{"id":4789,"date":"2025-05-14T03:20:54","date_gmt":"2025-05-14T03:20:54","guid":{"rendered":"https:\/\/www.omch.com\/?p=4789"},"modified":"2026-07-16T08:27:11","modified_gmt":"2026-07-16T08:27:11","slug":"what-is-a-switching-power-supply","status":"publish","type":"post","link":"https:\/\/www.omch.com\/es\/what-is-a-switching-power-supply\/","title":{"rendered":"What Is a Switching Power Supply (SMPS)? How It Works, Types, and What to Look For"},"content":{"rendered":"<!DOCTYPE html>\n<html><head>\n  <meta charset=\"utf-8\">\n  <meta name=\"viewport\" content=\"width=device-width, initial-scale=1\">\n  <title>What Is a Switching Power Supply (SMPS)? How It Works, Types, and What to Look For<\/title>\n<\/head>\n<body>\n<!-- \u2193\u2193\u2193 The deployable fragment begins here. \u2193\u2193\u2193 -->\n<div class=\"bd-post\">\n  <style>\n    @import url('https:\/\/fonts.googleapis.com\/css2?family=Manrope:wght@400;600;700&family=Roboto:wght@600;700&display=swap');\n\n    .bd-post {\n      --prose-width: 720px;\n      --gap-attach: 16px;\n      --gap-normal: 32px;\n      --gap-section: 48px;\n      --pad-compact: 16px;\n      --pad-standard: 24px;\n\n      \/* Palette tokens \u2014 all solid, verbatim from design-plan.md *\/\n      --body-bg: #FFFFFF;\n      --text-primary: #333333;\n      --text-secondary: #6E6E6E;\n      --heading-ink: #000000;\n      --accent: #479DE2;\n      --accent-text: #0D3972;\n      --accent-hot: #FD9649;\n      --inverse-bg: #1E1E1E;\n      --inverse-text: #FFFFFF;\n      --inverse-text-2: #B0B0B0;\n      --inverse-accent: #479DE2;\n      --card-fill: #F4F8FC;\n      --card-border: #C8C8C8;\n      --card-text: #333333;\n      --card-text-2: #6E6E6E;\n      --panel-fill: #FAFAFA;\n      --panel-text: #333333;\n      --panel-text-2: #6E6E6E;\n      --btn-white: #FFFFFF;\n      --btn-ink: #0D3972;\n\n      font-family: \"Manrope\", sans-serif;\n      font-size: 16px;\n      font-weight: 400;\n      line-height: 1.6;\n      color: var(--text-primary);\n      background: var(--body-bg);\n      padding: 40px;\n      max-width: 100%;\n      box-sizing: border-box;\n    }\n    .bd-post a { overflow-wrap: anywhere; word-break: break-word; }\n    .bd-post p a, .bd-post li a, .bd-post blockquote a, .bd-post td a { color: var(--accent); text-decoration: underline; }\n    .bd-post p, .bd-post li { overflow-wrap: break-word; }\n    .bd-post .bd-post-article { max-width: var(--prose-width); margin: 0 auto; }\n\n    \/* Prose spacing \u2014 fixed standard *\/\n    .bd-post p  { margin: 0 0 1em; }\n    .bd-post h1 { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 34px; line-height: 1.2; color: var(--heading-ink); margin: 0 0 16px; }\n    .bd-post h2 { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 34px; line-height: 1.2; color: var(--heading-ink); margin: 48px 0 16px; }\n    .bd-post h3 { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 24px; line-height: 1.25; color: var(--heading-ink); margin: 32px 0 12px; }\n    .bd-post ul, .bd-post ol { margin: 0 0 1em; padding-left: 1.5em; }\n    .bd-post li { margin-bottom: 0.5em; }\n    .bd-post strong { font-weight: 700; }\n    .bd-post blockquote { border-left: 3px solid var(--accent); background: transparent; padding: 12px 20px; margin: 24px 0; font-style: italic; color: var(--text-secondary); }\n    .bd-post code { background: var(--panel-fill); font-family: \"SF Mono\", Menlo, monospace; font-size: 0.9em; padding: 2px 6px; border-radius: 4px; }\n    .bd-post hr { height: 1px; background: var(--card-border); border: none; margin: 32px 0; }\n\n    .bd-post .table-wrapper { overflow-x: auto; margin: 0 0 1em; }\n    .bd-post table { width: 100%; border-collapse: collapse; font-size: 14px; }\n    .bd-post th { background: var(--panel-fill); font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 14px; color: var(--heading-ink); padding: 10px 12px; text-align: left; border: 1px solid var(--card-border); }\n    .bd-post td { padding: 10px 12px; border: 1px solid var(--card-border); color: var(--text-primary); }\n\n    \/* Selector hygiene *\/\n    .bd-post [class*=\"bp-\"] { box-sizing: border-box; }\n    .bd-post .bd-post-article > .bp-1-stat-compare,\n    .bd-post .bd-post-article > .bp-2-signal-flow,\n    .bd-post .bd-post-article > .bp-3-checklist,\n    .bd-post .bd-post-article > .bp-cta-end { margin: var(--gap-normal) 0; }\n\n    \/* BP-1: Efficiency Stat Comparison *\/\n    .bp-1-stat-compare { background: var(--card-fill); border: 1px solid var(--card-border); border-radius: 8px; padding: var(--pad-standard); display: grid; grid-template-columns: 1fr 1fr; align-items: center; }\n    .bp-1-col { text-align: center; padding: 8px 0; }\n    .bp-1-col:first-child { border-right: 1px solid var(--card-border); }\n    .bp-1-icon { display: block; margin: 0 auto 8px; color: var(--accent-text); }\n    .bp-1-num { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 48px; line-height: 1.1; }\n    .bp-1-num-smps { color: var(--accent-text); }\n    .bp-1-num-linear { color: var(--text-secondary); }\n    .bp-1-label { font-family: \"Manrope\", sans-serif; font-weight: 600; font-size: 14px; text-transform: uppercase; letter-spacing: 0.5px; color: var(--text-secondary); margin-top: 4px; }\n    .bp-1-sub { font-family: \"Manrope\", sans-serif; font-weight: 400; font-size: 13px; color: var(--text-secondary); margin-top: 6px; line-height: 1.4; }\n\n    \/* BP-2: 5-Stage Signal Flow *\/\n    .bp-2-signal-flow { background: var(--card-fill); border: 1px solid var(--card-border); border-radius: 8px; padding: var(--pad-standard); }\n    .bp-2-flow { display: flex; align-items: flex-start; }\n    .bp-2-stage { flex: 1; text-align: center; }\n    .bp-2-arrow { flex: 0 0 auto; width: 32px; height: 32px; display: flex; align-items: center; justify-content: center; color: var(--card-border); }\n    .bp-2-num { width: 32px; height: 32px; border-radius: 50%; background: var(--accent-text); color: var(--btn-white); font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 14px; display: inline-flex; align-items: center; justify-content: center; line-height: 1; }\n    .bp-2-title { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 14px; color: var(--heading-ink); margin-top: 8px; }\n    .bp-2-desc { font-family: \"Manrope\", sans-serif; font-weight: 400; font-size: 12px; color: var(--text-secondary); margin-top: 4px; line-height: 1.4; padding: 0 4px; }\n\n    \/* BP-3: Protection Checklist *\/\n    .bp-3-checklist { background: var(--card-fill); border: 1px solid var(--card-border); border-left: 3px solid var(--accent-text); border-radius: 0 8px 8px 0; padding: var(--pad-compact); }\n    .bp-3-row { display: flex; align-items: flex-start; gap: 10px; padding: 6px 0; }\n    .bp-3-check { flex-shrink: 0; color: var(--accent-text); margin-top: 2px; }\n    .bp-3-label { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 14px; color: var(--heading-ink); }\n    .bp-3-desc { font-family: \"Manrope\", sans-serif; font-weight: 400; font-size: 13px; color: var(--text-secondary); margin-top: 2px; line-height: 1.4; }\n    .bp-3-note { border-top: 1px solid var(--card-border); margin-top: 8px; padding-top: 8px; font-family: \"Manrope\", sans-serif; font-weight: 400; font-size: 12px; font-style: italic; color: var(--text-secondary); }\n\n    \/* BP-cta-end: End CTA Panel *\/\n    .bp-cta-end { background: var(--inverse-bg); border-radius: 8px; padding: var(--pad-standard); text-align: center; }\n    .bp-cta-end-icon { display: block; margin: 0 auto 12px; color: var(--inverse-accent); }\n    .bp-cta-end-title { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 22px; color: var(--inverse-text); margin-bottom: 8px; }\n    .bp-cta-end-sub { font-family: \"Manrope\", sans-serif; font-weight: 400; font-size: 14px; color: var(--inverse-text-2); margin-bottom: 20px; max-width: 480px; margin-left: auto; margin-right: auto; line-height: 1.5; }\n    .bp-cta-end-btn { display: inline-flex; align-items: center; gap: 8px; font-family: \"Roboto\", sans-serif; font-weight: 600; font-size: 15px; padding: 12px 28px; border-radius: 6px; border: none; cursor: pointer; text-decoration: none; background: var(--accent-hot); color: var(--btn-ink); }\n    .bp-cta-end-btn:hover { background: var(--btn-white); color: var(--btn-ink); }\n    .bp-cta-end-btn svg { flex-shrink: 0; }\n\n    \/* Motion \u2014 sanctioned, gated *\/\n    @media (prefers-reduced-motion: no-preference) {\n      @supports (animation-timeline: view()) {\n        .bd-post .bd-reveal { animation: bd-fade-in linear both; animation-timeline: view(); animation-range: entry 0% entry 35%; }\n        @keyframes bd-fade-in { from { opacity: 0; } to { opacity: 1; } }\n      }\n      .bd-post h2 { transition: color .2s ease-out, transform .2s ease-out; transform-origin: left; }\n      .bd-post h2:hover { color: var(--accent-text); transform: scale(1.02); }\n      .bd-post p a, .bd-post li a { transition: color .2s ease-out, text-decoration-color .2s ease-out; }\n      .bd-post p a:hover, .bd-post li a:hover { color: var(--accent-hot); }\n      .bd-post .bp-1-stat-compare { transition: transform .2s ease-out, box-shadow .2s ease-out; }\n      .bd-post .bp-1-stat-compare:hover { transform: translateY(-2px); box-shadow: 0 6px 18px rgba(0,0,0,0.08); }\n      .bd-post .bp-1-col { transition: color .2s ease-out; }\n      .bd-post .bp-1-col:hover .bp-1-num-smps,\n      .bd-post .bp-1-col:hover .bp-1-icon { color: var(--accent-hot); }\n      .bd-post .bp-2-stage { transition: color .2s ease-out; }\n      .bd-post .bp-2-stage:hover .bp-2-num { box-shadow: 0 0 0 3px var(--accent-hot); }\n      .bd-post .bp-2-stage:hover .bp-2-title { color: var(--accent-text); }\n      .bd-post .bp-3-row { transition: color .2s ease-out; }\n      .bd-post .bp-3-row:hover .bp-3-check { color: var(--accent-hot); }\n      .bd-post .bp-cta-end-btn { transition: background .15s ease, color .15s ease, transform .15s ease; }\n      .bd-post .bp-cta-end-btn:hover { transform: translateY(-1px); }\n    }\n\n    @media (max-width: 768px) {\n      .bd-post { padding: 16px; }\n      .bd-post h1 { font-size: 26px; }\n      .bd-post h2 { font-size: 26px; margin-top: 32px; }\n      .bd-post h3 { font-size: 20px; margin-top: 24px; }\n      .bd-post .bp-1-stat-compare { grid-template-columns: 1fr; }\n      .bd-post .bp-1-col:first-child { border-right: none; border-bottom: 1px solid var(--card-border); padding-bottom: 12px; }\n      .bd-post .bp-1-col:last-child { padding-top: 12px; }\n      .bd-post .bp-2-flow { flex-direction: column; }\n      .bd-post .bp-2-stage { text-align: left; display: flex; align-items: flex-start; gap: 12px; }\n      .bd-post .bp-2-num { flex-shrink: 0; }\n      .bd-post .bp-2-arrow { width: 100%; height: 20px; display: flex; align-items: center; justify-content: center; }\n      .bd-post .bp-2-arrow svg { transform: rotate(90deg); }\n      .bd-post .bp-2-title { margin-top: 0; }\n    }\n  <\/style>\n  <article class=\"bd-post-article\">\n    <h1><\/h1>\n\n    <h2>What Is a Switching Power Supply (SMPS)?