentes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Soluci\u00f3n de problemas con la fuente de alimentaci\u00f3n<\/h2>\n\n\n\n<p>A pesar de su fiabilidad, los PLC peque\u00f1os pueden tener problemas relacionados con la alimentaci\u00f3n el\u00e9ctrica que pueden interrumpir los procesos de automatizaci\u00f3n. Identificar y resolver estos problemas con rapidez es esencial para minimizar el tiempo de inactividad.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">S\u00edntomas comunes:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>El LED de encendido no se enciende:<\/strong> Indica ausencia de tensi\u00f3n de alimentaci\u00f3n o fallo de la alimentaci\u00f3n interna<\/li>\n\n\n\n<li><strong>Reinicios inesperados:<\/strong> Puede deberse a una tensi\u00f3n de alimentaci\u00f3n intermitente<\/li>\n\n\n\n<li><strong>Fallos de entrada\/salida:<\/strong> Puede ocurrir si la tensi\u00f3n cae bajo carga<\/li>\n\n\n\n<li><strong>Errores de comunicaci\u00f3n:<\/strong> Una mala regulaci\u00f3n de la tensi\u00f3n puede afectar a los buses internos<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Lista de comprobaci\u00f3n para la resoluci\u00f3n de problemas:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Compruebe que la tensi\u00f3n de entrada est\u00e1 dentro del rango especificado (por ejemplo, 100-240 V CA).<\/li>\n\n\n\n<li>Mida la tensi\u00f3n de salida de CC en los terminales internos, si son accesibles.<\/li>\n\n\n\n<li>Inspeccione si hay conexiones de terminales sueltas o signos de corrosi\u00f3n.<\/li>\n\n\n\n<li>Confirme que la conexi\u00f3n a tierra es segura y adecuada<\/li>\n\n\n\n<li>Compruebe la temperatura ambiente: el sobrecalentamiento puede activar la desconexi\u00f3n de protecci\u00f3n.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Buenas pr\u00e1cticas de cableado:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Utilice calibres de cable adecuados para la potencia de entrada<\/li>\n\n\n\n<li>Conecte a tierra el PLC de acuerdo con las especificaciones del fabricante<\/li>\n\n\n\n<li>Evite el tendido en paralelo de l\u00edneas de alimentaci\u00f3n y de se\u00f1al<\/li>\n<\/ul>\n\n\n\n<p>Si se mantiene una alimentaci\u00f3n limpia y regulada y se siguen los procedimientos de instalaci\u00f3n adecuados, pueden evitarse la mayor\u00eda de los problemas de alimentaci\u00f3n. Consulte la documentaci\u00f3n del fabricante para obtener diagn\u00f3sticos detallados y procedimientos de sustituci\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Cu\u00e1ndo utilizar m\u00f3dulos de alimentaci\u00f3n externos<\/h2>\n\n\n\n<p>Aunque las fuentes de alimentaci\u00f3n integradas son ideales para PLC peque\u00f1os en situaciones de carga baja o media, determinadas aplicaciones exigen una mayor flexibilidad o capacidad: aqu\u00ed es donde entran en juego los m\u00f3dulos de alimentaci\u00f3n externos.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Cuando los m\u00f3dulos externos tienen sentido:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Alta <\/strong><strong>E\/S<\/strong><strong> Carga:<\/strong> Los sistemas con decenas de salidas pueden superar los l\u00edmites de la alimentaci\u00f3n interna.<\/li>\n\n\n\n<li><strong>Requisitos de redundancia:<\/strong> Las operaciones de misi\u00f3n cr\u00edtica suelen utilizar entradas de alimentaci\u00f3n dobles o fuentes intercambiables en caliente.<\/li>\n\n\n\n<li><strong>Arquitecturas PLC modulares:<\/strong> Suelen separar las unidades de CPU, E\/S y alimentaci\u00f3n para aumentar la escalabilidad.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Ventajas de las fuentes de alimentaci\u00f3n externas:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Escalable: Elija m\u00f3dulos de potencia que se ajusten exactamente a las necesidades del sistema<\/li>\n\n\n\n<li>Aislado: Reduce el ruido y las interferencias en circuitos sensibles<\/li>\n\n\n\n<li>Mantenimiento: F\u00e1cil de sustituir o actualizar sin afectar al n\u00facleo del PLC.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Contrapartidas:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Aumenta la complejidad y el tama\u00f1o del panel<\/li>\n\n\n\n<li>Requiere planificaci\u00f3n y cableado adicionales<\/li>\n\n\n\n<li>Aumenta el coste total del sistema<\/li>\n<\/ul>\n\n\n\n<p>Si su aplicaci\u00f3n es compleja, requiere ampliaciones frecuentes o funciona en condiciones adversas, puede que merezca la pena explorar opciones de PLC modulares con capacidad de alimentaci\u00f3n externa.