{"id":12233,"date":"2026-09-09T09:55:11","date_gmt":"2026-09-09T09:55:11","guid":{"rendered":"https:\/\/www.omch.com\/?p=12233"},"modified":"2026-09-09T09:55:12","modified_gmt":"2026-09-09T09:55:12","slug":"relay-coil-voltage","status":"publish","type":"post","link":"https:\/\/www.omch.com\/es\/relay-coil-voltage\/","title":{"rendered":"Explicaci\u00f3n del voltaje de la bobina del rel\u00e9: c\u00f3mo leerlo, elegirlo y adaptarlo"},"content":{"rendered":"<!DOCTYPE html>\n<html><head>\n  <meta charset=\"utf-8\">\n  <meta name=\"viewport\" content=\"width=device-width, initial-scale=1\">\n  <title>Explicaci\u00f3n del voltaje de la bobina de un rel\u00e9: qu\u00e9 significa el n\u00famero que aparece en la carcasa (y c\u00f3mo elegir el adecuado)<\/title>\n<\/head>\n<body>\n<!-- \u2193\u2193\u2193 The deployable fragment begins here. \u2193\u2193\u2193 -->\n<div class=\"bd-post\">\n  <style>\n    @import url('https:\/\/fonts.googleapis.com\/css2?family=Manrope:wght@400;600;700&family=Roboto:wght@600;700&display=swap');\n\n    .bd-post {\n      \/* Brand Standard Blog CSS Header \u2014 verbatim values (origin-design OMCH) *\/\n      font-family: \"Manrope\", sans-serif;\n      font-size: 16px;\n      font-weight: 400;\n      line-height: 1.6;\n      color: var(--text-primary);\n      background: var(--body-bg);\n      \/* palette (design-plan 2026-09-04) \u2014 solid hexes, single source *\/\n      --body-bg: #FFFFFF;\n      --heading-ink: #000000;\n      --text-primary: #333333;\n      --text-secondary: #6E6E6E;\n      --accent-text: #2A76B4;\n      --accent-hot: #FD9649;\n      --card-fill: #FAFAFA;\n      --card-border: #E0E0E0;\n      --inverse-bg: #1E1E1E;\n      --inverse-text: #FFFFFF;\n      --inverse-text-2: #B0B0B0;\n      --inverse-accent: #6FB3EA;\n      --btn-white: #FFFFFF;\n      --btn-ink: #333333;\n      \/* FIXED prose spacing standard \u2014 identical in every article: *\/\n      --prose-width: 760px;\n      --gap-normal: 32px;\n      --gap-section: 48px;\n      --pad-compact: 16px;\n      --pad-standard: 24px;\n      padding: 40px;\n      max-width: 100%;\n      box-sizing: border-box;\n    }\n    .bd-post a { overflow-wrap: anywhere; word-break: break-word; }\n    \/* ANCHOR PERMIT-LIST: visual props only via content forms below *\/\n    .bd-post p a, .bd-post li a, .bd-post blockquote a, .bd-post td a {\n      color: var(--accent-text);\n      text-decoration: underline;\n      text-underline-offset: 2px;\n    }\n    .bd-post p, .bd-post li { overflow-wrap: break-word; }\n    .bd-post .bd-post-article { max-width: var(--prose-width); margin: 0 auto; }\n\n    \/* PROSE SPACING \u2014 FIXED STANDARD. px margins; nothing inherited from host. *\/\n    .bd-post p { margin: 0 0 1em; }\n    .bd-post h2 { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 34px; line-height: 1.2; color: var(--heading-ink); margin: 48px 0 16px; }\n    .bd-post h3 { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 24px; line-height: 1.25; color: var(--heading-ink); margin: 32px 0 12px; }\n    .bd-post ul, .bd-post ol { margin: 0 0 1em; padding-left: 1.5em; }\n    .bd-post li { margin-bottom: 0.5em; }\n    .bd-post strong { font-weight: 700; }\n    .bd-post em { font-style: italic; }\n    .bd-post code { font-family: ui-monospace, SFMono-Regular, Menlo, monospace; font-size: 0.9em; background: var(--card-fill); border: 1px solid var(--card-border); border-radius: 4px; padding: 1px 6px; color: var(--text-primary); }\n\n    .bd-post [class*=\"bp-\"] { box-sizing: border-box; }\n    .bd-post [class*=\"rich-\"] { box-sizing: border-box; }\n    .bd-post .bd-post-article > .rich-multicol,\n    .bd-post .bd-post-article > .rich-stats,\n    .bd-post .bd-post-article > .bd-supply-map,\n    .bd-post .bd-post-article > .bp-cta-end { margin: var(--gap-normal) 0; }\n    .bd-post .bd-post-article > .bd-field-rule { margin: var(--gap-section) 0 var(--gap-normal); }\n\n    \/* Tables \u2014 global prose style (md tables + comparison tables share it) *\/\n    .bd-post .table-wrapper { overflow-x: auto; margin: 0 0 1em; }\n    .bd-post table.rich-table { width: 100%; border-collapse: collapse; font-size: 16px; line-height: 1.5; }\n    .bd-post .rich-table-cap { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 18px; color: var(--heading-ink); text-align: left; margin: 0 0 8px; }\n    .bd-post table.rich-table th { background: var(--card-fill); color: var(--heading-ink); font-weight: 700; text-align: left; padding: 12px 14px; border: 1px solid var(--card-border); border-bottom: 2px solid var(--accent-text); }\n    .bd-post table.rich-table td { padding: 12px 14px; border: 1px solid var(--card-border); color: var(--text-primary); vertical-align: top; }\n    .bd-post table.rich-table td strong { color: var(--heading-ink); }\n\n    \/* ===== RICH: \u00a71 \u6f84\u6e05\u5361 (low box: card-fill + border + accent left bar) ===== *\/\n    .bd-post .rich-multicol { background: var(--card-fill); border: 1px solid var(--card-border); border-left: 4px solid var(--accent-text); border-radius: 10px; padding: var(--pad-standard); display: grid; grid-template-columns: 1fr 1fr; gap: 24px; }\n    .bd-post .rich-multicol-h { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 17px; color: var(--heading-ink); margin: 0 0 8px; }\n    .bd-post .rich-multicol-ic { display: inline-flex; vertical-align: -0.2em; margin-right: 8px; color: var(--accent-text); }\n    .bd-post .rich-multicol-p { margin: 0; color: var(--text-primary); }\n\n    \/* ===== RICH: \u00a72 \u8bb0\u5fc6\u94a9\u5b50\u7b7e\u540d\u5757 Card-Stats ===== *\/\n    .bd-post .rich-stats { background: var(--card-fill); border: 