<\/h2>\n<img decoding=\"async\" src=\"https:\/\/www.omch.com\/wp-content\/uploads\/2025\/05\/Gemini_Generated_Image_45wkkt45wkkt45wk.webp\" alt=\"\u63cf\u8ff0\u6587\u5b57\" class=\"bd-post-image\" loading=\"lazy\">\n\n    <p>A switching power supply \u2014 also called a switched-mode power supply, switch-mode power supply, or simply SMPS \u2014 is an electronic device that converts electrical power from one form to another using a high-speed switching regulator. Unlike older linear power supplies that burn off excess voltage as waste heat, an SMPS rapidly switches a transistor on and off thousands of times per second, transferring energy in precise, efficient pulses.<\/p>\n\n    <p>The abbreviation SMPS stands for Switched-Mode Power Supply. You will also see it referred to as a switching power supply or switch-mode power supply. All three terms point to the same technology. What matters is not the name but the core idea: by operating at high frequencies (typically 20 kilohertz to several megahertz), an SMPS achieves efficiency levels of 80% to over 95%. A linear power supply, by comparison, typically manages only 40% to 60%.<\/p>\n\n    <p>Why should you care? Because SMPS technology is the reason your phone charger fits in your palm instead of weighing as much as a brick. It is the reason industrial control cabinets can power dozens of devices from compact DIN-rail units rather than room-sized transformer banks. Every time you plug in a laptop, power up a factory PLC, or charge a cordless tool, you are relying on a switching power supply to deliver stable, efficient DC power from an AC wall outlet.<\/p>\n\n    <h2>SMPS vs. Linear Power Supply \u2014 Why the Difference Matters<\/h2>\n\n    <p>To really understand what an SMPS is, you need to understand what it replaced. Linear power supplies and switching power supplies solve the same fundamental problem \u2014 converting one voltage to another \u2014 but they do it in fundamentally opposite ways. A linear supply works like driving with the brakes partially engaged: the regulating transistor operates in its linear region, continuously dissipating the difference between input and output voltage as heat. An SMPS works like pulse modulation: the switching transistor is either fully on or fully off, and energy transfers only during precisely timed intervals.<\/p>\n\n    <h3>Efficiency \u2014 The Core Advantage<\/h3>\n\n    <p>Efficiency is not a minor detail. It is the entire reason SMPS technology exists. A linear power supply delivering 100 watts to a load might draw 170 to 250 watts from the wall, turning 70 to 150 watts directly into heat. An equivalent SMPS delivering the same 100 watts draws only 105 to 125 watts, wasting just 5 to 25 watts as heat.<\/p>\n\n    <p>The physics behind this gap is straightforward. In a linear regulator, the pass transistor operates in its active region, where voltage across the transistor multiplied by current through it equals continuous power dissipation. Think of it as holding a door halfway open against a strong wind \u2014 you are fighting the wind the entire time. In an SMPS, the switching transistor (typically a MOSFET) toggles between two states: fully on, where its resistance drops to milliohms and voltage across it is near zero, and fully off, where current is zero. In both states, power dissipation (voltage times current) is close to zero. The only losses occur during the brief transition between states, which lasts tens of nanoseconds.<\/p>\n\n    <!-- BP-1: Efficiency Stat Comparison -->\n    <div class=\"bp-1-stat-compare bd-reveal\">\n      <div class=\"bp-1-col\">\n        <svg class=\"bp-1-icon\" width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><polygon points=\"13 2 3 14 12 14 11 22 21 10 12 10 13 2\"\/><\/svg>\n        <div class=\"bp-1-num bp-1-num-smps\">80\u201395%<\/div>\n        <div class=\"bp-1-label\">SMPS Efficiency<\/div>\n        <div class=\"bp-1-sub\">5\u201325W wasted at 100W load<\/div>\n      <\/div>\n      <div class=\"bp-1-col\">\n        <svg class=\"bp-1-icon\" width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M14 14.76V3.5a2.5 2.5 0 0 0-5 0v11.26a4.5 4.5 0 1 0 5 0z\"\/><\/svg>\n        <div class=\"bp-1-num bp-1-num-linear\">40\u201360%<\/div>\n        <div class=\"bp-1-label\">Linear Efficiency<\/div>\n        <div class=\"bp-1-sub\">70\u2013150W wasted at 100W load<\/div>\n      <\/div>\n    <\/div>\n\n    <h3>Size and Weight \u2014 Why Your Charger Isn&#8217;t a Brick<\/h3>\n\n    <p>Open up a 100-watt linear power supply and you will find a transformer the size of a small shoebox, built around a heavy iron core. Open a 100-watt SMPS and the transformer fits in your palm, built around a lightweight ferrite core. The difference comes down to frequency.<\/p>\n\n    <p>Transformers transfer energy through a magnetic core, and the amount of energy a core can handle per cycle is fixed by its physical size. At 50 or 60 hertz (the frequency of mains electricity), a 100-watt transformer needs a substantial iron core. At 100 kilohertz (a typical SMPS switching frequency), the same core size could handle roughly 2,000 times more power. In practice, SMPS designers trade most of that headroom for dramatic size reduction. A 100-watt linear power supply might weigh 2 to 3 kilograms; an equivalent SMPS weighs 300 to 500 grams.<\/p>\n\n    <h3>Output Noise and Ripple \u2014 The Tradeoff<\/h3>\n\n    <p>If SMPS technology is so superior, why do linear power supplies still exist? The answer is noise. High-frequency switching inevitably produces voltage ripple on the output \u2014 typically 50 to 150 millivolts peak-to-peak in a standard SMPS \u2014 plus electromagnetic interference (EMI) that can couple into nearby sensitive circuits. A well-designed linear power supply produces ripple below 1 millivolt.