We deliver expert services, from supply chain integration and product selection to customization and comprehensive technical support, ensuring your automation success.


1. Before use, carefully inspect the components for any damage that may have occurred during shipping, then install and use them;
2. During installation, ensure the gas flow direction and the thread type of the connecting pipes are correct. The working fluid must be filtered through a 40-micron filter element;
etc.), then install and use them;
3. Ensure that the installation conditions meet the technical requirements (such as “voltage,” “operating frequency,” “operating pressure,” and “operating temperature range”
5. Avoid using the unit in vibrating environments whenever possible, and take precautions against freezing at low temperatures;
4. During installation, pay attention to the direction of gas flow: P is the inlet, A (B) is the working port, and R (S) is the exhaust port;
Dirt—prevent impurities or foreign objects from entering the valve body; sleeve.
6. When connecting piping, ensure that the sealing tape is not wrapped beyond the end face of the fitting threads, and be sure to remove dust, metal shavings, and other debris from the pipe fittings;
7. Take precautions against dust; it is recommended to install a silencer or a silencer-throttling valve on the exhaust port. When the unit is disassembled and not in use, install dust covers on the inlet and outlet ports;
8. During commissioning of the entire unit, it is recommended to first perform testing using the manual operation mechanism, and then proceed with powered operation.
Specification | 3V110-M5 | 3V120-M5 | 3V110-06 | 3V120-06 |
Working Medium | Air (Filtered through a 40 μm filter) | |||
Operation Type | Internal Pilot or External Pilot | |||
Port Size | M5 | M5 | PT1/8 | PT1/8 |
Effective Orifice Area (Cv) | 10.2 mm² (Cv = 0.6) | 10.2 mm² (Cv = 0.6) | 10.2 mm² (Cv = 0.6) | 10.2 mm² (Cv = 0.6) |
Valve Positions | 2 Positions, 3 Ways | |||
Lubrication | Not Required | |||
Operating Pressure Range | 0.15–0.8 MPa (21–114 psi) | |||
Maximum Pressure Resistance | 1.2 MPa (175 psi) | |||
Operating Temperature | −20 to +70°C | |||
Body Material | Aluminum Alloy | |||
We don't just limit ourselves to standard products; if your industry or project requires customized solutions, we are here to meet your needs.
You can reach out to us for consultation or provide your product specifications, and we will help you precisely identify the most suitable industrial automation products.
We also offer comprehensive after-sales services and technical support to ensure the best possible protection for every order you place.