1px solid var(--card-border); border-radius: 10px; padding: var(--pad-standard); }\n    .bd-post .rich-stats-title { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 17px; color: var(--heading-ink); margin: 0 0 12px; }\n    .bd-post .rich-stats-ic { display: inline-flex; vertical-align: -0.2em; margin-right: 8px; color: var(--accent-text); }\n    .bd-post .rich-stats-num { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 44px; line-height: 1.1; color: var(--accent-text); margin: 0 0 4px; }\n    .bd-post .rich-stats-sub { margin: 0; color: var(--text-secondary); }\n    .bd-post .rich-stats-cap { margin: 8px 0 0; color: var(--text-primary); }\n\n    \/* ===== BP-1: \u00a74 \u4f9b\u7535\u4e16\u754c\u5bf9\u7167\u5361 (medium card) ===== *\/\n    .bd-post .bd-supply-map { background: var(--card-fill); border: 1px solid var(--card-border); border-radius: 10px; padding: 8px var(--pad-standard); }\n    .bd-post .bd-supply-row { display: flex; align-items: flex-start; gap: 16px; padding: 14px 0; border-bottom: 1px solid var(--card-border); }\n    .bd-post .bd-supply-row:last-child { border-bottom: none; }\n    .bd-post .bd-supply-ic { color: var(--accent-text); display: inline-flex; flex: 0 0 auto; align-self: flex-start; }\n    .bd-post .bd-supply-mid { flex: 1.4; min-width: 0; }\n    .bd-post .bd-supply-chg { flex: 1; min-width: 0; margin: 0; color: var(--text-primary); }\n    .bd-post .bd-supply-who-name { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 16px; color: var(--heading-ink); margin: 0 0 2px; transition: color .2s ease-out; }\n    .bd-post .bd-supply-who-desc { margin: 0; color: var(--text-secondary); font-size: 14px; }\n    .bd-post .bd-supply-row:hover .bd-supply-who-name { color: var(--accent-text); }\n\n    \/* ===== BP-2: \u00a75 \u94c1\u5f8b\u5f15\u53e5 (L0 recipe a \u2014 pure typography) ===== *\/\n    .bd-post .bd-field-rule { border-left: 4px solid var(--accent-text); padding: 4px 0 4px 20px; }\n    .bd-post .bd-field-rule-label { display: block; font-size: 13px; font-weight: 600; letter-spacing: 0.08em; text-transform: uppercase; color: var(--accent-text); margin: 0 0 6px; }\n    .bd-post .bd-field-rule-quote { font-family: \"Manrope\", sans-serif; font-weight: 600; font-size: 22px; line-height: 1.35; color: var(--heading-ink); margin: 0; }\n\n    \/* ===== BP-cta-end (colors: cta-states(end)) ===== *\/\n    .bd-post .bp-cta-end { background: var(--inverse-bg); border-radius: 12px; padding: 28px 24px; }\n    .bd-post .bp-cta-end-inner { max-width: 560px; margin: 0 auto; text-align: center; }\n    .bd-post .bp-cta-end-title { font-family: \"Roboto\", sans-serif; font-weight: 700; font-size: 26px; line-height: 1.25; color: var(--inverse-text); margin: 0; }\n    .bd-post .bp-cta-end-ic { display: inline-flex; vertical-align: -0.2em; margin-right: 8px; color: var(--inverse-accent); }\n    .bd-post .bp-cta-end-sub { font-size: 16px; color: var(--inverse-text-2); margin: 8px 0 0; }\n    .bd-post .bp-cta-end-btn { display: inline-flex; align-items: center; gap: 8px; margin-top: 20px; font-family: \"Roboto\", sans-serif; font-weight: 600; font-size: 16px; line-height: 1; text-decoration: none; border-radius: 4px; padding: 13px 24px; background: var(--accent-hot); color: var(--btn-ink); transition: background .2s ease-out, color .2s ease-out, transform .2s ease-out; }\n    .bd-post .bp-cta-end-btn:hover { background: var(--btn-white); color: var(--btn-ink); }\n    .bd-post .bp-cta-end-arrow { display: inline-flex; transition: transform .2s ease-out; }\n    .bd-post .bp-cta-end-btn:hover .bp-cta-end-arrow { transform: translateX(2px); }\n\n    \/* ===== Sanctioned motion \u2014 CSS-only, gated ===== *\/\n    @media (prefers-reduced-motion: no-preference) {\n      @supports (animation-timeline: view()) {\n        .bd-post .bd-reveal { animation: bd-fade-in linear both; animation-timeline: view(); animation-range: entry 0% entry 35%; }\n        @keyframes bd-fade-in { from { opacity: 0; } to { opacity: 1; } }\n      }\n      .bd-post .bd-supply-map { transition: transform .2s ease-out, box-shadow .2s ease-out; }\n      .bd-post .bd-supply-map:hover { transform: translateY(-2px); box-shadow: 0 6px 18px rgba(0, 0, 0, 0.08); }\n      .bd-post .bp-cta-end { transition: transform .2s ease-out, box-shadow .2s ease-out; }\n      .bd-post .bp-cta-end:hover { transform: translateY(-2px); box-shadow: 0 8px 22px rgba(0, 0, 0, 0.14); }\n      .bd-post .bd-post-article a { transition: color .2s ease-out; }\n      .bd-post p a:hover, .bd-post li a:hover, .bd-post blockquote a:hover, .bd-post td a:hover { color: var(--heading-ink); }\n    }\n\n    @media (max-width: 767px) {\n      .bd-post { padding: 16px; }\n      .bd-post h2 { font-size: 26px; margin-top: 32px; }\n      .bd-post h3 { font-size: 20px; margin-top: 24px; }\n      .bd-post .rich-multicol { grid-template-columns: 1fr; gap: 16px; padding: var(--pad-compact); }\n      .bd-post .rich-stats { padding: var(--pad-compact); }\n      .bd-post .rich-stats-num { font-size: 34px; }\n      .bd-post .bd-supply-map { padding: 8px var(--pad-compact); }\n      .bd-post .bd-supply-row { flex-wrap: wrap; gap: 6px 12px; }\n      .bd-post .bd-supply-ic { width: 32px; }\n      .bd-post .bd-supply-mid { flex: 1 1 calc(100% - 44px); }\n      .bd-post .bd-supply-chg { flex: 1 1 100%; }\n      .bd-post .bd-field-rule-quote { font-size: 19px; }\n      .bd-post .bp-cta-end { padding: var(--pad-compact); }\n      .bd-post .bp-cta-end-title { font-size: 22px; }\n      .bd-post .bp-cta-end-sub { font-size: 15px; }\n    }\n  <\/style>\n  <article class=\"bd-post-article\">\n\n    <p>La carcasa de un rel\u00e9 admite dos tensiones: \u201c24 VCC\u201d y \u201c250 VCA 10 A\u201d. La primera alimenta el rel\u00e9; la segunda es la que este conmuta. Confundirlos es el error m\u00e1s habitual con los rel\u00e9s en la pr\u00e1ctica, y acaba provocando que se queme la bobina, que el rel\u00e9 nunca se active o que haya que devolver el pedido. Esta gu\u00eda explica qu\u00e9 es la tensi\u00f3n de la bobina de un rel\u00e9, c\u00f3mo leerla en una ficha t\u00e9cnica, c\u00f3mo comprobar un rel\u00e9 que funciona mal y qu\u00e9 significa el espectro de tensiones de bobina si se almacenan rel\u00e9s al por mayor.