<\/p>\n\n    <p>For digital circuits, microcontrollers, relays, and most industrial sensors, 50 to 150 millivolts of ripple is perfectly acceptable. But for precision analog measurements, high-end audio equipment, or sensitive medical instruments, that noise can corrupt readings or introduce audible artifacts. In those applications, either a linear supply or a specially designed low-noise SMPS (which can achieve below 10 millivolts of ripple at higher cost) becomes necessary.<\/p>\n\n    <h3>Complexity and Cost \u2014 More Parts, Better Value<\/h3>\n\n    <p>An SMPS contains more components than a linear supply: a PWM controller IC, a switching MOSFET, a high-frequency transformer, optocoupler feedback, and output filtering. A linear supply needs only a transformer, rectifier, filter capacitor, and regulator. But component count is not the same as cost. The linear supply&#8217;s cost is dominated by copper and iron \u2014 the bulky mains-frequency transformer and large heatsink. The SMPS&#8217;s cost is dominated by semiconductors, which get cheaper every year with manufacturing scale. Below roughly 50 watts, SMPS units are almost always cheaper to manufacture than equivalent linear supplies. Above 500 watts, linear supplies can still be cost-competitive on a per-unit basis, but their weight and efficiency penalties usually rule them out for anything that needs to be shipped or operated continuously.<\/p>\n\n    <h3>When to Choose Which \u2014 A Practical Guide<\/h3>\n\n    <p>After absorbing the four dimensions above, here is a straightforward decision framework:<\/p>\n\n    <ul>\n      <li><strong>Is your application precision analog, medical, or high-end audio?<\/strong> \u2192 Consider a linear supply or a purpose-built ultra-low-noise SMPS.<\/li>\n      <li><strong>Is power above 500 watts and physical size truly irrelevant?<\/strong> \u2192 A linear supply might work, but weigh the shipping and cooling costs before deciding.<\/li>\n      <li><strong>Everything else?<\/strong> \u2192 An SMPS is almost certainly the right answer. This includes consumer electronics, industrial control cabinets, LED lighting, telecom equipment, battery charging, and the vast majority of modern electronic devices.<\/li>\n    <\/ul>\n\n    <div class=\"table-wrapper\">\n      <table>\n        <thead><tr><th>Aplicaci\u00f3n<\/th><th>Recommended Type<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>Consumer electronics (chargers, adapters)<\/td><td>SMPS<\/td><\/tr>\n          <tr><td>Industrial control (PLC, sensors, relays)<\/td><td>SMPS \u2014 DIN-rail<\/td><\/tr>\n          <tr><td>Laboratory precision power supply<\/td><td>Linear or ultra-low-noise SMPS<\/td><\/tr>\n          <tr><td>LED lighting driver<\/td><td>SMPS \u2014 constant current<\/td><\/tr>\n          <tr><td>High-end audio amplifier<\/td><td>Linear or resonant SMPS<\/td><\/tr>\n          <tr><td>CNC motor drive (high power)<\/td><td>Unregulated linear or industrial SMPS with surge capacity<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <h2>How Does a Switching Power Supply Work?<\/h2>\n\n    <p>Every SMPS, regardless of its specific topology, follows the same five-stage signal path. Understanding this chain shows how a compact electronic device takes unstable AC wall power and delivers steady DC to sensitive equipment. Here is the complete journey from wall outlet to regulated output.<\/p>\n\n    <h3>Stage 1 \u2014 Input Rectification and Filtering<\/h3>\n\n    <p>The first job is turning alternating current into direct current. A bridge rectifier \u2014 an arrangement of four diodes \u2014 flips the negative half of the AC waveform positive, producing a series of unidirectional pulses. A large electrolytic capacitor then smooths these pulses into a rough DC voltage. For a 220-volt AC input, this stage produces approximately 311 volts DC, which is the peak voltage of the sine wave (220 \u00d7 \u221a2). In modern SMPS designs, an active power factor correction (PFC) stage often sits between the rectifier and the main converter, shaping the input current to match the voltage waveform and improving efficiency at the grid level.<\/p>\n\n    <h3>Stage 2 \u2014 High-Frequency Switching<\/h3>\n\n    <p>This is the stage that gives the switching power supply its name. A power MOSFET, driven by a PWM (pulse-width modulation) controller, chops the stable high-voltage DC into a train of high-frequency pulses. In industrial supplies, the switching frequency typically runs at 50 to 200 kilohertz. Compact adapters using gallium-nitride (GaN) transistors can push past 1 megahertz.<\/p>\n\n    <p>The key variable is the duty cycle: the percentage of each switching period that the MOSFET spends in the &#8220;on&#8221; state. If the output voltage needs to increase, the controller widens the pulses (higher duty cycle). If it needs to decrease, the controller narrows them. This pulse-width modulation is how the SMPS regulates its output without wasting energy. The MOSFET itself is either fully conducting (near-zero voltage drop) or fully blocking (zero current), so it dissipates almost no power in either state.<\/p>\n\n    <h3>Stage 3 \u2014 High-Frequency Transformation<\/h3>\n\n    <p>The high-frequency pulse train now enters a small ferrite-core transformer. Two things happen here simultaneously. First, the transformer steps the voltage up or down according to its turns ratio. A 10:1 winding ratio converts 310-volt pulses to 31-volt pulses, for example. Second, the transformer provides galvanic isolation: the input side (&#8220;hot&#8221; ground, referenced to mains) and the output side (&#8220;cold&#8221; ground, referenced to your equipment) are electrically separated, typically with an isolation rating of 1,500 to 3,000 volts AC. This isolation is what makes an SMPS safe to touch on the output side even when plugged into mains power.