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Componentes de automatizaci\u00f3n de confianza de OMCH<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img alt=\"\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/D-30-1.webp\" class=\"wp-image-7574\" style=\"object-fit:cover;width:512px;height:512px\" srcset=\"https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/D-30-1.webp 600w, https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/D-30-1-300x300.webp 300w, https:\/\/www.omch.com\/wp-content\/uploads\/2025\/08\/D-30-1-150x150.webp 150w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure>\n\n\n\n<p>Con m\u00e1s de 30 a\u00f1os de experiencia en el sector, OMCH es un proveedor fiable de componentes de automatizaci\u00f3n desde 1986. Desde fuentes de alimentaci\u00f3n hasta sensores y elementos neum\u00e1ticos, nuestra gama de productos es compatible con una amplia variedad de sistemas basados en PLC.<\/p>\n\n\n\n<p>Nuestros componentes est\u00e1n respaldados por las certificaciones ISO 9001, CE, CCC y RoHS, lo que garantiza su conformidad y fiabilidad en todos los mercados mundiales. Para proyectos que requieren dise\u00f1os personalizados o soluciones OEM, OMCH ofrece una fabricaci\u00f3n flexible para satisfacer necesidades t\u00e9cnicas y de integraci\u00f3n espec\u00edficas.<\/p>\n\n\n\n<p>Tanto si busca m\u00f3dulos de potencia compactos como si desea planificar un sistema de control escalable, OMCH le ofrece una calidad constante y una asistencia fiable.<\/p>\n\n\n\n<p>M\u00e1s informaci\u00f3n en <strong><a href=\"https:\/\/www.omch.com\/es\/\">omch.com<\/a><\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusi\u00f3n<\/h2>\n\n\n\n<p>El prop\u00f3sito de utilizar 24 V CC est\u00e1 a caballo entre la seguridad, la estandarizaci\u00f3n y la simplicidad del sistema. Siempre es importante utilizar fuentes de alimentaci\u00f3n integradas y una optimizaci\u00f3n eficaz de la capacidad para que estos controladores compactos puedan seguir siendo el trampol\u00edn hacia una automatizaci\u00f3n eficiente y fiable.<\/p>\n\n\n\n<p>Para el ingeniero o integrador, el conocimiento de la arquitectura de potencia de un PLC es m\u00e1s que una especificaci\u00f3n; es fundamental para la estabilidad, escalabilidad y seguridad del sistema. Y cuando todas las piezas cuentan, merece la pena recurrir a fabricantes de confianza, como OMCH.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Qu\u00e9 define a un PLC peque\u00f1o Los microprocesadores o PLC de tipo ladrillo son peque\u00f1os controladores de automatizaci\u00f3n adecuados para ejecutar aplicaciones de control b\u00e1sicas. Su naturaleza simplista, su bajo precio y la comodidad de instalarlos en espacios potencialmente limitados los hacen muy populares. Los PLC peque\u00f1os se suministran normalmente con configuraciones de entrada\/salida (E\/S) predeterminadas y componentes incorporados, como [...]<\/p>","protected":false},"author":4,"featured_media":7659,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"Why the Power Supply in a Small PLC Is Often 24V DC","_seopress_titles_desc":"Discover why the power supply in a small PLC is often 24V DC. Our blog explores its benefits and applications in automation systems.","_seopress_robots_index":"","footnotes":""},"categories":[44],"tags":[],"class_list":["post-7652","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-supply"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/posts\/7652","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/comments?post=7652"}],"version-history":[{"count":3,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/posts\/7652\/revisions"}],"predecessor-version":[{"id":8786,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/posts\/7652\/revisions\/8786"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/media\/7659"}],"wp:attachment":[{"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/media?parent=7652"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/categories?post=7652"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/tags?post=7652"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}