<\/p>\n\n    <h2>Tensi\u00f3n de la bobina del rel\u00e9: qu\u00e9 significa realmente el n\u00famero que figura en la carcasa<\/h2>\n    <p>Un rel\u00e9 es un interruptor de accionamiento magn\u00e9tico. Al hacer pasar corriente por la bobina interior, esta se convierte en un electroim\u00e1n que atrae el brazo de contacto y lo cierra; al interrumpir la corriente, un resorte lo devuelve a su posici\u00f3n inicial. De ah\u00ed las dos tensiones:<\/p>\n    <ul>\n      <li><strong>Tensi\u00f3n de la bobina del rel\u00e9<\/strong> es la tensi\u00f3n que se aplica entre los terminales de la bobina para alimentar el im\u00e1n. Es el \u201ccombustible\u201d del rel\u00e9: si se le suministra una tensi\u00f3n incorrecta, no funcionar\u00e1 o, lo que es peor, puede provocar da\u00f1os.<\/li>\n      <li><strong>Capacidad de contacto<\/strong> es la tensi\u00f3n y la intensidad que los contactos pueden conmutar de forma segura una vez que la bobina se ha activado. La indicaci\u00f3n \u201c250 VCA 10 A\u201d no tiene nada que ver con la bobina.<\/li>\n    <\/ul>\n    <p>Por lo tanto, un rel\u00e9 en el que figuren ambas indicaciones necesita 24 voltios de corriente continua en su bobina y, de este modo, puede conmutar una carga de 250 VCA y 10 A a trav\u00e9s de sus contactos. Los 24 V nunca entran en contacto con la carga; los 250 V nunca entran en contacto con la bobina.<\/p>\n\n    <!-- RICH: Callout-MultiColumn -->\n    <div class=\"rich-multicol\">\n      <div>\n        <p class=\"rich-multicol-h\"><span class=\"rich-multicol-ic\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"><circle cx=\"12\" cy=\"12\" r=\"10\"\/><path d=\"M12 16v-4\"\/><path d=\"M12 8h.01\"\/><\/svg><\/span>Tensi\u00f3n de la bobina (alimenta el im\u00e1n)<\/p>\n        <p class=\"rich-multicol-p\">Valores habituales: 5, 12, 24, 48 V CC; 24, 110, 120, 220-240 V CA<\/p>\n      <\/div>\n      <div>\n        <p class=\"rich-multicol-h\">Capacidad de contacto (conmuta la carga)<\/p>\n        <p class=\"rich-multicol-p\">Valores t\u00edpicos: 250 VCA 10 A, 30 VCC 5 A. \u201c\u00bfCu\u00e1l necesito?\u201d es una pregunta sobre la bobina, no sobre los contactos.<\/p>\n      <\/div>\n    <\/div>\n\n    <p>Dos datos que debes tener en cuenta antes de seguir adelante. Las bobinas vienen en diferentes voltajes <em>versiones<\/em>: el mismo modelo b\u00e1sico se suministra con una bobina de 24 V CC, una de 12 V CC, una de 220 V CA, y as\u00ed sucesivamente. Debes adquirir la versi\u00f3n cuya bobina se ajuste a la tensi\u00f3n que puedas suministrar realmente. Este mismo concepto se aplica a los contactores, un componente similar, pero esta gu\u00eda se centra en los rel\u00e9s.<\/p>\n\n    <h2>C\u00f3mo interpretar las especificaciones de tensi\u00f3n de una bobina<\/h2>\n    <p>En la ficha t\u00e9cnica de un rel\u00e9 se indican hasta cuatro tensiones de bobina, y cada una de ellas responde a una pregunta diferente:<\/p>\n    <div class=\"table-wrapper\">\n      <table class=\"rich-table\">\n        <thead>\n          <tr><th scope=\"col\">Especificaci\u00f3n<\/th><th scope=\"col\">Lo que garantiza<\/th><th scope=\"col\">Ejemplo (bobina de 12 V CC)<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>Tensi\u00f3n nominal de la bobina<\/td><td>La referencia de dise\u00f1o para la que est\u00e1 dise\u00f1ada la bobina<\/td><td>12 V CC<\/td><\/tr>\n          <tr><td>Tensi\u00f3n m\u00ednima de funcionamiento (m\u00e1x.)<\/td><td>Por encima de esto, el rel\u00e9 <strong>debe<\/strong> atraer<\/td><td>9 V m\u00e1x. (75 % de la potencia nominal)<\/td><\/tr>\n          <tr><td>Tensi\u00f3n m\u00ednima de liberaci\u00f3n (m\u00edn.)<\/td><td>Debajo de esto, el rel\u00e9 <strong>debe<\/strong> abandonar los estudios<\/td><td>1,2 V m\u00edn. (10 % del valor nominal)<\/td><\/tr>\n          <tr><td>Tensi\u00f3n m\u00e1xima admisible en la bobina<\/td><td>Adem\u00e1s, el funcionamiento continuo conlleva el riesgo de sobrecalentamiento.<\/td><td>Espec\u00edfico de la ficha t\u00e9cnica, dependiente de la temperatura<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n    <p>La diferencia entre las filas dos y tres es la clave: entre \u00abdebe liberarse\u00bb y \u00abdebe ponerse en funcionamiento\u00bb se encuentra un <em>grupos de duraci\u00f3n indeterminada<\/em> donde el rel\u00e9 puede permanecer activado o puede conmutar, por lo que no se puede confiar en ninguna de las dos opciones. En el ejemplo anterior, ese rango va de 1,2 V a 9 V, lo que significa que el funcionamiento fiable se da por encima de los 9 V, y no en \u201ccualquier valor por debajo de 12\u201d.\u201d<\/p>\n\n    <!