<\/p>\n\n    <p>The ferrite core is what makes the transformer so small. At 50 hertz, a transformer core must physically store energy for 10 milliseconds per half-cycle, requiring substantial magnetic material. At 100 kilohertz, each energy-transfer cycle lasts only 5 microseconds. A fraction of the material can handle the same power.<\/p>\n\n    <h3>Stage 4 \u2014 Output Rectification and Filtering<\/h3>\n\n    <p>The transformer&#8217;s output is high-frequency AC, not yet usable DC. A second rectification stage converts it back. Unlike the input rectifier, which can use ordinary silicon diodes, this stage requires Schottky diodes or fast-recovery diodes \u2014 components specifically designed to switch at high speed without wasting energy during the transition. A standard silicon diode trying to rectify 100-kilohertz pulses would spend too much time in its recovery phase, generating significant heat.<\/p>\n\n    <p>After rectification, an LC filter (an inductor and capacitor combination) smooths the output into clean DC. The inductor resists rapid changes in current, while the capacitor absorbs voltage fluctuations. Together they reduce the switching-frequency ripple to a level acceptable for the target application.<\/p>\n\n    <h3>Stage 5 \u2014 Feedback and Regulation Loop<\/h3>\n\n    <p>The four stages above would produce a raw DC output that drifts with load changes and input voltage variations. The feedback loop closes the system and makes regulation possible.<\/p>\n\n    <p>A precision voltage reference (commonly a TL431 adjustable shunt regulator set to 2.5 volts) provides a stable comparison point. A resistive divider samples the output voltage and feeds it to an error amplifier, which compares the sample against the reference and generates a correction signal. This signal crosses the isolation boundary through an optocoupler \u2014 a device that transmits information via light, maintaining the safety barrier between output and input sides. On the primary side, the PWM controller reads the correction signal and adjusts the duty cycle accordingly. The entire loop operates continuously, typically at a bandwidth of one-fifth to one-tenth of the switching frequency, ensuring the output stays locked to its target voltage regardless of load changes.<\/p>\n\n    <!-- BP-2: 5-Stage Signal Flow -->\n    <div class=\"bp-2-signal-flow bd-reveal\">\n      <div class=\"bp-2-flow\">\n        <div class=\"bp-2-stage\">\n          <div class=\"bp-2-num\">1<\/div>\n          <div class=\"bp-2-title\">Input Rectification<\/div>\n          <div class=\"bp-2-desc\">AC to rough DC via bridge rectifier + capacitor<\/div>\n        <\/div>\n        <div class=\"bp-2-arrow\"><svg width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/div>\n        <div class=\"bp-2-stage\">\n          <div class=\"bp-2-num\">2<\/div>\n          <div class=\"bp-2-title\">High-Frequency Switching<\/div>\n          <div class=\"bp-2-desc\">MOSFET chops DC at 50\u2013200kHz<\/div>\n        <\/div>\n        <div class=\"bp-2-arrow\"><svg width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/div>\n        <div class=\"bp-2-stage\">\n          <div class=\"bp-2-num\">3<\/div>\n          <div class=\"bp-2-title\">Transformation<\/div>\n          <div class=\"bp-2-desc\">Ferrite core steps voltage + isolates<\/div>\n        <\/div>\n        <div class=\"bp-2-arrow\"><svg width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/div>\n        <div class=\"bp-2-stage\">\n          <div class=\"bp-2-num\">4<\/div>\n          <div class=\"bp-2-title\">Output Filtering<\/div>\n          <div class=\"bp-2-desc\">Schottky diodes + LC filter smooth output<\/div>\n        <\/div>\n        <div class=\"bp-2-arrow\"><svg width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/div>\n        <div class=\"bp-2-stage\">\n          <div class=\"bp-2-num\">5<\/div>\n          <div class=\"bp-2-title\">Feedback Regulation<\/div>\n          <div class=\"bp-2-desc\">Optocoupler + PWM lock the voltage<\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <h2>Common Types of Switching Power Supplies<\/h2>\n\n    <p>Not all switching power supplies are built the same way. The topology \u2014 the specific arrangement of switches, transformers, and energy-storage components \u2014 determines a supply&#8217;s power range, efficiency ceiling, cost, and suitability for different applications. The primary division is between non-isolated topologies, which convert DC to DC without a transformer, and isolated topologies, which use a transformer for both voltage conversion and safety isolation.