-- RICH: Card-Stats (\ud83d\udd16 \u8bb0\u5fc6\u94a9\u5b50\u7b7e\u540d\u5757) -->\n    <div class=\"rich-stats bd-reveal\">\n      <p class=\"rich-stats-title\"><span class=\"rich-stats-ic\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"><polyline points=\"22 7 13.5 15.5 8.5 10.5 2 17\"\/><polyline points=\"16 7 22 7 22 13\"\/><\/svg><\/span>La regla del 75 %<\/p>\n      <p class=\"rich-stats-num\">Setenta y cinco libras y tres peniques<\/p>\n      <p class=\"rich-stats-sub\">de la tensi\u00f3n nominal: el punto t\u00edpico de activaci\u00f3n obligatorio para las bobinas de rel\u00e9 de corriente continua (9 V en una bobina de 12 V, unos 18 V en una bobina de 24 V)<\/p>\n      <p class=\"rich-stats-cap\">Por debajo de ese valor, el fabricante no ofrece ninguna garant\u00eda: en la pr\u00e1ctica, el rel\u00e9 vibra o nunca se activa.<\/p>\n    <\/div>\n\n    <p>Esa cifra de 75 % es el dato m\u00e1s \u00fatil de este art\u00edculo. Una bobina de \u201c24 VCC\u201d garantiza su activaci\u00f3n a partir de unos 18-19 V (las fichas t\u00e9cnicas var\u00edan entre 70 % y 80 %), con un l\u00edmite m\u00e1ximo pr\u00e1ctico cercano a los 26 V antes de que una sobretensi\u00f3n prolongada queme la bobina. Por debajo de unos 18 V, todo es incierto. (Las bobinas de CA suelen indicar un valor de liberaci\u00f3n obligatorio m\u00e1s alto; lo habitual es 20 % de la tensi\u00f3n nominal).<\/p>\n    <p>Hay dos t\u00e9cnicas de campo que conviene tener en cuenta. En primer lugar, <strong>lee el n\u00famero de modelo<\/strong>. Los fabricantes incluyen la tensi\u00f3n de la bobina en el n\u00famero de referencia, a menudo como sufijo del modelo b\u00e1sico, por lo que, al pedir una pieza de recambio, hay que fijarse en el sufijo y no solo en el modelo b\u00e1sico. En segundo lugar, <strong>calcular a partir de la resistencia de la bobina<\/strong> con <code>V = \u221a(P \u00d7 R)<\/code>, donde las bobinas de uso general peque\u00f1as y medianas suelen consumir entre 0,45 y 0,9 W (los rel\u00e9s de potencia, hasta unos 1,9 W). Mide R, resuelve el problema, redondea al voltaje est\u00e1ndar de bobina m\u00e1s cercano y el abanico de opciones se reducir\u00e1 a una o dos; a continuaci\u00f3n, confirma con el fabricante.<\/p>\n\n    <h2>Fallos de tensi\u00f3n en la bobina del rel\u00e9: pruebas en banco para determinar la causa<\/h2>\n    <p>Cuando un rel\u00e9 \u201cdeja de funcionar\u201d, la bobina es la primera sospechosa, aunque a menudo no tiene la culpa. Dos minutos de comprobaciones en el banco de pruebas permiten distinguir entre una bobina averiada y un voltaje incorrecto:<\/p>\n\n    <!-- RICH: ComparisonTable (\u75c7\u72b6) -->\n    <div class=\"table-wrapper\">\n      <table class=\"rich-table\">\n        <caption class=\"rich-table-cap\">S\u00edntomas relacionados con la tensi\u00f3n de la bobina y su significado<\/caption>\n        <thead>\n          <tr><th scope=\"col\">S\u00edntoma<\/th><th scope=\"col\">Causa probable<\/th><th scope=\"col\">Comprobar<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>Hay tensi\u00f3n presente, por encima del umbral de activaci\u00f3n obligatoria, sin activaci\u00f3n por atracci\u00f3n<\/td><td>Circuito abierto en la bobina, o el controlador no absorbe corriente<\/td><td>Mide la resistencia de la bobina; \u00abinfinito\u00bb significa que est\u00e1 en abierto. Comp\u00e1rala con una bobina que sepas que funciona bien.<\/td><\/tr>\n          <tr><td>Chasquidos o zumbidos<\/td><td>Alimentaci\u00f3n en o por debajo de la zona de funcionamiento obligatorio; se aplica corriente alterna a una bobina de corriente continua<\/td><td>Mide la tensi\u00f3n en los terminales de la bobina bajo carga, no en la alimentaci\u00f3n.<\/td><\/tr>\n          <tr><td>Se calienta constantemente<\/td><td>Sobretensi\u00f3n, mantenida cerca o por encima de la tensi\u00f3n m\u00e1xima admisible<\/td><td>Compara la tensi\u00f3n medida con el valor m\u00e1ximo indicado en la ficha t\u00e9cnica y ajusta la potencia en funci\u00f3n de la temperatura del armario.<\/td><\/tr>\n          <tr><td>Falleci\u00f3 tras un cambio de tensi\u00f3n<\/td><td>Se ha aplicado un tipo de alimentaci\u00f3n o una tensi\u00f3n incorrectos durante el cambio<\/td><td>Vuelve a comprobar qu\u00e9 es lo que realmente alimenta la bobina, incluida la salida del controlador.<\/td><\/tr>\n          <tr><td>La bobina del aire acondicionado hace un fuerte zumbido<\/td><td>Baja tensi\u00f3n o un anillo de sombreado da\u00f1ado<\/td><td>Mide la tensi\u00f3n alterna en la bobina; 80 % de la tensi\u00f3n nominal es el m\u00ednimo pr\u00e1ctico de tensi\u00f3n alterna.<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>Esta historia cl\u00e1sica merece su propia advertencia: <strong>suministro de corriente alterna a una bobina de corriente continua<\/strong>. La corriente de una bobina de CC solo est\u00e1 limitada por la resistencia; con una corriente alterna de 50\/60 Hz, el flujo se reduce a cero dos veces por ciclo, por lo que el inducido vibra mientras la corriente alterna hace que la bobina supere su dise\u00f1o t\u00e9rmico. El resultado habitual son unos segundos de zumbido, seguidos de una bobina inservible. Lo contrario es peor, aunque de otra forma: al aplicar corriente continua a una bobina de CA se elimina la inductancia que limita su corriente, y esta aumenta hasta que la bobina se quema. \u201c24 V CA\u201d y \u201c24 V CC\u201d no son intercambiables, aunque los n\u00fameros parezcan iguales.<\/p>\n    <p>Hay un aspecto que permite evitar diagn\u00f3sticos err\u00f3neos: los contactos que no conducen la corriente no tienen por qu\u00e9 deberse necesariamente a un problema de la bobina. Si se oye c\u00f3mo se activa el inducido, la bobina est\u00e1 en buen estado. Comprueba primero la bobina y, despu\u00e9s, los contactos.<\/p>\n\n    <h2>Qu\u00e9 tensi\u00f3n de bobina utilizar: empieza por qui\u00e9n alimenta la bobina<\/h2>\n    <p>La cuesti\u00f3n de la bobina nunca es \u201c\u00bfqu\u00e9 tensi\u00f3n es la mejor?\u201d, sino \u201c\u00bfqui\u00e9n alimenta esta bobina?