<\/p>\n\n    <div class=\"table-wrapper\">\n      <table>\n        <thead><tr><th>Topolog\u00eda<\/th><th>Tipo<\/th><th>Rango de potencia<\/th><th>Aplicaci\u00f3n t\u00edpica<\/th><th>One-Sentence Description<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>Buck<\/td><td>Non-isolated step-down<\/td><td>Up to 100W<\/td><td>Board-level DC-DC, LED drivers<\/td><td>Simplest topology; output voltage always lower than input<\/td><\/tr>\n          <tr><td>Boost<\/td><td>Non-isolated step-up<\/td><td>Up to 100W<\/td><td>Battery-powered boost, backlight drivers<\/td><td>Output voltage always higher than input<\/td><\/tr>\n          <tr><td>Flyback<\/td><td>Isolated<\/td><td>Up to 150W<\/td><td>Phone chargers, small adapters, auxiliary supplies<\/td><td>Most common and economical isolated topology<\/td><\/tr>\n          <tr><td>Forward<\/td><td>Isolated<\/td><td>100\u2013350W<\/td><td>PLC power supplies, industrial control<\/td><td>Better efficiency and lower ripple than flyback<\/td><\/tr>\n          <tr><td>Half\/Full Bridge<\/td><td>Isolated<\/td><td>350W\u20135kW+<\/td><td>Server PSUs, industrial power, electroplating<\/td><td>The workhorse for high-power applications<\/td><\/tr>\n          <tr><td>LLC Resonant<\/td><td>Isolated<\/td><td>200W\u20133kW<\/td><td>High-efficiency adapters, LED display power<\/td><td>Ultra-high efficiency with inherently low EMI<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>For most industrial automation applications (powering PLCs, sensors, relays, and contactors from a control cabinet), the 24-volt DIN-rail power supply you encounter is most likely a forward or flyback design, rated somewhere between 30 and 480 watts.<\/p>\n\n    <h2>Where Are Switching Power Supplies Used?<\/h2>\n\n    <p>Switching power supplies are so deeply embedded in modern life that you interact with dozens of them every day without noticing. They power the obvious devices \u2014 phone chargers, laptop adapters, television sets, and desktop computer PSUs \u2014 but their footprint extends far beyond consumer electronics.<\/p>\n\n    <p>In industrial automation, SMPS units are the silent backbone of every control cabinet. A typical manufacturing line contains dozens of 24-volt DC DIN-rail power supplies, each feeding a network of programmable logic controllers (PLCs), photoelectric and proximity sensors, signal tower lights, relays, contactors, and human-machine interface (HMI) panels. These are not standalone devices operating in isolation. They form an interconnected ecosystem where every component depends on clean, stable power to function reliably. A single under-specified or failing power supply can bring an entire production line to a halt.<\/p>\n\n    <p>Telecommunications infrastructure runs on SMPS technology at an even larger scale. Cellular base stations, data center server racks, and fiber-optic network nodes all use high-efficiency switching supplies \u2014 often with N+1 redundancy \u2014 to convert grid power or battery backup into the tightly regulated DC voltages their equipment demands.<\/p>\n\n    <p>Specialized SMPS variants serve LED lighting (constant-current drivers for displays and streetlights), electric vehicle charging (onboard chargers and DC fast-charging stations), and medical equipment (supplies with reinforced isolation and ultra-low leakage current). Each of these domains imposes its own requirements for efficiency, safety isolation, and environmental tolerance \u2014 which is why understanding the basics of what to look for in a power supply becomes valuable even if you are not an electrical engineer.<\/p>\n\n    <h2>What to Look For When Sourcing a Switching Power Supply<\/h2>\n\n    <p>Knowing what an SMPS is and how it works is one thing. Knowing what separates a reliable unit from a problematic one is another \u2014 and it is the question that matters most when you are responsible for procurement, system integration, or maintenance. The four dimensions below cover the specifications that directly affect reliability, compatibility, and long-term cost, without requiring an engineering degree to evaluate.<\/p>\n\n    <h3>Input and Output Specifications \u2014 The Non-Negotiables<\/h3>\n\n    <p>Getting the electrical specifications right is the first gate. If these are wrong, nothing else matters. Start with input voltage: if your equipment will be deployed across multiple regions, specify a universal input range of 100 to 240 volts AC, which covers North American 120-volt and Asian\/European 230-volt grids without modification. For regions with unstable grid power, look for a wide input tolerance (some industrial supplies accept 85 to 264 volts AC) to ride through brownouts without shutting down.<\/p>\n\n    <p>On the output side, 24 volts DC is the dominant standard in industrial automation, specified by IEC 61131-2 for programmable controller equipment. Other common outputs include 5 volts (digital logic), 12 volts (automotive and security systems), and 48 volts (telecom and Power-over-Ethernet infrastructure). The power rating should include at least a 20% to 30% margin above your calculated maximum load. Running a power supply continuously at or near its rated limit accelerates component aging, particularly in the electrolytic capacitors, which are the most common failure point. A supply run at 80% load might last 100,000 hours; the same supply at 100% load could fail in half that time.<\/p>\n\n    <h3>Form Factor and Mounting \u2014 Where It Goes Determines What Fits<\/h3>\n\n    <p>The best electrical specifications in the world are useless if the power supply physically does not fit where you need to install it. Industrial control cabinets overwhelmingly use DIN-rail mounting: a standardized 35-millimeter metal rail (EN 60715) that allows supplies to snap on and off without tools. For standalone equipment or semi-outdoor installations, enclosed supplies with metal or plastic housings provide physical protection and basic dust resistance. Open-frame supplies, which have no enclosure, are designed for embedding inside equipment that already provides its own housing. They save space and cost but require the integrator to handle safety clearances and cooling.<\/p>\n\n    <h3>Protection Features \u2014 What Keeps It Alive When Things Go Wrong<\/h3>\n\n    <p>Protection features are the difference between a supply that fails gracefully and one that takes connected equipment down with it. Four protections are worth confirming before purchase:<\/p>\n\n    <p><strong>Overvoltage protection (OVP)<\/strong> shuts down the output if the regulation loop fails and voltage rises beyond a safe threshold (typically 120% to 140% of the nominal output). Without OVP, a single component failure could expose every downstream device to destructive voltage levels.<\/p>\n\n    <p><strong>Overcurrent and short-circuit protection (OCP\/SCP)<\/strong> limit current during overloads and shut down instantly on a dead short. Most industrial supplies use &#8220;hiccup mode&#8221; for short-circuit recovery: the supply periodically attempts to restart every one to two seconds, and when the short is cleared, normal operation resumes automatically. This beats the alternative \u2014 latch mode, where the supply stays locked off until someone manually power-cycles it \u2014 in remote or hard-to-access installations.<\/p>\n\n    <p><strong>Overtemperature protection (OTP)<\/strong> monitors internal temperature and reduces output power or shuts down before heat damages components. This is particularly important in sealed enclosures or high-ambient-temperature environments where convection cooling may be inadequate.<\/p>\n\n    <p>Not every supply on the market includes all four protections as standard. Check the datasheet. If a protection feature is not explicitly listed, assume it is not present.<\/p>\n\n    <!-- BP-3: Protection Checklist -->\n    <div class=\"bp-3-checklist bd-reveal\">\n      <div class=\"bp-3-row\">\n        <svg class=\"bp-3-check\" width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\/><polyline points=\"9 12 11 14 15 10\"\/><\/svg>\n        <div class=\"bp-3-content\">\n          <div class=\"bp-3-label\">Overvoltage Protection (OVP)<\/div>\n          <div class=\"bp-3-desc\">Shuts down at 120\u2013140% of nominal output \u2014 prevents downstream damage<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"bp-3-row\">\n        <svg class=\"bp-3-check\" width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\/><polyline points=\"9 12 11 14 15 10\"\/><\/svg>\n        <div class=\"bp-3-content\">\n          <div class=\"bp-3-label\">Overcurrent &amp; Short-Circuit (OCP\/SCP)<\/div>\n          <div class=\"bp-3-desc\">Hiccup mode auto-restarts every 1\u20132s \u2014 no manual reset needed<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"bp-3-row\">\n        <svg class=\"bp-3-check\" width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\/><polyline points=\"9 12 11 14 15 10\"\/><\/svg>\n        <div class=\"bp-3-content\">\n          <div class=\"bp-3-label\">Overtemperature Protection (OTP)<\/div>\n          <div class=\"bp-3-desc\">Reduces power or shuts down before heat damages internal components<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"bp-3-row\">\n        <svg class=\"bp-3-check\" width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\/><polyline points=\"9 12 11 14 15 10\"\/><\/svg>\n        <div class=\"bp-3-content\">\n          <div class=\"bp-3-label\">Input Undervoltage Protection<\/div>\n          <div class=\"bp-3-desc\">Safe shutdown when grid voltage drops below operating threshold<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"bp-3-note\">Check the datasheet \u2014 if a protection is not listed, assume it is not present.<\/div>\n    <\/div>\n\n    <h3>Certifications and Quality Indicators \u2014 Trust but Verify<\/h3>\n\n    <p>Certifications are the closest thing to an objective quality signal in a market where specifications on paper can look identical across wildly different products. The requirements vary by destination market:<\/p>\n\n    <p>For Europe, CE marking is the legal minimum \u2014 but it is important to understand what CE means in practice. CE is a manufacturer&#8217;s self-declaration of conformity, not an independent third-party test. Reputable manufacturers back their CE marking with test reports from accredited labs; less scrupulous ones do not. For power supplies, the relevant directives include the Low Voltage Directive (LVD) and the Electromagnetic Compatibility (EMC) Directive. RoHS and REACH compliance address environmental and chemical safety requirements.<\/p>\n\n    <p>For North America, UL certification carries more weight. Unlike CE, UL listing (to standards such as UL 508 for industrial control equipment or UL 62368-1 for audio\/video and IT equipment) involves independent testing and periodic factory inspections by a Nationally Recognized Testing Laboratory (NRTL). Products without UL certification face significant barriers to sale, insurance coverage, and electrical inspection approval in the United States and Canada.<\/p>\n\n    <p>For Middle Eastern and Southeast Asian markets, additional local certifications may apply \u2014 SASO and SABER for Saudi Arabia, SIRIM for Malaysia, SNI for Indonesia. Confirming these requirements before placing an order avoids customs clearance delays that can stretch for weeks.<\/p>\n\n    <p>Beyond certifications, two practical quality indicators are worth attention. Efficiency ratings such as 80 PLUS (for computer-grade power supplies) or the efficiency tier declared in the datasheet directly affect long-term operating cost. A supply that is 5% more efficient can pay back its price premium in electricity savings over a few years of continuous operation. MTBF (Mean Time Between Failures) figures, typically calculated per Telcordia SR-332 or MIL-HDBK-217F, provide a statistical reliability baseline. Quality industrial supplies commonly quote 200,000 to 500,000 hours at 25\u00b0C ambient, though these numbers assume proper cooling and loading conditions.