\u201d. La tensi\u00f3n de la bobina debe ser igual a la tensi\u00f3n de alimentaci\u00f3n de control de la que dispongas realmente, as\u00ed que mide primero la tensi\u00f3n de alimentaci\u00f3n y luego elige la bobina; nunca al rev\u00e9s.<\/p>\n\n    <h3>La bobina solo se plantea una pregunta: \u00bfqui\u00e9n la alimenta?<\/h3>\n    <!-- BP-1: \u00a74 \u4f9b\u7535\u4e16\u754c\u5bf9\u7167\u5361 (Replaces H3-1 \u56db\u60c5\u5f62\u53e5) -->\n    <div class=\"bd-supply-map bd-reveal\">\n      <div class=\"bd-supply-row\">\n        <span class=\"bd-supply-ic\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"><rect x=\"4\" y=\"4\" width=\"16\" height=\"16\" rx=\"2\"\/><rect x=\"9\" y=\"9\" width=\"6\" height=\"6\"\/><path d=\"M9 2v2\"\/><path d=\"M15 2v2\"\/><path d=\"M9 20v2\"\/><path d=\"M15 20v2\"\/><path d=\"M2 9h2\"\/><path d=\"M2 15h2\"\/><path d=\"M20 9h2\"\/><path d=\"M20 15h2\"\/><\/svg><\/span>\n        <div class=\"bd-supply-mid\"><p class=\"bd-supply-who-name\">Bobina de 24 V CC<\/p><p class=\"bd-supply-who-desc\">alimentado por la salida de un controlador (PLC, temporizador, regulador de temperatura)<\/p><\/div>\n        <p class=\"bd-supply-chg\">Corriente limitada por resistencia con un consumo constante; requiere un diodo de retorno conectado en paralelo a ella o al controlador.<\/p>\n      <\/div>\n      <div class=\"bd-supply-row\">\n        <span class=\"bd-supply-ic\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"><polygon points=\"13 2 3 14 12 14 11 22 21 10 12 10 13 2\"\/><\/svg><\/span>\n        <div class=\"bd-supply-mid\"><p class=\"bd-supply-who-name\">Bobina de CA a tensi\u00f3n de red<\/p><p class=\"bd-supply-who-desc\">se alimenta directamente de la red el\u00e9ctrica, a 110\/120 o 220\u2013240 VCA, seg\u00fan la regi\u00f3n<\/p><\/div>\n        <p class=\"bd-supply-chg\">La inductancia limita la corriente; el anillo de apantallamiento elimina el zumbido; la corriente de arranque es varias veces superior a la corriente de mantenimiento.<\/p>\n      <\/div>\n      <div class=\"bd-supply-row\">\n        <span class=\"bd-supply-ic\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"><polygon points=\"12 2 2 7 12 12 22 7 12 2\"\/><polyline points=\"2 17 12 22 22 17\"\/><polyline points=\"2 12 12 17 22 12\"\/><\/svg><\/span>\n        <div class=\"bd-supply-mid\"><p class=\"bd-supply-who-name\">Bobina universal de 24-240 V CA\/CC<\/p><p class=\"bd-supply-who-desc\">admite corriente alterna o continua en un amplio rango de frecuencias a trav\u00e9s de un rectificador interno<\/p><\/div>\n        <p class=\"bd-supply-chg\">Hay un \u00fanico modelo que cubre el rango de tensi\u00f3n de red, pero es m\u00e1s caro, se calienta m\u00e1s y no admite tensiones inferiores a 24 V.<\/p>\n      <\/div>\n      <div class=\"bd-supply-row\">\n        <span class=\"bd-supply-ic\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"><rect x=\"5\" y=\"5\" width=\"14\" height=\"14\" rx=\"2\"\/><path d=\"M9 2v3\"\/><path d=\"M15 2v3\"\/><path d=\"M9 19v3\"\/><path d=\"M15 19v3\"\/><path d=\"M2 9h3\"\/><path d=\"M2 15h3\"\/><path d=\"M19 9h3\"\/><path d=\"M19 15h3\"\/><\/svg><\/span>\n        <div class=\"bd-supply-mid\"><p class=\"bd-supply-who-name\">Entrada SSR<\/p><p class=\"bd-supply-who-desc\">alimentado por una se\u00f1al de control; sin bobina alguna<\/p><\/div>\n        <p class=\"bd-supply-chg\">Salida semiconductora en lugar de contactos; los l\u00edmites de entrada son m\u00e1s estrictos que los de una bobina.<\/p>\n      <\/div>\n    <\/div>\n\n    <h3>24 VCC: el est\u00e1ndar para los paneles de control<\/h3>\n    <p>Los armarios de PLC modernos hacen funcionar casi todos los rel\u00e9s a 24 VCC: se trata de una tensi\u00f3n de seguridad extra baja, no induce ruido en las se\u00f1ales anal\u00f3gicas cercanas como puede hacerlo el cableado de CA a tensi\u00f3n de red, y se adapta directamente a las salidas del PLC y de los sensores. Una bobina de CC es el\u00e9ctricamente sencilla; la corriente viene determinada por la resistencia, consumiendo una potencia constante y predecible. Tambi\u00e9n necesita un diodo de retorno (o el propio controlador) para absorber el pico inductivo de 100-200 V que se produce al desconectarla. El pico es normal; el da\u00f1o se produce cuando ning\u00fan diodo lo capta. Las peque\u00f1as bobinas de 5 V y 12 V pertenecen al mismo \u00e1mbito, alimentadas por fuentes integradas: misma f\u00edsica, misma regla de 75 %.<\/p>\n\n    <h3>Bobinas de tensi\u00f3n de red de CA: el mundo de la conmutaci\u00f3n directa<\/h3>\n    <p>Las bobinas de corriente alterna se fabrican de forma diferente porque la corriente alterna se comporta de manera distinta. Es la inductancia, y no la resistencia, la que limita la corriente; el flujo pasa por cero 100 o 120 veces por segundo, por lo que las bobinas de corriente alterna transportan una <em>anillo de sombreado<\/em> que mantiene el flujo residual y evita que el inducido emita un zumbido a la frecuencia de la red. La corriente de arranque es varias veces superior a la corriente de mantenimiento y, a continuaci\u00f3n, se estabiliza una vez que el inducido se cierra. A cambio, una bobina de CA no necesita alimentaci\u00f3n de CC, ni diodos, ni controlador. La tensi\u00f3n de red la activa directamente, raz\u00f3n por la cual las bobinas de 110\/120 V CA (Norteam\u00e9rica) y las de 220-240 V CA (Europa, Asia y la mayor parte del mundo) siguen predominando en m\u00e1quinas sencillas, bombas y equipos antiguos.<\/p>\n    <p>La subtensi\u00f3n es m\u00e1s insidiosa en la corriente alterna: una bobina de 220 VCA alimentada por un circuito de 208 V se encuentra cerca de su umbral m\u00ednimo de 80 %, lo que implica una activaci\u00f3n marginal y un exceso de calor. Si la tensi\u00f3n en tu instalaci\u00f3n es baja, m\u00eddela antes de culpar al rel\u00e9.<\/p>\n\n    <img decoding=\"async\" src=\"https:\/\/www.omch.com\/wp-content\/uploads\/2026\/09\/Relay-Coil.webp\" style=\"width: 512px; height: 384px; max-width: 100%; object-fit: cover; border-radius: 12px; margin: 30px auto; display: block; box-shadow: 10px 10px 60px 0px rgba(210, 221, 224, 0.35); transition: all 0.3s ease; cursor: pointer;\" onmouseover=\"this.style.transform='translateY(-5px) scale(1.03)'; this.style.boxShadow='15px 25px 80px 0px rgba(210, 221, 224, 0.45)'\" onmouseout=\"this.style.transform='translateY(0) scale(1)'; this.style.boxShadow='10px 10px 60px 0px rgba(210, 221, 224, 0.35)'\"> \n\n    <h3>Entradas universales y de estado s\u00f3lido: los extremos modernos del espectro<\/h3>\n    <p>Hay dos plantas que est\u00e1n creciendo en los bordes. <strong>Bobinas universales<\/strong>, que suelen llevar la indicaci\u00f3n \u201c24\u2013240 V CA\/CC\u201d, contienen un peque\u00f1o rectificador interno y admiten casi cualquier tensi\u00f3n de control dentro de un amplio rango, ya sea CA o CC. Una sola referencia cubre todo el \u00e1mbito de la tensi\u00f3n de red, raz\u00f3n por la cual a los distribuidores les est\u00e1n empezando a encantar y los t\u00e9cnicos se preguntan c\u00f3mo funcionan. Las desventajas: son m\u00e1s caras, generan m\u00e1s calor propio (los componentes electr\u00f3nicos internos est\u00e1n siempre alimentados) y no cubren el rango de baja tensi\u00f3n de CC por debajo de unos 24 V. Reducen las variaciones de tensi\u00f3n en el stock, pero no las eliminan.<\/p>\n    <p><strong>Entradas SSR<\/strong> En el otro extremo: sin bobina, sin piezas m\u00f3viles, solo un circuito de entrada (normalmente de 3 a 32 V CC o de 24 a 280 V CA) que controla una salida de semiconductores. A menudo, esta es la soluci\u00f3n m\u00e1s sencilla para un PLC que conmuta una carga pesada, pero los requisitos de entrada son m\u00e1s estrictos, por lo que la selecci\u00f3n debe realizarse siguiendo criterios diferentes.<\/p>\n    <p><strong>La temperatura del armario es la variable oculta.<\/strong> La resistencia del cobre aumenta a medida que la bobina se calienta, la corriente disminuye para una misma tensi\u00f3n aplicada y el margen por encima del umbral de activaci\u00f3n se reduce. Un rel\u00e9 que se activa a 20 \u00b0C puede quedarse inactivo y emitir un zumbido a 60 \u00b0C en un armario cerrado con una alimentaci\u00f3n el\u00e9ctrica inestable. La soluci\u00f3n pasa por una tensi\u00f3n de alimentaci\u00f3n estable y la ventilaci\u00f3n del armario, no por un rel\u00e9 \u201cm\u00e1s potente\u201d.<\/p>\n\n    <h2>Tensi\u00f3n de la bobina seg\u00fan la aplicaci\u00f3n: una matriz de campos<\/h2>\n    <p>La tabla que aparece a continuaci\u00f3n es el resultado pr\u00e1ctico de todo lo expuesto anteriormente: una lista de comprobaci\u00f3n por escenario que puedes consultar al lado de un pedido real.<\/p>\n\n    <!-- RICH: ComparisonTable (\u573a\u666f\u77e9\u9635) -->\n    <div class=\"table-wrapper\">\n      <table class=\"rich-table\">\n        <caption class=\"rich-table-cap\">Tensi\u00f3n de la bobina seg\u00fan la aplicaci\u00f3n<\/caption>\n        <thead>\n          <tr><th scope=\"col\">Aplicaci\u00f3n<\/th><th scope=\"col\">Elecci\u00f3n del lado de la bobina<\/th><th scope=\"col\">Par\u00e1metros que hay que comprobar<\/th><th scope=\"col\">En qu\u00e9 falla<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>Armario de PLC o de control<\/td><td>Bobina de 24 V CC compatible con la salida del controlador<\/td><td>Debe funcionar \u2264 75 %; tensi\u00f3n de alimentaci\u00f3n medida en la bobina bajo carga; diodo de retorno instalado<\/td><td>La tensi\u00f3n del ra\u00edl de 24 V desciende por debajo de unos 18-19 V; al no haber diodo de retorno, el controlador deja de funcionar<\/td><\/tr>\n          <tr><td>Conmutaci\u00f3n directa a tensi\u00f3n de red<\/td><td>Bobina de CA a la tensi\u00f3n de red local (110-120 o 220-240 VCA)<\/td><td>Tensi\u00f3n de red medida in situ; disparo obligatorio de CA (a menudo 20 %); sin zumbido procedente del anillo de sombreado<\/td><td>Tensi\u00f3n de conexi\u00f3n baja, cercana a 80 % del valor nominal; la aplicaci\u00f3n de corriente continua a una bobina de corriente alterna provoca una sobrecorriente<\/td><\/tr>\n          <tr><td>Sustituci\u00f3n de m\u00e1quinas antiguas<\/td><td>Sustit\u00fayela por una bobina con la MISMA tensi\u00f3n que la original.<\/td><td>Antes de comprarlo, f\u00edjate en la inscripci\u00f3n de la bobina del rel\u00e9 antiguo o en el sufijo del modelo.<\/td><td>\u201cAumentar\u201d la tensi\u00f3n de la bobina sin comprobar el circuito, que sigue suministrando la tensi\u00f3n anterior<\/td><\/tr>\n          <tr><td>Equipos para exportaci\u00f3n \/ multirregionales<\/td><td>Tensi\u00f3n de la bobina por zona de destino (110-120 VCA en Norteam\u00e9rica, 220-240 VCA en el resto del mundo, 24 VCC en los paneles)<\/td><td>Confirma la regi\u00f3n de destino; una variante universal de 24-240 V CA\/CC es v\u00e1lida para flotas mixtas<\/td><td>Almacenar productos con una tensi\u00f3n de red y enviarlos a la regi\u00f3n equivocada<\/td><\/tr>\n          <tr><td>Un relevo desconocido en el banquillo<\/td><td>Realizar ingenier\u00eda inversa antes de la puesta en marcha (m\u00e9todo de la resistencia)<\/td><td>Resistencia de la bobina; potencia estimada: 0,45-0,9 W; redondear a una tensi\u00f3n est\u00e1ndar<\/td><td>Calcular la tensi\u00f3n nominal: medir y, a continuaci\u00f3n, ajustar<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>Tres campos que hay que confirmar antes de cada pedido: <strong>tensi\u00f3n de la bobina y tipo de alimentaci\u00f3n, por separado<\/strong>, ya que la indicaci\u00f3n \u201c24 V\u201d no es completa y las bobinas de 24 VCA y 24 VCC fallan de forma diferente; <strong>capacidad de contacto, independientemente de la bobina<\/strong>, porque la carga determina una cosa y la fuente de alimentaci\u00f3n, la otra; y <strong>margen de temperatura ambiente<\/strong>, ya que en una cabina caliente el suministro debe seguir funcionando correctamente con la bobina caliente.