<\/p>\n\n    <hr>\n\n    <p><em>For those sourcing industrial automation components, it is worth noting that a switching power supply rarely operates alone in a control cabinet. It sits alongside sensors, relays, contactors, PLCs, and circuit breakers, all of which need to be specified, sourced, and maintained. Working with suppliers that cover multiple categories can simplify procurement and reduce the overhead of managing relationships with a dozen different factories. OMCH, for example, carries switching power supplies from 15 to 480 watts alongside over 30 other automation component categories, including sensors, relays, and low-voltage distribution equipment. Their catalog is available at <a href=\"https:\/\/www.omch.com\/es\/switch-mode-power-supply\/\">omch.com\/switch-mode-power-supply<\/a>.<\/em><\/p>\n\n    <!-- BP-cta-end: End CTA Panel -->\n    <div class=\"bp-cta-end bd-reveal\">\n      <svg class=\"bp-cta-end-icon\" width=\"28\" height=\"28\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><rect x=\"2\" y=\"4\" width=\"20\" height=\"16\" rx=\"2\"\/><path d=\"M22 7l-10 7L2 7\"\/><\/svg>\n      <div class=\"bp-cta-end-title\">Source Industrial SMPS and Automation Components<\/div>\n      <div class=\"bp-cta-end-sub\">Compare DIN-rail, enclosed, and LED driver switching power supplies from 15W to 480W \u2014 plus sensors, relays, and distribution equipment from a single supplier.<\/div>\n      <a class=\"bp-cta-end-btn\" href=\"https:\/\/www.omch.com\/es\/contact\/\" target=\"_self\">\n        Browse Power Supplies\n        <svg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg>\n      <\/a>\n    <\/div>\n\n    <h2>References<\/h2>\n\n    <ol>\n      <li>Monolithic Power Systems. &#8220;Switching Power Supply: Uses Advantages and Working Principle.&#8221; <a href=\"https:\/\/www.monolithicpower.com\/en\/learning\/resources\/switching-power-supply\">https:\/\/www.monolithicpower.com\/en\/learning\/resources\/switching-power-supply<\/a><\/li>\n      <li>Electronics For You. &#8220;SMPS: Basics &amp; Working of Switched Mode Power Supply.&#8221; <a href=\"https:\/\/www.electronicsforu.com\/technology-trends\/learn-electronics\/smps-basics-switched-mode-power-supply\">https:\/\/www.electronicsforu.com\/technology-trends\/learn-electronics\/smps-basics-switched-mode-power-supply<\/a><\/li>\n      <li>Analog Devices. &#8220;AN-140: Basic Concepts of Linear Regulator and Switching Mode Power Supplies.&#8221; <a href=\"https:\/\/www.analog.com\/en\/resources\/app-notes\/an-140.html\">https:\/\/www.analog.com\/en\/resources\/app-notes\/an-140.html<\/a><\/li>\n      <li>GIC India. &#8220;What is Industrial SMPS? Types, Uses, and Benefits Explained.&#8221; <a href=\"https:\/\/www.gicindia.com\/what-is-industrial-smps\/\">https:\/\/www.gicindia.com\/what-is-industrial-smps\/<\/a><\/li>\n      <li>IEC 61131-2. &#8220;Programmable controllers \u2014 Part 2: Equipment requirements and tests.&#8221; International Electrotechnical Commission.<\/li>\n      <li>EN 60715. &#8220;Dimensions of low-voltage switchgear and controlgear \u2014 Standardized mounting on rails for mechanical support of electrical devices.&#8221; CENELEC.<\/li>\n      <li>OMCH. &#8220;Switch Mode Power Supply.&#8221; <a href=\"https:\/\/www.omch.com\/es\/switch-mode-power-supply\/\">https:\/\/www.omch.com\/switch-mode-power-supply\/<\/a><\/li>\n      <li>OMCH. &#8220;Homepage.&#8221; <a href=\"https:\/\/www.omch.com\/es\/\">https:\/\/www.omch.com\/<\/a><\/li>\n    <\/ol>\n\n  <\/article>\n<\/div>\n<!-- \u2191\u2191\u2191 Fragment ends here. \u2191\u2191\u2191 -->\n<\/body><\/html>\n\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>What Is a Switching Power Supply (SMPS)? How It Works, Types, and What to Look For What Is a Switching Power Supply (SMPS)? A switching power supply \u2014 also called a switched-mode power supply, switch-mode power supply, or simply SMPS \u2014 is an electronic device that converts electrical power from one form to another using [&hellip;]<\/p>","protected":false},"author":4,"featured_media":4798,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"What Is a Switching Power Supply (SMPS)? How It Works, Types, and What to Look For","_seopress_titles_desc":"Complete guide to Switching Power Supplies (SMPS). Learn how they work, compare efficiency with linear power supplies, and explore industrial types and selection criteria.","_seopress_robots_index":"","footnotes":""},"categories":[79],"tags":[],"class_list":["post-4789","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mmlblog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/posts\/4789","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/comments?post=4789"}],"version-history":[{"count":2,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/posts\/4789\/revisions"}],"predecessor-version":[{"id":12108,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/posts\/4789\/revisions\/12108"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/media\/4798"}],"wp:attachment":[{"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/media?parent=4789"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/categories?post=4789"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/tags?post=4789"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}