<\/p>\n    <p>La mayor\u00eda de los errores al sustituir una pieza se deben a que se pide el modelo b\u00e1sico sin leer la referencia de la pieza que se va a sustituir. Lee primero la referencia de la pieza antigua.<\/p>\n\n    <!-- BP-2: \u00a75 \u94c1\u5f8b\u5f15\u53e5 (Replaces \u6bb5\u9996\u53e5) -->\n    <div class=\"bd-field-rule\">\n      <span class=\"bd-field-rule-label\">Regla de campo<\/span>\n      <p class=\"bd-field-rule-quote\">La tensi\u00f3n de la bobina de recambio es igual a la de la original.<\/p>\n    <\/div>\n\n    <h2>El aspecto comercial: la gesti\u00f3n del espectro de voltajes de las bobinas<\/h2>\n    <p>Todo lo anterior tiene su lado comercial, y para los distribuidores eso lo es todo: un rel\u00e9 no es un \u00fanico producto, sino una familia de versiones con diferentes tensiones de bobina bajo un mismo modelo b\u00e1sico. El cliente que llama para preguntar por un rel\u00e9 mencionar\u00e1 la tensi\u00f3n de la bobina en la primera frase. Es entonces cuando la gama de productos deja de ser un mero concepto de la ficha t\u00e9cnica.<\/p>\n\n    <h3>La unidad m\u00ednima para el presupuesto es \u201cmodelo + tensi\u00f3n de la bobina\u201d.\u201d<\/h3>\n    <p>Presentar un presupuesto para un modelo b\u00e1sico sin especificar la versi\u00f3n de la bobina es como no presentar nada. El circuito del cliente ya ha determinado la respuesta, y un voltaje de bobina incorrecto implica una devoluci\u00f3n, un nuevo env\u00edo y un cliente que consultar\u00e1 primero el siguiente cat\u00e1logo. Hay dos h\u00e1bitos que cierran el c\u00edrculo: haz que el voltaje de la bobina y el tipo de alimentaci\u00f3n (CA o CC) sean campos obligatorios en tus formularios de presupuesto, y ense\u00f1a a quien atienda el tel\u00e9fono a preguntar por la versi\u00f3n de la bobina cuando un cliente le lea el n\u00famero de modelo.<\/p>\n\n    <h3>Dos l\u00edneas de volumen paralelas, y qu\u00e9 bobinas universales cambian<\/h3>\n    <p>Desde el punto de vista de un distribuidor, el espectro cuenta con dos l\u00edneas de volumen. El <strong>L\u00ednea de 24 VCC<\/strong> es el material de consumo por excelencia del mundo de los PLC y los DCS; cada reconstrucci\u00f3n de armario y cada modernizaci\u00f3n de panel los consume. El <strong>tensi\u00f3n de red de CA<\/strong> (110\/120 VCA en Norteam\u00e9rica, 220-240 VCA en el resto del mundo) es el consumible de las m\u00e1quinas con conmutaci\u00f3n directa y de una amplia base instalada que a\u00fan recibe servicio t\u00e9cnico. Tener en stock \u00fanicamente 24 VCC supone ceder silenciosamente todas las consultas sobre tensi\u00f3n de red a quien tenga en stock ambas tensiones. A <strong>bobina universal de 24-240 V CA\/CC<\/strong> Reduce la gama de productos del lado de CA: una sola referencia sustituye a la mayor\u00eda de las variantes de tensi\u00f3n de red de baja rotaci\u00f3n, pero no sustituye al lado de CC, ya que por debajo de unos 24 V no existe una opci\u00f3n universal. La gama pr\u00e1ctica: 24 V CC en profundidad, una peque\u00f1a gama universal para el mundo de la tensi\u00f3n de red y variantes de 5\/12 V CC para los dispositivos electr\u00f3nicos que fabrican tus clientes. Mide el stock por <em>cobertura del espectro<\/em>, y no el n\u00famero de modelos: diez modelos en una banda de tensi\u00f3n responden a un tipo de consulta; cinco modelos repartidos por todo el espectro responden a la mayor\u00eda de ellas.<\/p>\n    <p>A la hora de evaluar a un proveedor de rel\u00e9s, a\u00f1ade el par\u00e1metro de tensi\u00f3n de la bobina a la lista de comprobaci\u00f3n: \u00bfen qu\u00e9 versiones de tensi\u00f3n de bobina est\u00e1 disponible cada familia de rel\u00e9s?, \u00bfc\u00f3mo se codifica la tensi\u00f3n de la bobina en el n\u00famero de modelo? y \u00bfse puede obtener una ficha t\u00e9cnica para cada versi\u00f3n de bobina, y no solo para cada familia? OMCH\u2019s <a href=\"https:\/\/www.omch.com\/es\/relay\/\">p\u00e1ginas de la familia Relay<\/a> enumerar las familias que ofrecemos, y <a href=\"https:\/\/www.omch.com\/es\/product-selection\/\">nuestro servicio de selecci\u00f3n de productos<\/a> Para eso est\u00e1 precisamente: env\u00edanos el n\u00famero de modelo y la tensi\u00f3n de la bobina que necesita tu circuito, y te confirmaremos la versi\u00f3n adecuada y su ficha t\u00e9cnica antes de que te comprometas, de modo que la regla 75 %, el sufijo y el rango de tensi\u00f3n queden claros por escrito, y no se descubran una vez que haya llegado el rel\u00e9.<\/p>\n    <p><em>Si vas a sustituir rel\u00e9s en un cuadro el\u00e9ctrico o los est\u00e1s almacenando para clientes que vayan a hacerlo, <a href=\"https:\/\/www.omch.com\/es\/contact\/\">ponte en contacto con nosotros<\/a>. Te ayudaremos a encontrar los voltajes de bobina adecuados en las familias de rel\u00e9s que tenemos en stock, modelo por modelo.<\/em><\/p>\n\n    <!-- BP-cta-end -->\n    <div class=\"bp-cta-end bd-reveal\">\n      <div class=\"bp-cta-end-inner\">\n        <p class=\"bp-cta-end-title\"><span class=\"bp-cta-end-ic\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"><path d=\"M22 2 11 13\"\/><path d=\"M22 2l-7 20-4-9-9-4 20-7\"\/><\/svg><\/span>Env\u00edanos el n\u00famero de modelo y la tensi\u00f3n de la bobina<\/p>\n        <p class=\"bp-cta-end-sub\">Antes de que te decidas, verificamos que la versi\u00f3n del rel\u00e9 y su ficha t\u00e9cnica coincidan con las de las familias que tenemos en stock.<\/p>\n        <a class=\"bp-cta-end-btn\" href=\"https:\/\/www.omch.com\/es\/contact\/\" target=\"_self\">Comprueba el voltaje de mi bobina<span class=\"bp-cta-end-arrow\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a>\n      <\/div>\n    <\/div>\n\n    <h2>Referencias<\/h2>\n    <ol>\n      <li><a href=\"https:\/\/ac-blog.panasonic.com\/relay\/introduction-to-relays-relay-terminology-operating-coil\" target=\"_blank\" rel=\"noopener\">Panasonic Industry. \u201cIntroducci\u00f3n a los rel\u00e9s \u2014 Terminolog\u00eda de los rel\u00e9s: bobina de accionamiento\u201d.\u201d<\/a> 2020.<\/li>\n      <li><a href=\"https:\/\/components.omron.com\/us-en\/faq\/relays\/FAQE10015\" target=\"_blank\" rel=\"noopener\">Omron Components. \u201cC\u00f3mo interpretar la tensi\u00f3n de funcionamiento, la tensi\u00f3n de liberaci\u00f3n y la tensi\u00f3n m\u00e1xima\u201d.\u201d<\/a> 2021.<\/li>\n      <li><a href=\"https:\/\/www.te.com\/en\/products\/relays-and-contactors\/electromechanical-relays\/intersection\/coil-voltage-temperature-compensation.html\" target=\"_blank\" rel=\"noopener\">TE Connectivity. \u201cCompensaci\u00f3n de tensi\u00f3n y temperatura de la bobina\u201d.\u201d<\/a><\/li>\n      <li><a href=\"https:\/\/stoklink.com\/blogs\/technical\/relay-coil-voltages-24vdc-110vac-230vac\" target=\"_blank\" rel=\"noopener\">Stoklink. \u201cTensiones de las bobinas de rel\u00e9: 24 V CC frente a 110 V CA frente a 230 V CA\u201d.\u201d<\/a> 2026.<\/li>\n      <li><a href=\"https:\/\/hwrelay.com\/how-do-i-know-which-coil-voltage-to-choose-for-a-power-relay-switch\/\" target=\"_blank\" rel=\"noopener\">Hwrelay. \u201cC\u00f3mo seleccionar la tensi\u00f3n de bobina de un rel\u00e9 de potencia\u201d.\u201d<\/a> 2025.<\/li>\n      <li><a href=\"https:\/\/forum.digikey.com\/t\/understanding-relay-coil-voltage-specifications\/946\" target=\"_blank\" rel=\"noopener\">Foro de DigiKey. \u201cC\u00f3mo entender las especificaciones de tensi\u00f3n de la bobina de un rel\u00e9\u201d.\u201d<\/a> 2017.<\/li>\n      <li><a href=\"https:\/\/www.reddit.com\/r\/PLC\/comments\/1ew2m16\/what_happens_when_ac_power_is_applied_to_the_dc\/\" target=\"_blank\" rel=\"noopener\">Reddit r\/PLC. \u201c\u00bfQu\u00e9 ocurre cuando se aplica corriente alterna a la bobina de corriente continua de un rel\u00e9?\u201d<\/a> 2024.<\/li>\n      <li><a href=\"https:\/\/www.reddit.com\/r\/AskElectronics\/comments\/1v8xixd\/for_a_small_power_relay_does_reducing_coil\/\" target=\"_blank\" rel=\"noopener\">Reddit r\/AskElectronics. \u201cEn un rel\u00e9 de baja potencia, \u00bfafecta a su funcionamiento la reducci\u00f3n de la tensi\u00f3n de la bobina?\u201d<\/a> 2026.<\/li>\n      <li><a href=\"https:\/\/www.omch.com\/es\/relay\/\" target=\"_blank\" rel=\"noopener\">OMCH. \u201cRel\u00e9s: familias de productos\u201d.\u201d<\/a><\/li>\n      <li><a href=\"https:\/\/www.omch.com\/es\/product-selection\/\" target=\"_blank\" rel=\"noopener\">OMCH. \u201cServicio de selecci\u00f3n de productos\u201d.\u201d<\/a><\/li>\n      <li><a href=\"https:\/\/www.omch.com\/es\/contact\/\" target=\"_blank\" rel=\"noopener\">OMCH. \u201cContacto\u201d.\u201d<\/a><\/li>\n      <li><a href=\"https:\/\/www.omch.com\/es\/\" target=\"_blank\" rel=\"noopener\">OMCH. \u201cInicio\u201d.\u201d<\/a><\/li>\n    <\/ol>\n\n  <\/article>\n<\/div>\n<!-- \u2191\u2191\u2191 Fragment ends here. \u2191\u2191\u2191 -->\n<\/body><\/html>","protected":false},"excerpt":{"rendered":"<p>Explicaci\u00f3n del voltaje de la bobina de un rel\u00e9: qu\u00e9 significa la cifra que aparece en la carcasa (y c\u00f3mo hacer coincidir los valores). La carcasa de un rel\u00e9 indica dos voltajes: \u201c24 VCC\u201d y \u201c250 VCA 10 A\u201d. El primero alimenta el rel\u00e9; el segundo es el que este conmuta. Confundirlos es el error m\u00e1s habitual con los rel\u00e9s en la pr\u00e1ctica, y acaba provocando que se queme [\u2026]<\/p>","protected":false},"author":4,"featured_media":12232,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"Relay Coil Voltage: How to Choose and Match It","_seopress_titles_desc":"Learn how relay coil voltage works, read AC\/DC ratings, diagnose undervoltage and choose the correct replacement.","_seopress_robots_index":"","footnotes":""},"categories":[79],"tags":[],"class_list":["post-12233","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mmlblog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/posts\/12233","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/comments?post=12233"}],"version-history":[{"count":1,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/posts\/12233\/revisions"}],"predecessor-version":[{"id":12236,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/posts\/12233\/revisions\/12236"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/media\/12232"}],"wp:attachment":[{"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/media?parent=12233"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/categories?post=12233"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.omch.com\/es\/wp-json\/wp\/v2\/tags?post=12233"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}